First Virtual Communications 3000 Adding New Drives into Current List, Issuing a Reset, Xxxxxxxx

Page 71

3Press t or s to scroll through the available SCSI drives.

Adding New Drives into Current List

1

Press ENT for two seconds for the Main

Menu.

2Press t or s to select Scan new SCSI Drive and press ENT.

3

Press t or s to select channel and press

ENT.

4

Press t or s to select the ID number and

press ENT

for two seconds.

 

5

Repeat step 2 to 5 for all the new drives to

be

included.

 

 

Issuing a Reset

 

1

Press ENT for two seconds for the Main

Menu.

2Press t or s to select Reset This Controller and press

ENT.

3Press ENT for two seconds to confirm reset.

Front Panel Operation

Scan new SCSI

Drive ..

Scan Channel=1

..

Scan Channel=1

ID=0 ?

Reset This

Controller ..

Confirm Reset

This controller?

Serial Number

1

Press ENT for two seconds for the Main

Menu.

2

Press t or s to select Serial Number and

press

ENT.

 

 

The serial number of the unit will be displayed on the LCD panel.

Download Firmware

1

Press ENT for two seconds for the Main

Menu.

2Press t or s to select Download Firmware and press ENT.

3

Press ENT for two seconds to confirm

download

firmware.

 

 

4The controller will display message and await a response from the host.

Serial Number:

XXXXXXXX

Download

Firmware

Confirm

Down load?

Download

in Progress..

5-7

Image 71
Contents Revision A41 November-1997 VoyagerContents EMU Features Figures 31 Mapping Logical Volume 0 Partition 1 to Channel 2 LUN Tables Scope Disclaimer FAX WarrantyPage Model Number Description Voyager 3000 Tower configurations Model Number DescriptionVoyager 3000 Rackmountable configurations Voyager 3000 FamilyFWD VRA-3001T-XX-YHost Connection Codes VRA-3002T-XX-Y Internal bus configuration of VRA-3001T-XX-YVRA-3002T-XX-Y Scsi target interconnects VRA-3001R-XX-Y VRA-3001R-FW-Y example configurationVRA-3002R-XX-Y VRA-3002R-FW-Y example configurationRAID Controller System FeaturesDevice Carrier CoolingScsi Connectors Power SuppliesRAID 1 / 0+1 RAID BasicsMinimum drives necessary for a RAID set Required Number of Drives and Net CapacityRAID 3 layout RAID 5 layoutMechanical Loading Unpacking and Initial SetupAmbient Temperature Air FlowGrounding Electrical ConsiderationsCircuit Overloading Setting the target Scsi Ids on a VRA-3001 system Setting the host Scsi IdsSetting the target Scsi Ids Rear view of single tower showing host connections Setting the Target Bus Scsi IDs Setting the target Scsi Ids on a VRA-3002 systemLocation of DPS1 on VRA-3002 second backplane Scsi ID Switch DPS1 Off Cabling and Termination IssuesLength in Metres Transfer Speed ComponentsDevices Description Part Number Power Option BoardSCA attachment Controller11 RAID Controller Advanced Cooling Modules 13 Installing SIMMsDrive Removal Component Insertion and removalDrive Insertion Controller Insertion and Removal PSU Insertion and RemovalIntroduction Environmental Monitoring Unit ConfigurationsEMU Features Dual shelf configuration System ConfigurationsSingle Shelf configuration Location of EMU within the shelf Setting up the EMUID settings for the EMU EMU Switch SettingsRead Only Memory locations within the EMU Power Sequencing SignalsAvailable EMU information SW5 SW6Interpreting the EMU LED feedback Interpreting the EMU LED FeedbackDevices/events monitored by the EMU Connecting the EMUs together Connecting the EMUThis page is intentionally left blank Controller Description Controller ConfigurationEmulating a Monitor Accessing the Voyager 3000 MenusConnecting a Monitor RS232 Terminal SettingsWindows Program Manager Setting Windows Terminal Emulation Windows Terminal Preferences Screen Windows Terminal Communication Settings Creating a logical volume10 Initial Screen 12 Verifying Drive Configuration 14 Creating a logical drive 16 Selecting drives for inclusion in a RAID set 19 Progress of RAID set creation Creating a Second Logical Volume22 Viewing all Logical Drives Adding a Global Spare24 Allocating Capacities to partitions Partitioning a Logical Volume27 Mapping Host LUNs Mapping Host LUNs29 Selecting a Volume for LUN mapping Scan New Scsi Drives De-assigning LUN MappingView and Edit Scsi Drives View and Edit logical drivesScsi ID View and Edit Scsi Channels37 View and edit Scsi target 38 View and edit configuration parameters View and Edit Configuration ParametersDown Loading New Firmware View and Edit Peripheral DevicesSystem Functions View System Information Quick InstallationRAID3 RAID5 Creating a New Logical DriveRAID0 NEW DRV Microp Viewing Disks Assigned to a Logical DriveDRV=5 Mapping a Logical Drive to a Host Channel and LUN Assigning a Spare DriveSXF=10M Setting the Scsi ChannelsDeleting a Logical Drive CHLCHL=0 Channel Terminator SettingViewing Connected Drives Scsi Reset at Power-Up SettingSequential Drive Spin-Up Setting Data Cache SettingDownload Firmware Issuing a ResetAdding New Drives into Current List Serial NumberVoyager 3000 User Guide RAID level Scsi connectorsOperating Temperature WeightPower consumption