B&B Electronics 2010 manual Switch Settings, Switches SW1-1 and SW1-2 Character Length

Page 6

Figure 3. Opening the Model 2010’s case with a small screwdriver

3.2 SWITCH SETTINGS

All possible settings for the Model 2010's configuration switches are presented in the following summary table and descriptions. If you have additional questions regarding configuration, contact B&B Technical Support at (815) 433-5100.

Switches SW1-1 and SW1-2: Character Length

Switches SW1-1 and SW1-2 are set in combination to determine the character length for asynchronous data.

SW 1-1

SW 1-2

 

Off

On

8 bit

On

On

9 bit

Off

Off

10 bit

On

Off

11 bit

4

2010AS3297 Manual

B&B Electronics -- PO Box 1040 -- Ottawa, IL 61350

PH (815) 433-5100 -- FAX (815) 434-7094

Image 6
Contents Asynchronous to Synchronous Converter Table of Contents Warranty Information ServiceRadio and TV Interference Features General InformationDescription Configuration Setting Internal SwitchesSwitch Settings Switches SW1-1 and SW1-2 Character LengthSwitch SW1-4 Not Used Installation Connecting the Asynchronous PortConnecting the Synchronous Port Appendix a Specifications Data Transmission Full or half duplex ConnectorsAppendix B Asynchronous Port Connections Configured AS DCE Appendix C Synchronous Port Connections Configured AS DTE Appendix D Block Diagram