6-4) If there is a trouble with self-diagnosis(sensor failure)

DIAGNOSTIC

6-4) If there is a trouble with self-diagnosis(sensor failure)

-Error in sensor can be seen on the front display of refrigerator. If sensor failure is found when power is initially impressed to refrigerator, the product will not work, and display is repeatedly blinking in the trouble occurred sensor.

-Even if sensor has failure during the oeration refrigerator will not stop working but can’t run the normal cooling operation because of being operated in the Emergency Operation mode. Thus, be sure to follow instructions in the manual when you make self-diagnosis.

1)If the ambient temperature sensor has trouble

This model has an ambient temperature sensing operation in the panel PCB. The sensed information is communicated between main PCB and panel PCB. So you must review the causes of failure without disassembling the panel PCB. If it displays the sensor ERROR in the parts related to the ambient temperature sensor on the panel, it is understood that the communication with MAIN PCB is normal. In this case, check the sensor unit, missing wires and short & breaking or wires, etc.

Start

See “CircuitOperation” and “HowTo CheckTemperaturesensor” inthe manual.(Checkvoltageatbothsensor terminalsontheupperhingeconnectorof freezer,ormeasureresistanceafter disassemblingtheconnector.)

ComparetheambienttempwithtempTable whenusingthemeasurementmethod describedonHowToCheckTemp Sensing.

Is Main PCB connector(CN50)

inserted correctly?

YES

Is the ambient temperature

sensor normal?

YES

Is the sensor voltage measured at the upper hinge connector normal?

NO

NO

NO

Troubleshoot the connector’s contact

failure or missing

Replace temperature sensor.

Measure the sensor-connected No. 7

No.8, after

YES

disconnecting wires from the upper hinge connector.

No trouble with PCB and temperature sensor.

Recheck connector for contact failure.

Check the soldering on the main PCB for

shorts & breaks.

2)If the temperature sensor of Refrigerator has trouble (Apply to the other sensor checks.) Start

See Circuit Operation” and “How To Check Temperature Sensing” in the manual.

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿ ￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿

Is the unit of refrigerator

sensor normal?

YES

Is Main PCB connector

(CN30) inserted correctly?

YES

Is the insertion sequence

of connector(CN30) wire identical to the circuit diagram?

YES

NO

NO

NO

Exchange the temperature sensor.

Troubleshoot the connector’s

contact failure or missing

Correct the wrong configuration of connector wire-if it is not inserted or incorrectly inserted to coincid with the circuit diagram.

See Circuit Operation” and

Is the input of voltage to Main

NO

 

MICOM pin No. 57 normal?

 

“How To Check Temperature

 

 

 

 

 

 

Sensing” in the manual.

 

YES

 

 

 

No trouble with PCB and temperature sensor.

Recheck the connector for an error of contact.

Check the soldering on the main PCB for

shorts & breaks