| Environmental Monitoring Unit | |
Table | ||||
|
|
|
|
|
SW5 |
| SW6 | Action |
|
Off |
| Off | No delayed power sequencing |
|
On |
| Off | Power sequencing if only 1 PSU is available |
|
X |
| On | Delayed power sequencing |
|
X = Don’t Care |
|
|
|
SW7 enables SCSI Termination power for bus one and SW8 enables SCSI Termination power for bus two.
Available EMU information
More comprehensive information is provided to intelligent agents such as Eurologic’s Vision software. Configuration, warning and status Information is available from all EMU’s. The single EMU Storage System will provide the data shown in Table
Table 3-4 Read Only Memory locations within the EMU
Data Name | Number of Information Bytes |
EMU Part No. | 4 bytes |
EMU Firmware Rev | 2 bytes |
EMU Serial No. | 4 bytes |
EMU Power Cycle Count | 2 bytes |
Status Byte | 2 bytes |
EMU Available | 2 bytes |
EMU Attention | 2 bytes |
Local Temp | 2 bytes |
EMU Data | 8 bytes |
Fan Insertion Count | 2 bytes per Fan |
PSU Insertion Count | 2 bytes per PSU |
SCSI Device Insertion Count | 2 bytes per SCSI Devices |
Table | |
Data Name | Number of Information Bytes |
Master | 12 bytes |
Alarm Temperature | 2 bytes |
Critical Temperature | 2 bytes |
Action Byte | 2 bytes |
SCSI Device Status | 2 bytes |
Power Supply Control & Status | 2 bytes |
Fan Status | 2 bytes |