First Virtual Communications 3000 user manual VRA-3002T-XX-Y Scsi target interconnects

Page 14

Voyager 3000 User Guide

This system will typically be used in similar situations to that described within the VRA- 3001T-XX-Y section on page 1-2 but with larger capacity requirements.

The VRA-3002T-XX-Y is configured as two SCSI buses. The first SCSI channel is connected to the top three drives in the first shelf (left hand side) which are set up as SCSI Ids 0à2. The cable is then routed to the top four drives in the second shelf. These drives are set up as SCSI Ids 3à6. The second channel is connected to the bottom three drives in the first shelf which are configured as SCSI Ids 0à2 and looped to the second shelf to connect to the bottom three drives which are set up at SCSI Ids 3à5. Refer to Figure 1-4 for a schematic view of the interconnects. Each of the systems described are also available with differential host SCSI buses giving an overall host cable length of 25 metres.

Figure 1-4 VRA-3002T-XX-Y SCSI target interconnects

1-4

Image 14
Contents Voyager Revision A41 November-1997Contents EMU Features Figures 31 Mapping Logical Volume 0 Partition 1 to Channel 2 LUN Tables Scope Disclaimer Warranty FAXPage Voyager 3000 Family Voyager 3000 Tower configurations Model Number DescriptionVoyager 3000 Rackmountable configurations Model Number DescriptionFWD VRA-3001T-XX-YHost Connection Codes Internal bus configuration of VRA-3001T-XX-Y VRA-3002T-XX-YVRA-3002T-XX-Y Scsi target interconnects VRA-3001R-FW-Y example configuration VRA-3001R-XX-YVRA-3002R-FW-Y example configuration VRA-3002R-XX-YCooling System FeaturesDevice Carrier RAID ControllerPower Supplies Scsi ConnectorsRAID Basics RAID 1 / 0+1RAID 5 layout Required Number of Drives and Net CapacityRAID 3 layout Minimum drives necessary for a RAID setAir Flow Unpacking and Initial SetupAmbient Temperature Mechanical LoadingGrounding Electrical ConsiderationsCircuit Overloading Setting the target Scsi Ids on a VRA-3001 system Setting the host Scsi IdsSetting the target Scsi Ids Rear view of single tower showing host connections Setting the target Scsi Ids on a VRA-3002 system Setting the Target Bus Scsi IDsLocation of DPS1 on VRA-3002 second backplane Scsi ID Switch DPS1 Cabling and Termination Issues OffLength in Metres Transfer Speed ComponentsDevices Controller Power Option BoardSCA attachment Description Part Number11 RAID Controller 13 Installing SIMMs Advanced Cooling ModulesDrive Removal Component Insertion and removalDrive Insertion PSU Insertion and Removal Controller Insertion and RemovalIntroduction Environmental Monitoring Unit ConfigurationsEMU Features Dual shelf configuration System ConfigurationsSingle Shelf configuration Setting up the EMU Location of EMU within the shelfEMU Switch Settings ID settings for the EMUSW5 SW6 Power Sequencing SignalsAvailable EMU information Read Only Memory locations within the EMUInterpreting the EMU LED feedback Interpreting the EMU LED FeedbackDevices/events monitored by the EMU Connecting the EMU Connecting the EMUs togetherThis page is intentionally left blank Controller Configuration Controller DescriptionRS232 Terminal Settings Accessing the Voyager 3000 MenusConnecting a Monitor Emulating a MonitorWindows Program Manager Setting Windows Terminal Emulation Windows Terminal Preferences Screen Creating a logical volume Windows Terminal Communication Settings10 Initial Screen 12 Verifying Drive Configuration 14 Creating a logical drive 16 Selecting drives for inclusion in a RAID set Creating a Second Logical Volume 19 Progress of RAID set creationAdding a Global Spare 22 Viewing all Logical DrivesPartitioning a Logical Volume 24 Allocating Capacities to partitionsMapping Host LUNs 27 Mapping Host LUNs29 Selecting a Volume for LUN mapping De-assigning LUN Mapping Scan New Scsi DrivesView and Edit logical drives View and Edit Scsi DrivesView and Edit Scsi Channels Scsi ID37 View and edit Scsi target View and Edit Configuration Parameters 38 View and edit configuration parametersDown Loading New Firmware View and Edit Peripheral DevicesSystem Functions Quick Installation View System InformationRAID3 RAID5 Creating a New Logical DriveRAID0 NEW DRV Microp Viewing Disks Assigned to a Logical DriveDRV=5 Assigning a Spare Drive Mapping a Logical Drive to a Host Channel and LUNCHL Setting the Scsi ChannelsDeleting a Logical Drive SXF=10MChannel Terminator Setting CHL=0Data Cache Setting Scsi Reset at Power-Up SettingSequential Drive Spin-Up Setting Viewing Connected DrivesSerial Number Issuing a ResetAdding New Drives into Current List Download FirmwareVoyager 3000 User Guide Weight Scsi connectorsOperating Temperature RAID levelPower consumption