First Virtual Communications 3000 user manual Location of DPS1 on VRA-3002 second backplane

Page 26

Voyager 3000 User Guide

Figure 2-7 Location of DPS1 on VRA-3002 second backplane

Switch positions 1-4 are used to set the starting ID for the first device (bay 0) on the bus. Devices in bays 1,2 and 3 will automatically increment this ID by one in turn5. For example if the device in bay 0 is set to be at SCSI ID 3 then the device in bay 1 will automatically appear as ID 4, the device in bay 2 will appear as ID 5 and the device in bay 3 will appear as ID 6. Since the addresses of the devices in the first backplane is set to occupy SCSI Ids 0à2 for each bus, the default setting for the devices in the second backplane is set to be at a base address of 3. As there are four switches the switch positions are arranged to allow 16 possible Ids from 0 à 15.

Switch positions 5-8 are used to set the starting address of the fifth device on the bus (bay 4) and in a similar manner devices in bays 6,7 and 8 will also be automatically incremented. The default setting for the second bus is also to start at a base address of 3. Figure 2-8 shows how to set up the SCSI IDs using switch DPS1.

5If the starting address is at 15 then the subsequent Ids will roll over so that the second drive will take SCSI ID 0, the third drive ID 1 etc.

2-6

Image 26
Contents Voyager Revision A41 November-1997Contents EMU Features Figures 31 Mapping Logical Volume 0 Partition 1 to Channel 2 LUN Tables Scope Disclaimer Warranty FAXPage Voyager 3000 Family Voyager 3000 Tower configurations Model Number DescriptionVoyager 3000 Rackmountable configurations Model Number DescriptionFWD VRA-3001T-XX-YHost Connection Codes Internal bus configuration of VRA-3001T-XX-Y VRA-3002T-XX-YVRA-3002T-XX-Y Scsi target interconnects VRA-3001R-FW-Y example configuration VRA-3001R-XX-YVRA-3002R-FW-Y example configuration VRA-3002R-XX-YCooling System FeaturesDevice Carrier RAID ControllerPower Supplies Scsi ConnectorsRAID Basics RAID 1 / 0+1RAID 5 layout Required Number of Drives and Net CapacityRAID 3 layout Minimum drives necessary for a RAID setAir Flow Unpacking and Initial SetupAmbient Temperature Mechanical LoadingGrounding Electrical ConsiderationsCircuit Overloading Setting the target Scsi Ids on a VRA-3001 system Setting the host Scsi IdsSetting the target Scsi Ids Rear view of single tower showing host connections Setting the target Scsi Ids on a VRA-3002 system Setting the Target Bus Scsi IDsLocation of DPS1 on VRA-3002 second backplane Scsi ID Switch DPS1 Cabling and Termination Issues OffLength in Metres Transfer Speed ComponentsDevices Controller Power Option BoardSCA attachment Description Part Number11 RAID Controller 13 Installing SIMMs Advanced Cooling ModulesDrive Removal Component Insertion and removalDrive Insertion PSU Insertion and Removal Controller Insertion and RemovalIntroduction Environmental Monitoring Unit ConfigurationsEMU Features Dual shelf configuration System ConfigurationsSingle Shelf configuration Setting up the EMU Location of EMU within the shelfEMU Switch Settings ID settings for the EMUSW5 SW6 Power Sequencing SignalsAvailable EMU information Read Only Memory locations within the EMUInterpreting the EMU LED feedback Interpreting the EMU LED FeedbackDevices/events monitored by the EMU Connecting the EMU Connecting the EMUs togetherThis page is intentionally left blank Controller Configuration Controller DescriptionRS232 Terminal Settings Accessing the Voyager 3000 MenusConnecting a Monitor Emulating a MonitorWindows Program Manager Setting Windows Terminal Emulation Windows Terminal Preferences Screen Creating a logical volume Windows Terminal Communication Settings10 Initial Screen 12 Verifying Drive Configuration 14 Creating a logical drive 16 Selecting drives for inclusion in a RAID set Creating a Second Logical Volume 19 Progress of RAID set creationAdding a Global Spare 22 Viewing all Logical DrivesPartitioning a Logical Volume 24 Allocating Capacities to partitionsMapping Host LUNs 27 Mapping Host LUNs29 Selecting a Volume for LUN mapping De-assigning LUN Mapping Scan New Scsi DrivesView and Edit logical drives View and Edit Scsi DrivesView and Edit Scsi Channels Scsi ID37 View and edit Scsi target View and Edit Configuration Parameters 38 View and edit configuration parametersDown Loading New Firmware View and Edit Peripheral DevicesSystem Functions Quick Installation View System InformationRAID3 RAID5 Creating a New Logical DriveRAID0 NEW DRV Microp Viewing Disks Assigned to a Logical DriveDRV=5 Assigning a Spare Drive Mapping a Logical Drive to a Host Channel and LUNCHL Setting the Scsi ChannelsDeleting a Logical Drive SXF=10MChannel Terminator Setting CHL=0Data Cache Setting Scsi Reset at Power-Up SettingSequential Drive Spin-Up Setting Viewing Connected DrivesSerial Number Issuing a ResetAdding New Drives into Current List Download FirmwareVoyager 3000 User Guide Weight Scsi connectorsOperating Temperature RAID levelPower consumption