Datalogic Scanning 1000I manual Keyboard Wedge Interface Reference

Page 28

Interface Related Features

Table 3-2. Keyboard Wedge Interface Reference

I/F Type

PCs Supported

 

 

A

PC/XT w/Alternate Key Encoding

B

AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key

Encoding

 

C

PS/2 25 and 30 w/Alternate Key Encoding

D

PC/XT w/Standard Key Encoding

E

AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key

Encoding

 

F

PS/2 25 and 30 w/Standard Key Encoding

G

IBM 3xxx w/122 keyboard

H

IBM 3xxx w/102 keyboard

I

PS/55 5530T w/104 keyboard

J

NEC 9801

K

WYSE 30/30+ WY-30 Keyboard 83 Keys

 

WYSE 60/85/99 GT/150/160/285 Style IBM Enhanced PC, 520/520ES

L

Style IBM Enhanced PC FR

 

WYSE 55/65/65 ES/120/185/325 Style IBM Enhanced PC

 

WYSE 60/85/99 GT/150/160/285 ANSI Keyboard 105 Keys, 520/520 ES

M

ANSI Keyboard 105 Keys

 

WYSE 55/65/65 ES/120/185/325 ANSI Keyboard 105 Keys

N

WYSE 60/85/99 GT/150/160/285 ASCII Kbd, 520/520 ES ASCII Kbd

WYSE 55/65/65 ES/120/185/325 ASCII Keyboard

 

 

WYSE 60/85/99 GT/150/160/285 ANSI W285 Keyboard 105 Keys, 520/

O

520 ES ANSI W285 Keyboard 105 Keys

 

WYSE 55/65/65 ES/120/185/325 ANSI W285 Keyboard 105 Keys

P

WYSE WINTERM 3320 SE

Q

IBM 3153

IBM 316X, 3179/3180/319X/3270

 

R

IBM 3151/3152-010, 347X/348X

S

DIGITAL VT 220/320/330/340/350/382

T

DIGITAL VT420

U

DIGITAL VT 510/520 IBM ANSI Style Keyboard

V

DIGITAL VT 510/520 IBM PC Style Keyboard

W

SUN SPARC 5/10

X

SUN 420/440, ITX

Y

WYSE 370/355 Style Enhanced IBM PC

Reference Appendix E, Keyboard Function Key Map- pings for more information about keyboards.

