Samsung RM255BASB, RM255BABB Diagnostic, If Water Drawer doesnt work normally Preliminary Check

Models: RM255BABB RM255BASB

1 88
Download 88 pages 34.33 Kb
Page 72
Image 72
6-10) If Water Drawer doesn't work normally

DIAGNOSTIC

6-10) If Water Drawer doesn't work normally

Preliminary Check

1.Stop water supply before disassembling or assembling because water is directly supplied to the water valve.

2.Keep in mind to avoid shock hazard during disassembly because power is always present on one side of wire.

Check water coming out when pressing water lever at dispenser.

Measure both terminals of RY7C contact point after disconnecting CN72 and CN73 connectors.

Start

Does it work normally when

 

YES

 

 

 

 

selecting water?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

Normal Working Condition

 

 

 

 

 

 

 

 

Was dispenser water

 

YES

 

 

 

 

s/w pressed?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

Check the instrumental interference

 

 

 

 

of dispenser water s/w.

Does Main MICOM No. 13 maintain

 

NO

 

 

 

 

 

 

 

0V when pressing water s/w?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Check CN50 connector, wire

 

 

 

 

and failure of water s/w itself.

Does IC74 No. 16 maintain 0V

 

NO

 

 

 

 

 

 

 

 

when pressing water s/w?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

Main PCB failure: Replace it

 

 

 

 

(IC74 failure).

Is RY70 relay AC contact terminal

 

NO

 

 

 

 

 

 

 

 

0when pressing water s/w?

 

 

 

 

 

 

 

 

YES

Normal Main PCB

-Need to check other sections. Check the wire between WATER SOLENOID VALVE and MAIN PCB. Failure of WATER VALVE itself connector contact failure

Check for connecting pipe failure.

Main PCB failure: Replace it. (RY7D Relay Contact Terminal Short Failure)

74

71

Page 72
Image 72
Samsung RM255BASB, RM255BABB Diagnostic, If Water Drawer doesnt work normally Preliminary Check, when pressing water s/w?