Page 31
Image 31
Error occurs and is displayed when regarding the F compartment defrosting heater, there is a electric wire

OPERATING INSTRUCTIONS & INSTALLATION

No

ITEM

TROUBLE

REMARK

16

F-DEF-SENSOR

Electric wire cut, short-circuit, contact failure, sensor housing missing, while in case

of displaying a temperature defect, it is only displayed when sensor detection

 

 

temperature is not lower than 122 nor higher than -58

￿

 

 

Error is displayed in case there is a contact failure on the feedback signal line,

17F-FAN ERROR motor wire missing or defect of the motor itself, when operating the relevant

fan motor.

Error is displayed in case there is contact failure on the feedback signal line,

18C-FAN ERROR motor wire missing or defect of the motor itself when operating the relevant

 

 

 

fan motor.

19

CF-SENSOR

Electric wire cut, short-circuit, contact failure, sensor housing missing, while in

case of displaying a temperature defect, it is only displayed when sensor

 

 

 

detection temperature is not lower than 122 nor higher than -58

 

 

 

 

20

F-DEFROSTING

Error occurs and is displayed when regarding the F compartment defrosting heater, there is a electric wire

cut, short-circuit, contact failure, of sensor housing missing, or defective temperature fuse. A defect is

ERROR

 

displayed if defrosting is not finished after continuous heating for more than 80 min, for the F compartment.

 

 

 

 

 

 

 

21

CF-FAN ERROR

Error is displayed in case there is a contact failure on the feedback signal line,

motor wire missing or defect of the motor itself, when operating the relevant fan

 

 

 

motor.

 

 

 

 

22

CR-FAN ERROR

Error is displayed in case there is a contact failure on the feedback signal line,

motor wire missing or defect of the motor itself, when operating the relevant fan

 

 

 

motor.

 

 

 

 

23

-

 

 

 

 

 

24

ICE PIPE

Error is displayed in case of ice pipe heater housing missing or

HEATER ERROR

electric wire cut.

 

 

 

 

 

25

Uart

 

 

COMMUNICATI

Communication error with the electric power cord MODEM

 

ON ERROR

 

 

 

 

 

26

L

M COMMUNICATI

Whole letters of the LCD panel repeat ON/OFF and buzzer generates alarm sound

if communication between MICOM MAIN LOAD is not achieved due to an

ON ERROR

 

interruption of more than 10 seconds.

 

 

 

 

 

 

 

27

P

M COMMUNICATI

Whole letters of the LCD panel repeat ON/OFF and buzzer generates alarm sound

ON ERROR

if communication between MICOM MAIN PANEL is not achieved due to an

 

interruption of more than 10 seconds.

 

 

 

30

Page 31
Image 31
Samsung RM255BABB, RM255BASB manual Operating Instructions & Installation