If the actual test levels are higher or different than required, these levels are listed in the appropriate tables.
EN 55022 Class B (1994 w/A1 1995)
| Test | Specification | Requirement | 
| 
 | EN55024 | 
 | 
| 
 | 
 | 
 | 
| Electrostatic | +4 kV contact | |
| Discharge | 
 | +8kV air | 
| Radiated | 3 V/m | |
| Immunity | 
 | 
 | 
| 
 | 
 | 
 | 
| Electrical Fast | 1kV (A/C), .5kV (I/O) | |
| Transient Burst | 
 | 
 | 
| 
 | 
 | 
 | 
| Surge | 2kV common mode | |
| 
 | 
 | 1kV differential mode | 
| Conducted | 3V rms | |
| Immunity | 
 | 
 | 
| Magnetic | 1 A/m Not Applicable | |
| Immunity | 
 | 
 | 
| 
 | 
 | 
 | 
| Voltage Dips & | >95%, 30% & >95% | |
| Interrupts | 
 | 
 | 
EN55024 (1998)
| Test | Specification | Requirement | 
| 
 | EN55022 | 
 | 
| 
 | 
 | 
 | 
| Radiated | — | Class B | 
| Emissions | 
 | 
 | 
| Conducted | CISPR 22 | Class B | 
| Emissions | 
 | 
 | 
| 
 | 
 | 
 | 
Digi International
11001 Bren Road East
Minnetonka, MN 55343
digi.info@digi.com
www.digi.com
Corporate Headquarters:
Digi Europe: 
Digi Hong Kong: 
Digi North America: 
European Contact
Digi International 
UL/CSA Safety Information
This device complies with the requirements of following safety standards below:
UL 1950, 3rd edition
CSA No. 950
Quality Manager
Austin, Texas
February 2006