Bay Technical Associates 304, 303 manual Trademarks, Statement of Conditions

Page 2

4401 Great America Parkway

8 Federal Street

Santa Clara, CA 95054

Billerica, MA 01821

 

 

© 1997 by Bay Networks, Inc. All rights reserved.

Trademarks

Bay Networks is a registered trademark of Bay Networks, Inc. BayStack and Bay Networks Press are trademarks of Bay Networks, Inc.

Other brand and product names are registered trademarks or trademarks of their respective holders.

Statement of Conditions

In the interest of improving internal design, operational function, and/or reliability, Bay Networks, Inc. reserves the right to make changes to the products described in this document without notice.

Bay Networks, Inc. does not assume any liability that may occur due to the use or application of the product(s) or circuit layout(s) described herein.

Portions of the code in this software product are Copyright © 1988, Regents of the University of California. All rights reserved. Redistribution and use in source and binary forms of such portions are permitted, provided that the above copyright notice and this paragraph are duplicated in all such forms and that any documentation, advertising materials, and other materials related to such distribution and use acknowledge that such portions of the software were developed by the University of California, Berkeley. The name of the University may not be used to endorse or promote products derived from such portions of the software without specific prior written permission.

SUCH PORTIONS OF THE SOFTWARE ARE PROVIDED “AS IS” AND WITHOUT ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.

In addition, the program and information contained herein are licensed only pursuant to a license agreement that contains restrictions on use and disclosure (that may incorporate by reference certain limitations and notices imposed by third parties).

RESTRICTED RIGHTS LEGEND: Use, duplication, or disclosure by the U.S. Government is subject to the restrictions set forth in subparagraph (c)(1) of the Commercial Computer Software—Restricted Rights clause of FAR52.227-19 or subparagraph (c)(1)(a) of the Rights in Technical Data and Computer Software clause of DFARS 52.227-7013, and any successor rules or regulations, whichever is applicable.

Federal Communications Commission (FCC) Statement

Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy. If it is not installed and used in accordance with the instruction manual, it may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to take whatever measures may be necessary to correct the interference at their own expense.

