DIAGNOSTIC

6-5) Alarm Sounds continuously(related to the buzzer)

1) If “Ding-Dong” sounds continuously

Start

Freezer door MICOM No. 49, Fridge door MICOM No. 47 CF - door micom no.50

CR - door micom no.48

Regular voltages are 5V to Open : 0V to Close.

Yes

Is the door slightly open?

 

 

 

 

 

 

 

No

 

Remove causes after understanding

 

 

the conditions for interference by door

 

 

 

 

Is moisture penetrated

Yes

gasket, food etc.

 

 

 

 

 

 

into the door S/W?

 

 

 

 

NO

 

 

 

 

 

 

 

 

 

Exchange the door S/W.

 

 

 

 

 

 

Is the input voltage of main PCB

NO

 

 

 

 

 

 

 

changed at door-open, door-close?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

Troubleshoot the breaking of

 

 

 

 

wire and bad door S/W.

Is connector (CN30) inserted

 

NO

 

 

 

 

 

 

 

 

 

correctly?

 

 

 

 

 

 

Separate the door S/W and check if the measured value of unit is changed from 0 to depending to S/W ON/OFF.

 

 

 

 

 

 

 

YES

 

Troubleshoot if connector is not

 

 

 

 

inserted or poor contact.

Main PCB and door S/W are

 

NO

 

 

 

 

 

 

 

 

 

normal?

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

inserted or poor contact.

 

 

 

 

Exchange the door S/W.

Main PCB and door S/W are normal.

 

 

 

 

 

 

 

 

 

 

 

 

2) If “Beep” sounds continuously

Start

Did you select forced

Selected

 

operation and forced defrosting?

 

NO

NO

Does buzzer still sound after power-on again?

Release the forced operation and forced defrosting functions, or turn ON again after power OFF.

YES

Check if there is any part shorted out or

foreign matter in the test jumper part within the

main-PCB.

Main PCB is normal

64

Page 65
Image 65
Samsung RM255BABB Alarm Sounds continuouslyrelated to the buzzer, If Ding-Dong sounds continuously Start, Gasket, food etc