Maximum Ratings
Exceeding maximum ratings may shorten the useful life of the device. These user guidelines are not tested.
Storage Temperature | |
Temperature under bias | |
Supply Voltage on VCC Relative to GND | |
Voltage on Input Relative to Vss |
Voltage on | |
Power Dissipation | 1.0W |
DC Output Current (1 output at a time, 1s duration).... 15 mA
Operating Range
Range | Ambient | VCC |
Temperature | ||
Military | 4.5V to 5.5V | |
|
|
|
DC Electrical Characteristics
Over the operating range (VCC = 4.5V to 5.5V)
Parameter | Description |
|
|
|
|
|
|
|
|
|
|
|
| Test Conditions |
|
|
|
|
| Min | Max | Unit | ||||||||
ICC1 | Average VCC Current |
| tRC | = 35 ns |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 75 | mA | ||||||||
|
|
|
| tRC | = 45 ns |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 65 | mA | |||||||
|
|
|
| tRC | = 55 ns |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 55 | mA | |||||||
|
|
|
| Dependent on output loading and cycle rate. Values obtained |
|
|
| |||||||||||||||||||||||
|
|
|
| without output loads. IOUT = 0 mA |
|
|
|
|
|
|
|
| ||||||||||||||||||
ICC2 | Average VCC Current |
| All Inputs Do Not Care, VCC = Max |
|
|
|
|
|
| 3 | mA | |||||||||||||||||||
|
| during STORE |
| Average current for duration tSTORE |
|
|
|
|
|
|
|
| ||||||||||||||||||
ICC3 | Average VCC Current at |
|
|
|
|
| > (V | – 0.2V). All other inputs cycling. |
|
|
|
|
|
| 10 | mA | ||||||||||||||
| WE |
|
|
|
|
|
| |||||||||||||||||||||||
|
| tRC= 200 ns, 5V, 25°C |
|
|
|
|
|
| CC |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Dependent on output loading and cycle rate. Values obtained |
|
|
| ||||||||||||||||||||||||
|
| Typical |
| without output loads. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
I | [2] | VCC Standby Current |
| t |
|
|
| = 35 ns, |
| > V |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 24 | mA | |||
| RC | CE | IH |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
SB1 | (Standby, Cycling TTL |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 21 | mA | ||||||
|
|
| tRC = 45 ns, CE > VIH |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
| Input Levels) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| 20 | mA | ||||||||||||
|
|
| tRC = 55 ns, CE > VIH |
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||||
I |
| VCC Standby Current |
| CE > (V | – 0.2V). All others V |
|
| < 0.2V or > (V – 0.2V). |
| 1500 | A | |||||||||||||||||||
| [2] |
|
|
|
|
|
|
| CC |
|
|
|
|
|
|
|
| IN |
|
|
|
| CC |
|
|
| μ | |||
SB2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||
|
|
|
| Standby current level after nonvolatile cycle is complete. |
|
|
|
| ||||||||||||||||||||||
|
|
|
| Inputs are static. f = 0 MHz |
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
IIX |
| Input Leakage Current | VCC = Max, VSS < VIN < VCC |
|
|
|
|
|
|
|
|
|
| +1 | μA | |||||||||||||||
IOZ |
| Off State Output |
| V |
|
|
| = Max, V | < V |
| < V , |
|
| or |
| > V |
| or |
| < V |
| +5 | μA | |||||||
|
| CC | IN | CE | OE | IH | WE | IL | ||||||||||||||||||||||
|
| Leakage Current |
|
|
|
|
| SS |
|
| CC |
|
|
|
|
|
|
|
|
|
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
VIH |
| Input HIGH Voltage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2.2 | VCC + 0.5 | V |
VIL |
| Input LOW Voltage |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| VSS – 0.5 | 0.8 | V |
VOH | Output HIGH Voltage |
| IOUT = |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 2.4 |
| V | |||||||||
VOL |
| Output LOW Voltage |
| IOUT = 8 mA |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| 0.4 | V |
Data Retention and Endurance
Parameter | Description | Min | Unit |
DATAR | Data Retention | 100 | Years |
NVC | Nonvolatile STORE Operations | 1,000 | K |
Capacitance
In this table, the capacitance parameters are listed.[3]
Parameter | Description | Test Conditions | Max | Unit |
CIN | Input Capacitance | TA = 25°C, f = 1 MHz, | 8 | pF |
|
| VCC = 0 to 3.0V |
|
|
COUT | Output Capacitance | 7 | pF |
Note
2.CE > VIH does not produce standby current levels until any nonvolatile cycle in progress has timed out.
3.These parameters are guaranteed by design and are not tested.
Document Number: | Page 5 of 15 |