Thermal Resistance
In this table, the thermal resistance parameters are listed.[3]
Parameter | Description | Test Conditions | 
 | 
 | Unit | 
ΘJA  | Thermal Resistance  | Test conditions follow standard test methods and proce-  | TBD  | TBD  | °C/W  | 
  | (Junction to Ambient)  | dures for measuring thermal impedance, per EIA /  | 
  | 
  | 
  | 
  | 
  | JESD51.  | 
  | 
  | 
  | 
ΘJC  | Thermal Resistance  | TBD  | TBD  | °C/W  | |
  | (Junction to Case)  | 
  | 
  | 
  | 
  | 
  | 
  | Figure 5. AC Test Loads | 
  | 
  | 
  | 
R1 480Ω
5.0V  | 
Output  | 
30 pF  | 
  | R2  | 
  | ||
  | 
  | 
255Ω
AC Test Conditions
Input Pulse Levels  | 0V to 3V  | 
Input Rise and Fall Times (10% to 90%)  | <5 ns  | 
Input and Output Timing Reference Levels  | 1.5V  | 
Document Number:   | Page 6 of 15  | 
[+] Feedback