3-16) Load Condition Display Function

OPERATING INSTRUCTIONS & INSTALLATION

3-16) Load Condition Display Function

1)If the freezing setting + the refrigeration setting keys are pressed simultaneously for about 6 seconds under normal operation condition, the freezer compartment and the refrigerator compartment temperature setting displays go on ALL ON/OFF for about 2 seconds with a 0.5 second interval.

2)I the freezing setting + the refrigeration setting keys are pressed simulyaneously then released, and the Fresh Zone setting key is pressed (to generate a ding-dong sound), the load status display mode is introduced.

3)Load status display mode tells what kind of load is output by the current MICOM signal. I tells only that a MICOM signal has been output but it does not confirm whether or not the load actually operates. So even if the display output shows that the load is operating , in reality the load might not operate due to load abnormality, bad relay on PCB etc. while as such this function may be used in A/S by application.

4)Load status display function is maintained for only 30 seconds after which it automatically returns to normal condition.

5)Relevant displays about load status is as follows.

LOAD MODE CHECKLIST

No

LOAD ITEM

LOAD STATUS

 

 

 

1

R-FAN HIGH

R-FAN High speed rotation operation display

 

 

 

2

R-FAN LOW

R-FAN Low speed rotation operation display of R-FAN

 

 

 

3

R-DEF-HEATER

Displays operation of the R compartment defrosting heater

 

 

 

4

START MODE

Operation stage display (not important)

 

 

 

5

OVERLOAD MODE

When ambient temperature is not higher than 93.2

 

 

 

6

LOW TEMP. MODE

When ambient temperature is not lower than 62.6

 

 

 

7

DISPLAY MODE

During display mode operation

 

 

 

8

COMP

COMP. operation display

 

 

 

9

F-FAN HIGH

F-FAN high speed rotation operation display

 

 

 

10

F-FAN LOW

F-FAN low speed rotation operation display

 

 

 

11

F-DEF-HEATER

Displays operation of the F compartment defrosting heate

 

 

 

12

C-FAN HIGH

C-FAN High speed rotation operation display

 

 

 

13

C-FAN LOW

C-FAN low speed rotation operation display

 

 

 

14

DISPENSER-HEATER

Dispenser heater operation display

 

 

 

15

R-VALVE

Is it lighted when the R-VALVE is OPEN

 

 

 

16

CR-FAN

CR-FAN operation display

 

 

 

17

CR-DEF-HEATER

Operation display of CR compartment defrosting heater

 

 

 

18

ICE-PIPE-HEATER

ICE-PIPE heater operation display

 

 

 

19

F-VALVE

IIs it lighted when the F-VALVE is OPEN

 

 

 

20

CF-FAN

CF-FAN operation display

 

 

 

21

CF-DEF-HEATER

Displays operation of the CF compartment defrosting heater

 

 

 

22

WATER-HEATER

Water heater operation display

 

 

 

-

ORDINARY CONDITION

When both no. 5 and 6 are lights-out (64.4 ~93.2 )

 

 

 

FREEZERFRIDGE