7. Application Examples

Vlinx MESR9xx Modbus Gateway

7. Application Examples

Modbus gateways can be used to integrate Modbus networks in a wide variety of settings. But as each setting has its own requirements, users may not understand how a gateway helps, or if it’s appropriate for their specific needs.

The following scenarios are examples only, and many others are possible. Contact B&B Electronics technical support for information on other applications.

From Serial Master to Modbus Gateway, Slave IDs Configurable

4. The original system consists of Gateways controlling serial slave devices:

Figure 23. Direct IP Connection

The MESR Modbus gateway module connects serial slaves, so Ethernet SCADA masters can control these. As slave IDs must be unique in a single system, these must be changed to have them function on one network:

Figure 24. SCADA to Slaves, IDs Configurable

Page 35

Manual Documentation Number MESR9xx-4508m

 

www.bb-elec.com/

 

www.bb-europe.com/

Image 39 Contents
Vlinx MESR9xx Modbus Gateways Vlinx MESR9xx Table of Contents Upgrading the Modbus Gateway Firmware About MESR9xx Modbus Gateways IntroductionMESR9xx Modbus Gateway Model Numbering List of MESR9xx Modbus Gateway Models Model Number FeaturesMESR901-SC MESR9xx Modbus Gateway FeaturesVlinx Manager Configuration Software Package Checklist MESR9xx Modbus Gateway HardwareMESR9xx Modbus Gateway Enclosures and Mounting Serial Port LEDs LED IndicatorsE1/E2 Ethernet Link LED Ready LEDEthernet Connector Mode SwitchSerial Port Connectors Fiberoptic ConnectorsMounting Hardware Power ConnectorHardware Vlinx MESR9xx Modbus Gateway Modbus Gateway Setup and Connections Connecting the Power SupplyConnecting MESR9xx Modbus Gateways to Modbus networks Connecting the MESR9x1-x Connecting the MESR9x2D-x Connecting the MESR9x2T-xFiberoptic Connection Connecting MESR9xx Modbus Gateways to a NetworkMESR9xx Modbus Gateway Configuration Connections Network Connection 10BaseT/100BaseTXTo open Vlinx Manager Vlinx Manager Login Screen MESR9xx Modbus Gateway Operational Connections Using MESR9xx Modbus Gateways in Direct IP ModeDirect IP Connection Initiating a Hardware Reset on the Modbus GatewayReloading Factory Defaults Attached Character TimeoutConfiguration Files Description, Modbus Gateway PropertiesData/Parity/Stop Default GatewayIP Address Firmware VersionHardware Version ID RoutingModbus Serial Retries Link StatusMAC Address Modbus PriorityModbus RTU Message Modbus Message TimeoutModbus Ascii Modbus Message BufferingNetwork Protocols Network ModeModbus TCP Message ModelPassword Port# ID RemapSerial Interface Modes Modbus Gateway Name Gateway Serial Port NumberSubnet Mask TCP Transmission Control Protocol Upgrading the Modbus Gateway Firmware Firmware Upgrade Dialog Box Uploading the Firmware to the Modbus Gateway Downloading Firmware FilesWhen the upgrade process is complete, click Close Testing a Modbus Gateway Connection DiagnosticsDiagnostics Vlinx MESR9xx Modbus Gateway Application Examples From Serial Master to Modbus Gateway, Slave IDs ConfigurableKeep Serial Master, Add Ethernet Masters From Serial Masters To Ethernet Master, Slave IDs FixedTime Critical Control, Direct and Remotely Monitored Modbus RTU, ASCII, and TCP IntegrationModbus ASCII/RTU Basics Modbus HelpHints and Tips Appendices Enabled Appendix a Default Gateway SettingsSetting Default Value Gateway Name Password Password field is blank from factoryAppendix B Product Specifications General Specifications Connectors Controls, Indicators and Connector SpecificationsSwitches IndicatorsSerial Interface Specifications Network Specifications Appendix C Dimensional Diagrams Appendices Vlinx MESR9xx Modbus Gateway Appendices Vlinx MESR9xx Modbus Gateway Appendices Vlinx MESR9xx Modbus Gateway Appendix D Connector Pinouts MESR901-x Serial Port PinoutsDB-9M Pin Terminal MESR902D-x Serial Port Pinouts MESR902T-x Serial Port Pinouts RJ-45 Pin Standard Ethernet Cable RJ-45 Pin-outTerm Definition GlossaryPDU