Extreme Networks AG200 manual Sentriant AG Appliance Technical Specifications

Page 35

B Technical Specifications

Table 4 provides technical specifications for the Sentriant AG200 appliance.

Table 4: Sentriant AG Appliance Technical Specifications

Physical Specifications

 

Chassis dimensions

Height: 1.7 inches (4.3 cm)

 

Width: 17 inches (43.2 cm)

 

Depth: 17.3 inches (43.9 cm)

Weight

21 lb (9.5 kg)

Power Input

 

Voltage ranging

90-254 V AC

Nominal voltage range:

100-240 V AC

Line frequency range

47-63 Hz

Maximum input current

2.4A @ 100 V AC

 

1.2A @ 200 V AC

Power Cord

 

 

North America power supply cord provided with equipment.

 

Power supply cords used outside the US require country-specific certifications

 

as required by country standards.

Input socket

IEC 60320 C13

Wire size

0.75 mm2 (18 AWG) copper stranded

Maximum length

10 ft (3.05 m)

Safety Standards

 

North American Safety of ITE

ULus Listed Device UL 60950-1:2003 1st Edition

 

cUL to CSA C22.2 No.60950-1-03 1st Edition

European Safety of ITE

73/23/EEC Low Voltage Directive (LVD)

 

EN60950-1:2001+A11

 

TUV-R GS Mark

 

DEMKO

International Safety of ITE

IEC 60950-1:2001 1st Edition with all applicable country deviations

 

ANATEL, Safety Resolution 238 (Brazil)

 

NOM/NYCE (Mexico)

EMI/EMC Standards

 

North American EMC for ITE

FCC 47 CFR Part 15, Subpart B, Class A

 

ICES-003, Class A

Sentriant AG200 Hardware Installation Guide

35

 

 

Image 35
Contents Sentriant AG200 Hardware Installation Guide Sentriant AG200 Hardware Installation Guide Contents Index Conventions PrefaceAbout this Guide Organization of this GuideText Conventions Related PublicationsChassis Overview Front Panel FeaturesAbout the Sentriant AG200 Appliance LED Operation Back Panel FeaturesLCD Panel About the Sentriant AG200 Appliance Rack Ventilation Requirements Site Preparation and UnpackingSite Requirements for the Sentriant AG Appliance Unpacking the Sentriant AG Appliance Attaching the Rack-Mount Brackets Installing the Sentriant AG200 ApplianceOverview Required Tools and EquipmentInstalling the Sentriant AG200 Appliance Installing the Sentriant AG Appliance in a RackConnecting Cables Connecting PowerInstalling the Sentriant AG200 Appliance Using Console Menus Startup and ConfigurationConnecting to the Console Port Configuring Network Settings Performing the Initial SetupSetting the Time, Date, and Time Zone Startup and Configuration Sentriant AG200 Hardware Installation Guide Setting the Operation Mode of the Server Security Alert Window Initial ConfigurationEnter Management Server Settings Window Enter License Key Window Sentriant AG Home Window Enabling LAN BypassSelect Onboard Devices Startup and Configuration Power Safety Safety InformationConsiderations Before Installing General Safety Precautions Maintenance SafetyBattery Replacement and Disposal Sicherheitshinweise Hinweise zur InstallationAllgemeine Sicherheitsmaßnahmen WartungssicherheitAustauschen und Entsorgen von Batterien Sentriant AG Appliance Technical Specifications Technical SpecificationsTechnical Specifications Sentriant AG Appliance Technical Specifications Technical Specifications Index Index