B&B Electronics MESR9xx manual General Specifications

Page 47

9. AppendicesVlinx MESR9xx Modbus Gateway

General Specifications

Hardware and

Device

MESR901-x, MESR902D-x or

included accessories

MESR902T-x Modbus gateway module

 

 

CD

CD with Vlinx Manager software for

 

Windows 2000, 2003 Server/XP/Vista x32

 

 

Optional Accessories

Cable

232NM9 Null Modem Crossover Cable for

DTE to DTE connection

 

 

 

Rail

ERS35 one-meter length of steel 35mm

 

DIN Rail

 

 

Configuration Options

 

Using Vlinx Manager via a serial

Via serial port

connection, (press Reset button to enter

 

 

Console Mode)

 

Via network

Using Vlinx Manager via a Ethernet

 

connection

 

 

 

 

Using a standard web browser such as

 

 

Internet Explorer 6.0/7.0 or Firefox 1.5/2.0

Software

Vlinx Manager for

Windows 2000, 2003 Server, XP, & Vista

Modbus gateway

x32

 

configuration

 

 

Environment

Operating

-34 to 74 °C (-29 to 165 °F)

Temperature

 

 

 

Storage Temperature

-40 to 85 °C (-40 to 185 °F)

 

 

 

 

Operating Humidity

10 to 90% non-condensing

 

 

 

Certifications

FCC

Part 15 Class A

 

 

 

 

CE

CISPR (EN55022) Class A

 

 

 

 

 

EN61000-6-1 Generic Standards for

 

 

Residential, Commercial & Light Industrial

 

 

EN61000-4-2 to 11 ESD, RFI, EFT,

 

 

Surge, and CI

Enclosure

Rating

IP30

 

 

 

 

Mounting

DIN rail mount (35 mm)

 

 

 

 

Dimensions, Medium

1.2 x 4.5 x 6.2 in (2.8 x 11.4 x 15.7 cm)

 

Case

 

 

 

Dimensions, Small

1.2 in x 3.3 x 4.7 in (3.1 x 8.4 x 11.9 cm)

 

Case

 

 

Power Supply

Voltage Requirements

10 to 48 VDC

(External Supply

 

 

Required)

Power Consumption

MESR90x – 4.0W (Max)

 

MESR92x – 6.0W (Max)

 

 

Page 43

Manual Documentation Number MESR9xx-4508m

 

www.bb-elec.com/

 

www.bb-europe.com/

Image 47 Contents
Vlinx MESR9xx Modbus Gateways Vlinx MESR9xx Table of Contents Upgrading the Modbus Gateway Firmware About MESR9xx Modbus Gateways IntroductionMESR9xx Modbus Gateway Model Numbering List of MESR9xx Modbus Gateway Models Model Number FeaturesMESR901-SC MESR9xx Modbus Gateway FeaturesVlinx Manager Configuration Software MESR9xx Modbus Gateway Enclosures and Mounting Package ChecklistMESR9xx Modbus Gateway Hardware Serial Port LEDs LED IndicatorsE1/E2 Ethernet Link LED Ready LEDEthernet Connector Mode SwitchSerial Port Connectors Fiberoptic ConnectorsMounting Hardware Power ConnectorHardware Vlinx MESR9xx Modbus Gateway Connecting MESR9xx Modbus Gateways to Modbus networks Modbus Gateway Setup and ConnectionsConnecting the Power Supply Connecting the MESR9x1-x Connecting the MESR9x2D-x Connecting the MESR9x2T-xFiberoptic Connection Connecting MESR9xx Modbus Gateways to a NetworkMESR9xx Modbus Gateway Configuration Connections Network Connection 10BaseT/100BaseTXTo open Vlinx Manager Vlinx Manager Login Screen MESR9xx Modbus Gateway Operational Connections Using MESR9xx Modbus Gateways in Direct IP ModeDirect IP Connection Initiating a Hardware Reset on the Modbus GatewayReloading Factory Defaults Attached Character TimeoutConfiguration Files Description, Modbus Gateway PropertiesData/Parity/Stop Default GatewayIP Address Firmware VersionHardware Version ID RoutingModbus Serial Retries Link StatusMAC Address Modbus PriorityModbus RTU Message Modbus Message TimeoutModbus Ascii Modbus Message BufferingNetwork Protocols Network ModeModbus TCP Message ModelSerial Interface Modes PasswordPort# ID Remap Subnet Mask Modbus Gateway NameGateway Serial Port Number TCP Transmission Control Protocol Upgrading the Modbus Gateway Firmware Firmware Upgrade Dialog BoxUploading the Firmware to the Modbus Gateway Downloading Firmware FilesWhen the upgrade process is complete, click Close Testing a Modbus Gateway Connection DiagnosticsDiagnostics Vlinx MESR9xx Modbus Gateway Application Examples From Serial Master to Modbus Gateway, Slave IDs ConfigurableKeep Serial Master, Add Ethernet Masters From Serial Masters To Ethernet Master, Slave IDs FixedTime Critical Control, Direct and Remotely Monitored Modbus RTU, ASCII, and TCP IntegrationModbus ASCII/RTU Basics Modbus Help Hints and Tips Appendices Enabled Appendix a Default Gateway SettingsSetting Default Value Gateway Name Password Password field is blank from factoryAppendix B Product Specifications General Specifications Connectors Controls, Indicators and Connector SpecificationsSwitches IndicatorsSerial Interface Specifications Network Specifications Appendix C Dimensional Diagrams Appendices Vlinx MESR9xx Modbus Gateway Appendices Vlinx MESR9xx Modbus Gateway Appendices Vlinx MESR9xx Modbus Gateway DB-9M Pin Appendix D Connector PinoutsMESR901-x Serial Port Pinouts Terminal MESR902D-x Serial Port Pinouts MESR902T-x Serial Port Pinouts RJ-45 Pin Standard Ethernet Cable RJ-45 Pin-outTerm Definition GlossaryPDU