NOTE

3-2

Magellan® 1000i

Image 28
Contents MagellanTM Datalogic Scanning, Inc Table of Contents Magellan Iii Datamatrix Length 1, Length 2 Programming Instructions About This Manual Manual ConventionsConnecting the Scanner Cable To Host/Terminal Connect HereUsing the Programming Barcodes Resetting the Standard Product DefaultsProgramming LED and Beeper Indicators Green LED IndicationsError Codes ErrorMagellan General Features Double Read TimeoutDouble Read Timeout Label Gone Timeout Productivity Index Reporting PIRSleep Mode Sleep Mode Power On Alert Good Read When to Indicate Good Read Beep Control Good Read Beep FrequencyGood Read Beep Length Specifies the duration of a good read beepGood Read Beep Volume Target Mode Active Time Scanning FeaturesTargeted Scanning Mode Target Mode Linger Time Wake Up Intensity Wake Up Intensity Interface Related Features Keyboard Wedge Interface Reference Interface Selection Interface Selection Keyboard Wedge P Keyboard Wedge Q Interface Selection Interface Features Obey/Ignore Host CommandsInterface Features Host Transmission BuffersRS-232 Interface Features RS-232 Interface Features Hardware Flow Control Intercharacter Delay Intercharacter Delay Software Flow ControlHost Echo Host Echo Quiet Interval Signal Voltage Normal/TTL Host Echo Quiet IntervalRS-232 Invert Beep on Ascii BELBeep on Not on File ACK NAK Options ACK Character NAK CharacterRetry on ACK NAK Timeout ACK NAK Timeout ValueACK NAK Retry Count ACK NAK Error Handling Transmission Failure Indication USB-OEM Interface FeaturesUSB-OEM Device usage IBM IBM Transmit Labels in Code 39 FormatWand Emulation Supported SymbologiesWand Emulation Barcode Format Bar/Space Polarity Wand Idle StateSignal Speed Transmit Trailing NoiseSymbology Conversion Transmit Leading NoiseKeyboard Wedge USB Keyboard Keyboard Wedge Caps Lock State Disable Power-on Simulation Control Characters 010 100 msec USB COM Interface Set-up Data Editing Overview Please Keep In MindScan the END barcode to exit Programming Mode Global Prefix/SuffixGlobal Prefix/Suffix AIM ID Label ID Label ID Position OptionsLabel ID Default Setting for this Feature FF 4646 hex Default Setting for this Feature F 46 hex Default Setting for this Feature G8 4738 hex Magellan Default Setting for this Feature % 25 hex Case Conversion Character Conversion 41423132FFFFFFFFMagellan Symbologies Disable/Enable UPC-ACheck Digit Transmission UPC-AExpand UPC-A to EAN-13 Number System Transmission UPC-A Minimum ReadsUPC-A In-store Minimum Reads Disable/Enable UPC-E UPC-ENumber System Digit UPC-EExpand to UPC-E to UPC-A Expand UPC-E to EAN13 Minimum ReadsGtin Expand UPC/EAN to GtinDisable/Enable EAN-13 EAN-13EAN-13 EAN-13 Flag 1 CharacterMinimum Reads Disable/Enable EAN-8 EAN-8EAN-8 Enable EAN Two-Label Add-ons Add-ons GS1 DataBar Omnidirectional / Stacked Omnidirectional Disable/Enable GS1 DataBar OmnidirectionalUCC/EAN 128 Emulation GS1 DataBar Omnidirectional / Stacked Omnidirectional GS1 DataBar Expanded / Expanded Stacked Disable/Enable GS1 DataBar ExpandedGS1-128 Emulation GS1 DataBar Expanded / Expanded Stacked Length ControlSet Length Minimum Reads This feature controls coupon reading Coupon Read ControlDisable/Enable GS1 DataBar Limited GS1 DataBar LimitedGS1 DataBar Limited Code Disable/Enable CodeCheck Character Calculation Check Character Transmit Start/Stop CharactersCode 39 Full Ascii Code Code 39 Length 1, Length 2 Programming Instructions Quiet ZonesCode 39 Stitching Disable/Enable Pharmacode PharmacodePharmacode Disable/Enable EAN Transmit Function Characters Length Control Code 128 Length 1, Length 2 Programming Instructions Code 128 Conversion to CodeCode 128 Stitching Interleaved 2 Disable/Enable Interleaved 2Check Digit Calculation Interleaved 2 Check Digit TransmitLength Control Default Setting for this Feature Interleaved 2 of 5 Stitching Minimum Reads Codabar Disable/Enable CodabarCheck Character Verification Check Character Transmit Codabar Codabar Length 1, Length 2 Programming Instructions Quiet ZonesStart/Stop Character Type Start/Stop Character TransmissionStart/Stop Character Match Codabar StitchingMinimum Reads Following options apply to the Code 93 symbology Code Code 93 Length 1, Length 2 Programming Instructions Code 93 Stitching MSI/Plessey Disable/Enable MSI/PlesseyCheck Digit Verification MSI/Plessey Number of Check CharactersLength Control MSI/Plessey Length 1, Length 2 Programming Instructions MSI/Plessey Stitching Minimum Reads Disable/Enable Standard 2 Standard 2Standard 2 Length Control Standard 2 of 5 Length 1, Length 2 Programming Instructions Standard 2 of 5 Stitching Minimum Reads Magellan 2D Symbologies & Advanced Decoding Features 2D Symbologies Length Control Default Setting for this Feature 01 Minimum Reads Disable/Enable Datamatrix DatamatrixDatamatrix Datamatrix Length 1, Length 2 Programming Instructions Minimum Reads Image Capture How to Capture an ImageCaptured Image Format Scanner Dimensions Optical and Read Performance ParametersPhysical Properties Electrical ParametersEnvironmental Parameters Other ParametersRS-232 Standard Cable Pinouts Primary Interface CablesIBM Port 5B/9B/17 USB, USB Keyboard & USB COM Keyboard WedgeAlpha-Numeric Pad Alpha-Numeric Pad Defaults by Symbology Appendix DInterface Default Exceptions IBM InterfacesInterface Default Exceptions RS-232 Wincor/NixdorfKeyboards Appendix E Keyboard Model Cross ReferenceTable E-2. Scanset 1 Function Key Map Table E-4.Scanset 3, 102-Key Function Key Map Table E-5. Scanset 3 122-Key Function Key Map Table E-6. Japanese DOS Function Key Map Table E-7. NEC 9801-Key Function Key Map Chapter F Host Commands Accepting RS-232 CommandsMagellan Chapter G Sample Symbols Sample Symbols Ascii Chart Datalogic Scanning, Inc
Related manuals
Manual 160 pages 40.26 Kb Manual 44 pages 55.92 Kb