Digi MIL-4511H Description of Hardware, Description of the LEDs, Description of Dip Switches

Page 3

Install Guide

Description of Hardware

The MIL-4511H is a 24-port, 10BASE-T SNMP managed hub with a modular uplink port supporting 10BASE-T, 10BASE2, 10BASE-BASE-FL, or AUI connectivity, and an RS-232 port for out-of-band management. The MIL-4511H supports standard MIB-II, Digi's private MIB, and MIBs using the SNMP protocol with both in-band management (over TCP/IP and IPX protocols) and out-of-band management through an RS-232 port. Each of the 10BASE-T ports support LinkSentry™. LinkSentry alerts the user if or when there is a link failure.

Description of the LEDs

On the front panel of the MIL-4511H, there is one LED above each of the RJ-45 ports. The LED lights in one of three colors to indicate the following:

Green indicates link present

Orange indicates that the device is receiving data

Red indicates that the port is partitioned

Also on the front panel are three LEDs located between the Stack In/ Out ports and the first RJ-45 port. They indicate the following:

PWR (Power): This LED illuminates when power is applied to the device

MBUS (Management Bus): This LED blinks when activity from the agent is in progress (only for the MIL-4511H).

MSYS (Management System): This LED blinks five times per second until the agent is found. Once found, it blinks once per second (only for the 4511H).

On both sides of the second group of eight Ports on the front panel are two global LEDs. The global RX LED lights when a port is receiving a data packet. The global CX LED lights when a collision occurs on one of the ports.

Description of Dip Switches

To the right of the DB-9 Serial Port on the rear of the hub are two Dip Switches (labeled 1 and 2). The following table gives the function of the two Dip Switches

ON

12

D1

D2

FUNCTION

 

 

 

 

 

 

Off (Up)

Off (Up)

Normal Mode (Telnet Disabled)

On (Down)

Off (Up)

Normal Mode (Telnet Enabled)

On (Down)

On (Down)

Monitor Mode, SNMP (Agent not Operational)

Model: MIL-4511H

3

Image 3
Contents MIL-4511H Micro Modules used with the MIL 4511H MIL 4511H Packag e ContentsDescription of Dip Switches Description of HardwareDescription of the LEDs Installation Procedure Installation of Micro ModulesDB 9 Serial Por t MIL4511 Model Installation of the Rubber FeetStacking Multiple Hubs Installation of the Interconnect CablePor t Redundancy Cascading HubsAssigning an IP Address Arpbypass set alpha 0x00.0x40.0xc8.0x00.0x01.0x2B Setting the IP Address with TelnetAlpha Arp -s ether alpha 040c80012BUsr/etc/rarpd-a or /etc/rarpd-a Setting the IP Address with RarpSetting the IP Address with Bootp 0040c802abcdalphaTo set the IP Address with Bootp on a HP/UX system Hostname of MIL-4511Hht=1ha=hardware addressip=ip addressAlphaht=1ha=0040c8010203ip=199.86.12.183 Ping ip-address Verifying the IP Address is Set ProperlyPing hostname Alpha is aliveLegal Five-Year Limited Warranty