Chapter 1 Cisco AS5850 Product Overview
Table
Pin | Description |
|
|
1 | Breaker enable |
|
|
2 | 5.15 voltage sense to backplane |
|
|
3 | 5.15 current sense, between PEMFs |
|
|
4 | 5.15 voltage sense return, to backplane |
|
|
5 | ID_P |
|
|
6 | ID_0 |
|
|
7 | 5.15 volt return, main bus return from backplane |
|
|
8 | 5.15 volt return, main bus return from backplane |
|
|
9 | 5.15 volt return, main bus return from backplane |
|
|
10 | 1.60 volt main power to backplane (2 amps) |
|
|
11 | Mbus_B_H, DATA |
|
|
12 | Mbus_B_L, DATA |
|
|
13 | Return line from pin 1 |
|
|
14 | open |
|
|
15 | open |
|
|
16 | 48 volt monitor to mbus (not backplane) |
|
|
17 | 48 volt current monitor to mbus (not backplane) |
|
|
18 | 1.60 volt current monitor, internal to PEMF |
|
|
19 | 5.15 volt / 15 amp peak |
|
|
20 | 5.15 volt |
|
|
21 | 5.15 volt |
|
|
22 | 1.6 volt return (2 amp) |
|
|
23 | Mbus_A_H, DATA |
|
|
24 | Mbus_A_L, DATA |
|
|
•Voltage level and current monitoring
The
The
2 seconds. The
If a PEMF is not properly seated in the Cisco AS5850 backplane, an electronic circuit, or interlock, trips a breaker in the PEMF and terminates power to the output connectors. This same interlock provides reverse polarity protection when the system is powered off.
| Cisco AS5850 Universal Gateway Hardware Installation Guide |