Datalogic Scanning 1000I manual Table E-5. Scanset 3 122-Key Function Key Map

Page 168

Table E-5. Scanset 3 122-Key Function Key Map

ASCII (hex)

ASCII code

Key

Scancode

 

 

 

 

00

NUL

ALT Right Make

39h

01

SOH

ALT Right Break

F0h 39h

02

STX

ALT left Make

19h

03

ETX

ALT left Break

F0h 19h

04

EOT

CTRL left (RESET) Make only

11h

05

ENQ

CTRL left (RESET) Make/Break

11h F0h 11h

06

ACK

ONLINE Enter Make only

58h

07

BEL

ONLINE Enter Make/Break

58h F0h 58h

08

BS

BS

66h

09

HT

TAB right

0Dh

0A

LF

RIGHT arrow (inner keypad)

6Ah

0B

VT

TAB left

0Dh + S

0C

FF

CR (FIELD EXIT) Make only

5Ah F0h 5Ah

0D

CR

CR (FIELD EXIT) Make/Break

5Ah

0E

SO

INSERT (inner keypad)

65h

0F

SI

FIELD +

79h

10

DLE

FIELD -

7Ch

11

DC1

HOME (inner keypad)

62h

12

DC2

LEFT arrow (inner keypad)

61h

13

DC3

DOWN arrow (inner keypad)

60h

14

DC4

UP arrow (inner keypad)

