Dell 8100 manual Cisco Catalyst CLI, Cat6504E1#configure terminal

Page 7

Deploying the Dell PowerConnect 8100 with the Cisco Catalyst

Run the commands below on the Dell PowerConnect 8100 switch to create a management VLAN, which allows in-band management to the switch.

console#configure

console(config)#username admin1 password goodpa55 privilege 15 console(config)#vlan 50

console(config-vlan)#exitconsole(config)#interface vlan 50 console(config-if-vlan50)#ip address 5.5.5.5 /24 console(config-if-vlan50)#exitconsole(config)#interface tengigabitethernet 1/0/23 console(config-if-Te1/0/23)#switchport mode trunk console(config-if-Te1/0/23)#exitconsole(config)#interface tengigabitethernet 1/1/1 console(config-if-Te1/1/1)#switchport general allowed vlan add 50 console(config-if-Te1/1/1)#switchport general pvid 50 console(config-if-Te1/1/1)#switchport mode general

Running these commands opens a telnet session into the Dell PowerConnect 8100 switch through port 1/1/1 to management VLAN 50, using the username and password that were entered. In addition, port

1/0/23 is now ready to be connected to the Cisco Catalyst. Use the commands in the next section to configure the Cisco Catalyst switch.

While it may be tempting to add a “switchport trunk native vlan 50” line to the port 1/0/23 configuration, this command will block control traffic on a Cisco Catalyst 6500, although this command works between two 8100 switches, as well as between an 8100 and a Cisco Catalyst 3750. However, native VLANs work differently on the Cisco Catalyst 6500; it is recommended that the Native and SVI VLANs on the Cisco 6500 never be the same. If the port on the PowerConnect 8100 contains this line in the configuration, and a ping is not going through to the Cisco Catalyst 6500, set the option back to the default with the command: “switchport trunk native vlan 1”.

Cisco Catalyst CLI

Run the commands below on the Cisco Catalyst switch to create an SVI, which allows in-band management to the switch.

cat6504E_1#configure terminal

Enter configuration commands, one per line. End with CNTL/Z. cat6504E_1(config)#interface vlan 50 cat6504E_1(config-if)#ip address 5.5.5.7 255.255.255.0 cat6504E_1(config-if)#exit

cat6504E_1(config)#vlan 50

7

Image 7
Contents Deploying Dell PowerConnect 8100 and Cisco Catalyst Switches Deploying the Dell PowerConnect 8100 with the Cisco Catalyst Contents Dell PowerConnect 8164F Dell PowerConnectCreating and assigning VLANs Overview of VLANsManagement Vlan vs. SVI on the Cisco Catalyst Dell PowerConnect 8100 CLI Management Vlan across a Dell PowerConnectCisco Catalyst CLI Cat6504E1#configure terminalApplying Vlan changes may take few minutes. Please wait Access, trunk and general Switchport ModesVlan configuration example Tagged Pvid and native Vlan Cat6504E1config-if#spanning-tree portfast edgeCisco Catalyst CLI Creating and connecting LAGs using Lacp Rstp Method 1 PortfastConsoleconfig#spanning-tree priority Method 2 Mstp Cisco proprietary protocolsDeploying the Dell PowerConnect 8100 with the Cisco Catalyst Appendix a Network switch versions