DISASSEMBLY AND REASSEMBLY

Evaporator Fan Motor in Fresh Select Zone TM

2. Unscrew the lower part and the center of the duct-work.

The Evaporator Fan Motor in the Fresh Select Zone is located in the lower part of the cooling compartment. 1.Unscrew the fan-cover. (2 screws)

screws

2.Separate the insulation covering the fan by removing the sponge and tape.

3.Separate the housing terminal connected to the fan, and lift up the FAN.

UPPER DUCTWORK

1.First separate the two lamp- covers which are in the upper part.

3.Unscrew (2 screws) the upper part of the evaporator cover to take out the duct work by pulling.

4.Separate the sensor-cover in the lower part of duct work. And then separate the housing terminals(lamp & thermistor) and pull them out using both hands.

57

Page 58
Image 58
Samsung RM255BASB, RM255BABB manual Upper Ductwork