OPERATING INSTRUCTIONS & INSTALLATION

Error items of self-diagnostics

No

ITEM

TROUBLE

REMARK

1

I/M-SENSOR

Electric wire cut, short-circuit, contact failure, sensor housing missing, while in

case of displaying a temperature defect, it is only displayed when the sensor

 

 

detected temperature is not lower than 122

nor higher than -58

2

R-SENSOR

Electric wire cut, short-circuit, contact failure, sensor housing missing, while in

case of displaying a temperature defect, it is only displayed when the sensor

 

 

detected temperature is not lower than 122

nor higher than -58

3

DEFROSTING

Electric wire cut, short-circuit, contact failure, sensor housing missing, while in

SENSOR OF R

case of displaying a temperature defect, it is only displayed when the sensor

 

COMPARTMENT

detected temperature is not lower than 122

nor higher than -58

AN error is displayed when there is a contact failure on the feedback signal

4R-FAN ERROR line, a motor wire missing or a defect of the motor itself, when operating the

 

 

relevant fan motor.

5

I/M FUNCTION

An error is displayed when there is bad horizontality and bad ice tray more

than twice for each item of the ice maker kit.

ERROR

 

** Pertinent only to dispenser models (external attachment type).

 

 

 

 

 

6

-

 

 

 

 

7

R-DEFROSTING

Error occurs and is displayed when regarding the R compartment defrosting heater, there is an electric wire

cut, short-circuit, contact failure, sensor housing missing, or defective temperature fuse. A defect is

ERROR

 

displayed if defrosting is not finished after continuous heating for more than 70 min, for the R compartment.

 

 

 

 

 

8

CR SENSOR

Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case

of displaying a temperature defect, it is only displayed when sensor detection

 

 

temperature is not lower than 122 nor higher than -58 ￿

 

 

 

 

DEFROSTING

Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case

9SENSOR OF CR of displaying a temperature defect, it is only displayed when sensor detection

COMPARTMENT

temperature is not lower than 122 nor higher than -58 ￿

DEFROSTING

Electric wire cut, short-circuit, contact failure, missing of sensor housing , while in

10SENSOR OF CF case of display of defect by temperature, it is only displayed when sensor detection

 

COMPARTMENT

temperature is not lower than 122

or not higher than -58

 

11

CR-DEFROST

Error occurs and is displayed when regarding the CR compartment defrosting heater, there is an electric wire

cut, short-circuit, contact failure, sensor housing missing, or defective temperature fuse. A defect is displayed

ERROR

 

if defrosting is not finished after continuous heating for more than 70 min, for the CR compartment.

 

 

 

 

 

12

CF-DEFROST

Error occurs and is displayed when regarding the CF compartment defrosting heater, there is an electric wire

cut, short-circuit, contact failure, sensor housing missing, or defective temperature fuse. A defect is displayed

ERROR

 

if defrosting is not finished after continuous heating for more than 70 min, for the CF compartment.

 

 

 

 

 

13

WATER

An Error is displayed in case of water heater housing missing or

HEATER ERROR

electric wire cut.

 

 

 

 

 

 

 

 

14

EXT-SENSOR

Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case

of displaying a temperature defect, it is only displayed when sensor detection

 

 

temperature is not lower than 122

nor higher than -58

￿

 

 

 

15

F-SENSOR

Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case

of displaying a temperature defect, it is only displayed when sensor detection

 

 

temperature is not lower than 122

nor higher than -58

￿

29

Page 30
Image 30
Samsung RM255BASB, RM255BABB manual Defrosting, Sensor of R, Error, CR Sensor, Cr-Defrost, Cf-Defrost, Water, Ext-Sensor