B&B Electronics MESR9xx manual Reloading Factory Defaults

Page 24

3. Setup and Connections

Vlinx MESR9xx Modbus Gateway

Reloading Factory Defaults

To reload Factory Defaults, press and hold the Mode switch for more than 10 seconds. The LED indicators respond as follows:

1.The Ready LED blinks three times per second while the button is being pressed.

2.The Modbus gateway is in Factory Default Mode when:

On the MESR901: Port 1 LED and the Ready LED are both On.

On MESR902x models: Port 1 LED and the Port 2 LED are both On.

The Modbus gateway reloads all factory default configuration parameters.

3. The LEDs go back to their normal states when the device resumes normal operation.

Note: Factor default parameters are listed in Appendix A

Page 20

Manual Documentation Number MESR9xx-4508m

 

www.bb-elec.com/

 

www.bb-europe.com/

Image 24 Contents
Vlinx MESR9xx Modbus Gateways Vlinx MESR9xx Table of Contents Upgrading the Modbus Gateway Firmware Introduction About MESR9xx Modbus GatewaysMESR9xx Modbus Gateway Model Numbering Model Number Features List of MESR9xx Modbus Gateway ModelsMESR9xx Modbus Gateway Features MESR901-SCVlinx Manager Configuration Software Package Checklist MESR9xx Modbus Gateway HardwareMESR9xx Modbus Gateway Enclosures and Mounting LED Indicators E1/E2 Ethernet Link LEDReady LED Serial Port LEDsMode Switch Ethernet ConnectorFiberoptic Connectors Serial Port ConnectorsPower Connector Mounting HardwareHardware Vlinx MESR9xx Modbus Gateway Modbus Gateway Setup and Connections Connecting the Power SupplyConnecting MESR9xx Modbus Gateways to Modbus networks Connecting the MESR9x1-x Connecting the MESR9x2T-x Connecting the MESR9x2D-xConnecting MESR9xx Modbus Gateways to a Network MESR9xx Modbus Gateway Configuration ConnectionsNetwork Connection 10BaseT/100BaseTX Fiberoptic Connection To open Vlinx Manager Vlinx Manager Login Screen Using MESR9xx Modbus Gateways in Direct IP Mode MESR9xx Modbus Gateway Operational ConnectionsInitiating a Hardware Reset on the Modbus Gateway Direct IP ConnectionReloading Factory Defaults Character Timeout Configuration FilesDescription, Modbus Gateway Properties AttachedDefault Gateway Data/Parity/StopFirmware Version Hardware VersionID Routing IP AddressLink Status MAC AddressModbus Priority Modbus Serial RetriesModbus Message Timeout Modbus AsciiModbus Message Buffering Modbus RTU MessageNetwork Mode Modbus TCP MessageModel Network ProtocolsPassword Port# ID RemapSerial Interface Modes Modbus Gateway Name Gateway Serial Port NumberSubnet Mask TCP Transmission Control Protocol Firmware Upgrade Dialog Box Upgrading the Modbus Gateway FirmwareDownloading Firmware Files Uploading the Firmware to the Modbus GatewayWhen the upgrade process is complete, click Close Diagnostics Testing a Modbus Gateway ConnectionDiagnostics Vlinx MESR9xx Modbus Gateway From Serial Master to Modbus Gateway, Slave IDs Configurable Application ExamplesFrom Serial Masters To Ethernet Master, Slave IDs Fixed Keep Serial Master, Add Ethernet MastersModbus RTU, ASCII, and TCP Integration Time Critical Control, Direct and Remotely MonitoredModbus Help Modbus ASCII/RTU BasicsHints and Tips Appendices Appendix a Default Gateway Settings Setting Default Value Gateway NamePassword Password field is blank from factory EnabledAppendix B Product Specifications General Specifications Controls, Indicators and Connector Specifications SwitchesIndicators ConnectorsSerial Interface Specifications Network Specifications Appendix C Dimensional Diagrams Appendices Vlinx MESR9xx Modbus Gateway Appendices Vlinx MESR9xx Modbus Gateway Appendices Vlinx MESR9xx Modbus Gateway Appendix D Connector Pinouts MESR901-x Serial Port PinoutsDB-9M Pin Terminal MESR902D-x Serial Port Pinouts MESR902T-x Serial Port Pinouts Standard Ethernet Cable RJ-45 Pin-out RJ-45 PinGlossary Term DefinitionPDU