Datalogic Scanning 1000I manual LED and Beeper Indicators, Green LED Indications

Page 10

Getting Started

LED and Beeper Indicators

The scanner’s beeper sounds and its green LED illuminates to indicate various functions or errors on the scanner. The tables below list these indications. One exception to the behaviors listed in the tables is that the scanner’s functions are programmable, and may or may not be turned on. For example, certain indications, such as the power-up beep can be disabled using programming barcode labels.

Green LED Indications

LED

INDICATION

 

COMMENT

INDICATION

 

 

 

 

 

 

 

 

 

 

 

 

Power-on

Bright green flash

 

Indicates the scanner has finished all its power up tests and is

indication

 

now ready for ooperation.

 

 

 

 

 

 

Good Read

Bright green flash

 

Indicates a barcode has been read and decoded.

Indication

 

 

 

 

 

 

 

 

Scanner Ready

Constant dim green

 

The scanner is ready for operation.

 

 

 

 

 

Constant green flash

 

The scanner is in Sleep Mode. To wake the scanner up, move

Sleep Mode

 

an object in front of its window or press the button atop the

(100mS on, 1900mS off)

 

 

 

unit.

 

 

 

 

 

 

 

Host Disable

Constant green flash at 1 Hz

 

The scanner is disabled due to receiving a disble command

(100mS on, 900mS off)

 

from the POS terminal.

 

 

 

 

 

 

Diagnostics

Varies (see "Error Codes" on

 

The LED can provide diagnostic feedback if the scanner dis-

page 1-5for more information)

 

covers a problem during SelfTest.

 

 

 

 

 

 

BEEPER FUNCTIONS

 

 

 

 

 

 

BEEPER

INDICATION

 

COMMENT

INDICATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The Power-On LED indication is a configurable feature which

Power On Beep

Single beep

 

can be enabled or disabled. When enabled, this beep Indi-

 

cates the scanner has finished all its power up tests and is

 

 

 

 

 

 

now ready for operation.

 

 

 

 

Good Read

 

 

The good read beep indication is configurable. Options

Single beep

 

include: Enable/disable, frequency, duration and volume. See

Indication

 

 

 

the Product Reference Guide (PRG) for more information.

 

 

 

 

 

 

 

Diagnostics

Varies (see "Error Codes" on

 

The Beeper can provide diagnostic feedback if the scanner

page 1-5for more information)

 

discovers a problem during SelfTest.

 

 

 

 

 

 

Programming

Varies (see the Product Reference

 

The Beeper will sound as programming barcode labels are

Mode

Guide for more information about

 

 

scanned, indicating progress during scanner configuration.

Indications

scanner programming)

 

 

 

 

 

 

 

