DIAGNOSTIC

6-2) If the compressor doesn’t work normally

Start

 

Does 5 min pass after

NO

 

COMP. OFF?

 

YES

Recheck the comp after a

 

5 min.

See the TEST FUNCTION

 

 

 

Does compressor work

in the manual.

 

 

 

 

with

forced operation?

 

 

YES

 

Did buzzer sound on forced operation?

NO

(Check certainly after forced start.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

Voltage value of MICOM pin No.9

 

 

 

 

 

 

 

 

 

High?(5V)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Exchange MICOM and

 

 

 

 

 

 

 

YES

 

PCB.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

Is the voltage on

 

 

 

 

 

 

IC73

pin No. 16, 0.8V?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace IC73 Driver

 

 

 

 

 

 

 

YES

IC(TD62083AP).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Is the CN72

 

 

 

 

 

 

 

 

 

 

 

 

connector normal?

YES

Is refrigerator sensor

NO

 

 

 

normal?

 

 

 

YES

 

 

 

 

Open and repair

 

 

 

 

the connection.

Is the temperature

 

 

NO

sensor of main PCB

 

 

Normal?

 

 

 

 

 

 

 

 

 

 

 

YES

Troubleshoot the

 

 

sensor pant and

 

 

 

 

Open and repair

Exchange PCB.

the connection.

 

 

 

 

NO

YES

Is COMP assembly

normal?

NO

Check connector for

contact failure.

YES

Normal

Exchange and repair

COMP. Assembly.

61

Page 62
Image 62
Samsung RM255BASB, RM255BABB manual If the compressor doesn’t work normally, Check connector for Contact failure