Dell 8100 manual Pvid and native Vlan, Cat6504E1config-if#spanning-tree portfast edge

Page 11

Deploying the Dell PowerConnect 8100 with the Cisco Catalyst

Cat6504E_1(config)#interface te2/7

Cat6504E_1(config-if)#switchport

Cat6504E_1(config-if)#switchport access vlan 100

Cat6504E_1(config-if)#switchport mode access

Cat6504E_1(config-if)#spanning-tree portfast edge

Cat6504E_1(config-if)#no shutdown

Cat6504E_1(config-if)#exit

Cat6504E_1(config)#interface te2/8

Cat6504E_1(config-if)#switchport

Cat6504E_1(config-if)#switchport access vlan 101

Cat6504E_1(config-if)#switchport mode access

Cat6504E_1(config-if)#spanning-tree portfast edge

Cat6504E_1(config-if)#no shutdown

Cat6504E_1(config-if)#exit

PVID and native VLAN

Port VLAN ID (PVID) and native VLANs are considered by many to be the same thing. Every physical switching port on the switch has a VLAN ID, which equates to the PVID. When untagged frames ingress a port they are assigned to the VLAN specified as the PVID or native VLAN. PVID is more applicable to access and general mode ports for configuration and native VLAN configuration applies to trunk mode settings. The default configuration for both PVID and native VLANs on the switch is 1, but this default setting can be modified for each specific environment.

With a tagged frame, the VLAN is identified by the VLAN ID in the tag and have this VLAN respectively set when traversing the switch. However, to reiterate, with an untagged frame, the VLAN identifier is the PVID specified for the port that received the frame (Dell.com, 2012).

Dell PowerConnect 8100 CLI

Run the commands below to configure Dell PowerConnect 8100 series switch for an untagged VLAN on port 1.

console#configure

console(config)#vlan 100

console(config-vlan)#exit

console(config)#interface te1/0/1

console(config-if-Te1/0/1)#switchport access vlan 100

console(config-if-Te1/0/1)#exit

11

Image 11
Contents Deploying Dell PowerConnect 8100 and Cisco Catalyst Switches Deploying the Dell PowerConnect 8100 with the Cisco Catalyst Contents Dell PowerConnect 8164F Dell PowerConnectManagement Vlan vs. SVI on the Cisco Catalyst Overview of VLANsCreating and assigning VLANs Dell PowerConnect 8100 CLI Management Vlan across a Dell PowerConnectCisco Catalyst CLI Cat6504E1#configure terminal Applying Vlan changes may take few minutes. Please wait Access, trunk and general Switchport ModesVlan configuration example Tagged Pvid and native Vlan Cat6504E1config-if#spanning-tree portfast edgeCisco Catalyst CLI Creating and connecting LAGs using Lacp Rstp Method 1 PortfastConsoleconfig#spanning-tree priority Method 2 Mstp Cisco proprietary protocolsDeploying the Dell PowerConnect 8100 with the Cisco Catalyst Appendix a Network switch versions