1-4

Magellan® 1000i

Image 10
Contents MagellanTM Datalogic Scanning, Inc Table of Contents Magellan Iii Datamatrix Length 1, Length 2 Programming Instructions About This Manual Manual ConventionsConnecting the Scanner Cable To Host/Terminal Connect HereUsing the Programming Barcodes Resetting the Standard Product DefaultsProgramming LED and Beeper Indicators Green LED IndicationsError Codes ErrorMagellan General Features Double Read TimeoutDouble Read Timeout Label Gone Timeout Productivity Index Reporting PIRSleep Mode Sleep Mode Power On Alert Good Read When to Indicate Good Read Beep Control Good Read Beep FrequencyGood Read Beep Length Specifies the duration of a good read beepGood Read Beep Volume Target Mode Active Time Scanning FeaturesTargeted Scanning Mode Target Mode Linger Time Wake Up Intensity Wake Up Intensity Interface Related Features Keyboard Wedge Interface Reference Interface Selection Interface Selection Keyboard Wedge P Keyboard Wedge Q Interface Selection Interface Features Obey/Ignore Host CommandsInterface Features Host Transmission BuffersRS-232 Interface Features RS-232 Interface Features Hardware Flow Control Intercharacter Delay Intercharacter Delay Software Flow ControlHost Echo Host Echo Quiet Interval Signal Voltage Normal/TTL Host Echo Quiet IntervalRS-232 Invert Beep on Ascii BELBeep on Not on File ACK NAK Options ACK Character NAK CharacterRetry on ACK NAK Timeout ACK NAK Timeout ValueACK NAK Retry Count ACK NAK Error Handling Transmission Failure Indication USB-OEM Interface FeaturesUSB-OEM Device usage IBM IBM Transmit Labels in Code 39 FormatWand Emulation Supported SymbologiesWand Emulation Barcode Format Bar/Space Polarity Wand Idle StateSignal Speed Transmit Trailing NoiseSymbology Conversion Transmit Leading NoiseKeyboard Wedge USB Keyboard Keyboard Wedge Caps Lock State Disable Power-on Simulation Control Characters 010 100 msec USB COM Interface Set-up Data Editing Overview Please Keep In MindScan the END barcode to exit Programming Mode Global Prefix/SuffixGlobal Prefix/Suffix AIM ID Label ID Label ID Position OptionsLabel ID Default Setting for this Feature FF 4646 hex Default Setting for this Feature F 46 hex Default Setting for this Feature G8 4738 hex Magellan Default Setting for this Feature % 25 hex Case Conversion Character Conversion 41423132FFFFFFFFMagellan Symbologies Disable/Enable UPC-ACheck Digit Transmission UPC-AExpand UPC-A to EAN-13 Number System Transmission UPC-A Minimum ReadsUPC-A In-store Minimum Reads Disable/Enable UPC-E UPC-ENumber System Digit UPC-EExpand to UPC-E to UPC-A Expand UPC-E to EAN13 Minimum ReadsGtin Expand UPC/EAN to GtinDisable/Enable EAN-13 EAN-13EAN-13 EAN-13 Flag 1 CharacterMinimum Reads Disable/Enable EAN-8 EAN-8EAN-8 Enable EAN Two-Label Add-ons Add-ons GS1 DataBar Omnidirectional / Stacked Omnidirectional Disable/Enable GS1 DataBar OmnidirectionalUCC/EAN 128 Emulation GS1 DataBar Omnidirectional / Stacked Omnidirectional GS1 DataBar Expanded / Expanded Stacked Disable/Enable GS1 DataBar ExpandedGS1-128 Emulation GS1 DataBar Expanded / Expanded Stacked Length ControlSet Length Minimum Reads This feature controls coupon reading Coupon Read ControlDisable/Enable GS1 DataBar Limited GS1 DataBar LimitedGS1 DataBar Limited Code Disable/Enable CodeCheck Character Calculation Check Character Transmit Start/Stop CharactersCode 39 Full Ascii Code Code 39 Length 1, Length 2 Programming Instructions Quiet ZonesCode 39 Stitching Disable/Enable Pharmacode PharmacodePharmacode Disable/Enable EAN Transmit Function Characters Length Control Code 128 Length 1, Length 2 Programming Instructions Code 128 Conversion to CodeCode 128 Stitching Interleaved 2 Disable/Enable Interleaved 2Check Digit Calculation Interleaved 2 Check Digit TransmitLength Control Default Setting for this Feature Interleaved 2 of 5 Stitching Minimum Reads Codabar Disable/Enable CodabarCheck Character Verification Check Character Transmit Codabar Codabar Length 1, Length 2 Programming Instructions Quiet ZonesStart/Stop Character Type Start/Stop Character TransmissionStart/Stop Character Match Codabar StitchingMinimum Reads Following options apply to the Code 93 symbology Code Code 93 Length 1, Length 2 Programming Instructions Code 93 Stitching MSI/Plessey Disable/Enable MSI/PlesseyCheck Digit Verification MSI/Plessey Number of Check CharactersLength Control MSI/Plessey Length 1, Length 2 Programming Instructions MSI/Plessey Stitching Minimum Reads Disable/Enable Standard 2 Standard 2Standard 2 Length Control Standard 2 of 5 Length 1, Length 2 Programming Instructions Standard 2 of 5 Stitching Minimum Reads Magellan 2D Symbologies & Advanced Decoding Features 2D Symbologies Length Control Default Setting for this Feature 01 Minimum Reads Disable/Enable Datamatrix DatamatrixDatamatrix Datamatrix Length 1, Length 2 Programming Instructions Minimum Reads Image Capture How to Capture an ImageCaptured Image Format Scanner Dimensions Optical and Read Performance ParametersEnvironmental Parameters Physical PropertiesElectrical Parameters Other ParametersRS-232 Standard Cable Pinouts Primary Interface CablesIBM Port 5B/9B/17 USB, USB Keyboard & USB COM Keyboard WedgeAlpha-Numeric Pad Alpha-Numeric Pad Defaults by Symbology Appendix DInterface Default Exceptions IBM InterfacesInterface Default Exceptions RS-232 Wincor/NixdorfKeyboards Appendix E Keyboard Model Cross ReferenceTable E-2. Scanset 1 Function Key Map Table E-4.Scanset 3, 102-Key Function Key Map Table E-5. Scanset 3 122-Key Function Key Map Table E-6. Japanese DOS Function Key Map Table E-7. NEC 9801-Key Function Key Map Chapter F Host Commands Accepting RS-232 CommandsMagellan Chapter G Sample Symbols Sample Symbols Ascii Chart Datalogic Scanning, Inc
Related manuals
Manual 160 pages 40.26 Kb Manual 44 pages 55.92 Kb