ii

893-01010-A

Image 2
Contents Using BayStack 303 Ethernet Switches Federal Communications Commission FCC Statement TrademarksStatement of Conditions EN 55 022 Declaration of Conformance 893-01010-A Contents Chapter Installing the BayStack Switches Appendix a Technical Specifications Viii Figures 893-01010-A Tables Xii Purpose AudienceSpecial Message Formats Two-tiered Procedure FormatConventions Use of Enter, Type, and PressBay Networks Customer Support How to Get HelpOrdering Bay Networks Publications Region Telephone number Fax numberTechnical Solutions Center Telephone number Fax number For More InformationSafety Alert Message Format Xviii Copyright Safety Alert Messages Used in This GuideClass a Product Accumulated Weight Shelf or Table Mount See Caution onStacking Units in a Rack Turning Off Power to the Unit See Warning onReset To Default Settings Command Removing the Top Cover Introduction to the BayStack 303 and 304 Ethernet Switches FeaturesUsing the BayStack 303 and 304 Ethernet Switches Physical Description Front PanelBayStack 303 switch front panel 10BASE-T Ports10/100BASE-TX Port RJ-45 connector pinoutPin MDI-X signal Console Port Connector MDA SlotLEDs DB-9 connector pin assignmentsPins Signal name Direction Front-panel LEDsPower Status Meaning Power Cord SpecificationsPower and Status LEDs International power cord specifications Country/Plug description Specifications Typical plugPage Chapter Installing the BayStack Switches Installation RequirementsInstallation Procedure Installing the BayStack Switches on a Flat SurfaceInstalling the BayStack Switch in a Rack Attach the power cord to the back of the switchInstalling a Metal Chassis in a Rack Positioning the chassis in the rackInstalling a Plastic Chassis in a Rack Installing metal chassis in rackInstalling the plastic chassis in the rack Completing Rack Mounting Installation Attaching Devices to the BayStack Switch Connecting 10BASE-T PortsConnecting the 10/100BASE-TX Port 100 Mb/s port connectionsAutonegotiation Connecting the 100BASE-FX Port Connecting to the Console PortUsing the BayStack 303 and 304 Ethernet Switches Power-up Self-Tests Connecting to the console portPower Up Self Test screen Factory default settings Initial Setup of a BayStack Ethernet SwitchUsing Factory Default Settings Parameter Default valueSelecting a Language Language selection menuInitial Switch Setup Main MenuType 2 to select 2---System Configuration from the Main Menu Type 1 in the command line Type 2 in the command line Customizing and Managing the BayStack Switches Using the Menus and ScreensMenu and screen hierarchy Language Selection MenuMenu and Screen Areas Menu and screen areasCentral Screen Area Switch Status AreaNavigation Commands and Command Line Area Menu and Screen Descriptions Language Selection Menu Main MenuSpanning Tree Information Switch InformationSystem Information Spanning Tree General Information Customizing and Managing the BayStack Switches Spanning Tree Port Information Port Statistics and Status InformationCustomizing and Managing the BayStack Switches System Configuration Switch Network Configuration Port Configuration Spanning Tree ConfigurationGeneral Configuration Snmp Configuration Reset to Default Using the BayStack SwitchReset System Exit TelnetBefore AfterBayStack 303 as a desktop switch Spanning Tree ProtocolManaging the BayStack Switches Network Management with SnmpMIB Network Management Using a Telnet Connection Network Management through a Serial I/O ConnectionUpgrading Switch Software Through Tftp Connection Type 3 to select Reset System from the Main MenuPress Return when the Power Up Self Test screen is displayed Type 1 to select Upgrade Switch Software Page Chapter Troubleshooting and Diagnostics BayStack 303 and 304 Switch-related IssuesAutonegotiation MDI and MDI-X Connections MDI-X to MDI cable connectionsInstallation-related Issues MDI-X to MDI-X cable connectionsAddresses CablingLink Status General Specifications Performance Specifications Safety Agency ApprovalsPhysical Specifications Hardware ArchitectureDeclaration of Conformity Page Appendix B Media Dependent Adapters MDAs Table B-1 100BASE-FX MDA LEDs Label Color State Meaning10/100BASE-TX MDA Installing an MDA Table B-2 100BASE-TX MDA LEDsFigure B-3. Installing an MDA Page Numbers Autonegotiation, 1-5, 2-11Index-2 Index-3 Index-4 Index-5

304, 303 specifications

Bay Technical Associates (BTA) has established itself as a leader in the field of technology, particularly with the introduction of their BTA 303 and 304 models. These devices are designed to meet the increasing demands of various industries, ranging from telecommunications to manufacturing, by offering cutting-edge features and robust performance.

The BTA 303 is a versatile system that integrates advanced processing capabilities with a user-friendly interface. It comes equipped with high-speed data processing units that enable rapid analysis and decision-making. One of the standout features of the 303 model is its modular design, allowing users to easily customize and expand the system based on their specific requirements. This flexibility makes it an ideal choice for businesses looking to scale their operations without the need for a complete systems overhaul.

On the other hand, the BTA 304 pushes the envelope with its enhanced connectivity options. It supports multiple communication protocols, including Ethernet, Wi-Fi, and Bluetooth, which ensures seamless integration with other devices and systems. This level of connectivity is crucial for industries that rely on real-time data exchange and remote monitoring. Furthermore, the 304 model is equipped with advanced security features that protect sensitive information, a critical aspect in today’s data-driven world.

Both the BTA 303 and 304 leverage state-of-the-art technologies to enhance performance. They are built on a robust architecture that allows for high levels of data throughput without compromising on reliability. Additionally, these systems incorporate machine learning algorithms that enable predictive analytics, helping businesses to foresee challenges and optimize their operations accordingly.

In terms of user experience, BTA has focused on developing intuitive software that simplifies system management. The graphical user interface (GUI) is designed to be accessible, enabling users at all skill levels to navigate and utilize the system effectively. Comprehensive customer support is also provided, ensuring that users can maximize the potential of their BTA systems.

In conclusion, the BTA 303 and 304 models from Bay Technical Associates are exemplary systems that combine advanced features, modern technologies, and user-centric design. Their modularity, connectivity, and analytical capabilities position them as essential tools across various industries, driving efficiency and innovation. With ongoing advancements in technology, BTA continues to evolve, ensuring that its offerings remain at the forefront of the market.