63h

15

NAK

F6

2Fh

16

SYN

F1

07h

17

ETB

F2

0Fh

18

CAN

F3

17h

19

EM

F4

1Fh

1A

SUB

F5

27h

1B

ESC

ESC

08h

1C

FS

F7

37h

1D

GS

F8

3Fh

1E

RS

F9

47h

1F

US

F10

4Fh

E-4

Magellan® 1000i

Image 168
Contents MagellanTM Datalogic Scanning, Inc Table of Contents Magellan Iii Datamatrix Length 1, Length 2 Programming Instructions About This Manual Manual ConventionsConnecting the Scanner Cable To Host/Terminal Connect HereResetting the Standard Product Defaults Using the Programming BarcodesProgramming LED and Beeper Indicators Green LED IndicationsError Codes ErrorMagellan General Features Double Read TimeoutDouble Read Timeout Label Gone Timeout Productivity Index Reporting PIRSleep Mode Sleep Mode Power On Alert Good Read When to Indicate Good Read Beep Control Good Read Beep FrequencyGood Read Beep Length Specifies the duration of a good read beepGood Read Beep Volume Scanning Features Target Mode Active TimeTargeted Scanning Mode Target Mode Linger Time Wake Up Intensity Wake Up Intensity Interface Related Features Keyboard Wedge Interface Reference Interface Selection Interface Selection Keyboard Wedge P Keyboard Wedge Q Interface Selection Interface Features Obey/Ignore Host CommandsInterface Features Host Transmission BuffersRS-232 Interface Features RS-232 Interface Features Hardware Flow Control Intercharacter Delay Intercharacter Delay Software Flow ControlHost Echo Host Echo Quiet Interval Signal Voltage Normal/TTL Host Echo Quiet IntervalRS-232 Invert Beep on Ascii BELBeep on Not on File ACK NAK Options ACK Character NAK CharacterRetry on ACK NAK Timeout ACK NAK Timeout ValueACK NAK Retry Count ACK NAK Error Handling USB-OEM Interface Features Transmission Failure IndicationUSB-OEM Device usage IBM IBM Transmit Labels in Code 39 FormatSupported Symbologies Wand EmulationWand Emulation Barcode Format Bar/Space Polarity Wand Idle StateSignal Speed Transmit Trailing NoiseSymbology Conversion Transmit Leading NoiseKeyboard Wedge USB Keyboard Keyboard Wedge Caps Lock State Disable Power-on Simulation Control Characters 010 100 msec USB COM Interface Set-up Data Editing Overview Please Keep In MindScan the END barcode to exit Programming Mode Global Prefix/SuffixGlobal Prefix/Suffix AIM ID Label ID Label ID Position OptionsLabel ID Default Setting for this Feature FF 4646 hex Default Setting for this Feature F 46 hex Default Setting for this Feature G8 4738 hex Magellan Default Setting for this Feature % 25 hex Case Conversion Character Conversion 41423132FFFFFFFFMagellan Symbologies Disable/Enable UPC-AUPC-A Check Digit TransmissionExpand UPC-A to EAN-13 Number System Transmission UPC-A Minimum ReadsUPC-A In-store Minimum Reads Disable/Enable UPC-E UPC-EUPC-E Number System DigitExpand to UPC-E to UPC-A Expand UPC-E to EAN13 Minimum ReadsGtin Expand UPC/EAN to GtinDisable/Enable EAN-13 EAN-13EAN-13 EAN-13 Flag 1 CharacterMinimum Reads Disable/Enable EAN-8 EAN-8EAN-8 Enable EAN Two-Label Add-ons Add-ons Disable/Enable GS1 DataBar Omnidirectional GS1 DataBar Omnidirectional / Stacked OmnidirectionalUCC/EAN 128 Emulation GS1 DataBar Omnidirectional / Stacked Omnidirectional Disable/Enable GS1 DataBar Expanded GS1 DataBar Expanded / Expanded StackedGS1-128 Emulation GS1 DataBar Expanded / Expanded Stacked Length ControlSet Length Minimum Reads This feature controls coupon reading Coupon Read ControlDisable/Enable GS1 DataBar Limited GS1 DataBar LimitedGS1 DataBar Limited Disable/Enable Code CodeCheck Character Calculation Check Character Transmit Start/Stop CharactersCode 39 Full Ascii Code Code 39 Length 1, Length 2 Programming Instructions Quiet ZonesCode 39 Stitching Disable/Enable Pharmacode PharmacodePharmacode Disable/Enable EAN Transmit Function Characters Length Control Code 128 Length 1, Length 2 Programming Instructions Code 128 Conversion to CodeCode 128 Stitching Disable/Enable Interleaved 2 Interleaved 2Check Digit Calculation Interleaved 2 Check Digit TransmitLength Control Default Setting for this Feature Interleaved 2 of 5 Stitching Minimum Reads Disable/Enable Codabar CodabarCheck Character Verification Check Character Transmit Codabar Codabar Length 1, Length 2 Programming Instructions Quiet ZonesStart/Stop Character Type Start/Stop Character TransmissionStart/Stop Character Match Codabar StitchingMinimum Reads Following options apply to the Code 93 symbology Code Code 93 Length 1, Length 2 Programming Instructions Code 93 Stitching Disable/Enable MSI/Plessey MSI/PlesseyCheck Digit Verification MSI/Plessey Number of Check CharactersLength Control MSI/Plessey Length 1, Length 2 Programming Instructions MSI/Plessey Stitching Minimum Reads Disable/Enable Standard 2 Standard 2Standard 2 Length Control Standard 2 of 5 Length 1, Length 2 Programming Instructions Standard 2 of 5 Stitching Minimum Reads Magellan 2D Symbologies & Advanced Decoding Features 2D Symbologies Length Control Default Setting for this Feature 01 Minimum Reads Disable/Enable Datamatrix DatamatrixDatamatrix Datamatrix Length 1, Length 2 Programming Instructions Minimum Reads How to Capture an Image Image CaptureCaptured Image Format Scanner Dimensions Optical and Read Performance ParametersPhysical Properties Electrical ParametersEnvironmental Parameters Other ParametersStandard Cable Pinouts Primary Interface Cables RS-232IBM Port 5B/9B/17 USB, USB Keyboard & USB COM Keyboard WedgeAlpha-Numeric Pad Alpha-Numeric Pad Defaults by Symbology Appendix DInterface Default Exceptions IBM InterfacesInterface Default Exceptions RS-232 Wincor/NixdorfKeyboards Appendix E Keyboard Model Cross ReferenceTable E-2. Scanset 1 Function Key Map Table E-4.Scanset 3, 102-Key Function Key Map Table E-5. Scanset 3 122-Key Function Key Map Table E-6. Japanese DOS Function Key Map Table E-7. NEC 9801-Key Function Key Map Chapter F Host Commands Accepting RS-232 CommandsMagellan Chapter G Sample Symbols Sample Symbols Ascii Chart Datalogic Scanning, Inc
Related manuals
Manual 160 pages 40.26 Kb Manual 44 pages 55.92 Kb