Multitech MT5634ZBA-SERIES manual New Zealand Telecom Warning Notice, South African Statement

Page 34

Appendix C – Regulatory Compliance

New Zealand Telecom Warning Notice

1.The grant of a Telepermit for any item of terminal equipment indicates only that Telecom has accepted that the item complies with minimum conditions for connection to its network. It indicates no endorsement of the product by Telecom, nor does it provide any sort of warranty. Above all, it provides no assurance that any item will work correctly in all respects with another item of Telepermitted equipment of a different make or model, nor does it imply that any product is compatible with all of Telecom’s network services.

This equipment is not capable under all operating conditions of correct operation at the higher speed which it is designated. 33.6 kbps and 56 kbps connections are likely to be restricted to lower bit rates when connected to some PSTN implementations. Telecom will accept no responsibility should difficulties arise in such circumstances.

2.Immediately disconnect this equipment should it become physically damaged, and arrange for its disposal or repair.

3.This modem shall not be used in any manner, which could constitute a nuisance to other Telecom customers.

4.This device is equipped with pulse dialing, while the Telecom standard is DTMF tone dialing. There is no guarantee that Telecom lines will always continue to support pulse dialing.

Use of pulse dialing, when this equipment is connected to the same line as other equipment, may give rise to ‘bell tinkle’ or noise and may also cause a false answer condition. Should such problems occur, the user should not contact the Telecom Faults Service.

The preferred method of dialing is to use DTMF tones, as this is faster than pulse (decadic) dialing and is readily available on almost all New Zealand telephone exchanges.

5.Warning Notice: No ‘111’ or other calls can be made from this device during a mains power failure.

6.This equipment may not provide for the effective hand-over of a call to another device connected to the same line.

7.Some parameters required for compliance with Telecom’s Telepermit requirements are dependent on the equipment (PC) associated with this device. The associated equipment shall be set to operate within the following limits for compliance with Telecom’s Specifications:

For repeat calls to the same number:

There shall be no more than 10 call attempts to the same number within any 30-minute period for any single manual call initiation, and

The equipment shall go on-hook for a period of not less than 30 seconds between the end of one attempt and the beginning of the next attempt.

For automatic calls to different numbers:

The equipment shall be set to ensure that automatic calls to different numbers are spaced such that there is no less than 5 seconds between the end of one call attempt and the beginning of another.

For automatically answered incoming calls:

The equipment shall be set to ensure that calls are answered between 3 and 30 seconds of receipt of ringing.

8.For correct operation, total of the RN’s of all devices connected to a single line at any time should not exceed 5.

South African Statement

This modem must be used in conjunction with an approved surge protection device.

Multi-Tech Systems, Inc. MT5634ZBA-Series User Guide (S000286G)

34

Image 34
Contents MultiModem ZBA MultiModem ZBA MT5634ZBA-Series User Guide Table of Contents Table of Contents Features Table IntroductionFeatures Specific to Change the Internal Jumpers InstallationSafety Warnings Opening the ModemChanging the Voice Jumper Global Connections Connect the Modem to Your PCNon-Global Connection Power-On Test Connect the Two-Wire Leased Line Leased Line OnlyConnect the Modem to the AC Power Outlet Connect the Modem to Your PCInstall the Modem Driver Installing the Modem DriverUsing the Global Wizard to Configure Your Modem Using AT Commands to Configure Your ModemConfigure the modem for best performance Modem Serial Speed GuidelinesOperation About the Front PanelLeased-Line Operation SetupOperation Connecting to the Internet AT Commands, S- Registers, and Result Codes Setup Remote ConfigurationBasic Procedure Changing the Setup PasswordCallback Security Changing the Setup PasswordTurning Callback Security On and Off Calling Procedures Setting Callback Security Message ParityAssigning Callback Passwords and Phone Numbers Password-Only CallbackNumber-Entry Callback Extension-Entry CallbackCallback Security Commands Direct ConnectionCallback Assignments Form None of the Indicators Light TroubleshootingModem Does Not Respond to Commands Page Page Modem Doesn’t Work with Caller ID Data Is Being LostThere Are Garbage Characters on the Monitor Fax and Data Software Can’t Run at the Same TimeAppendix a Technical Specifications Fax Data RatesReceiver Sensitivity Identify the Modem Firmware Upgrade OverviewAppendix B Upgrading the Modem’s Firmware Identify the Current Firmware VersionUpgrade the Modem’s Firmware Download the Upgrade FileExtract the Upgrade Files Restore Your ParametersFCC Part 15 Regulation Appendix C Regulatory ComplianceFCC Part 68 Telecom Industry Canada EMC, Safety and R&TTE Directive ComplianceCanadian Limitations Notice International Modem RestrictionsNew Zealand Telecom Warning Notice South African StatementAppendix D Waste Electrical and Electronic Equipment Weee Waste Electrical and Electronic Equipment StatementAppendix E Installing a Modem under Linux SetupAppendix F Connecting to a Cisco Router Connecting to a Cisco Router Console PortRemote Configuration Console Port ConnectionsAppendix G Rohs HT/TS Substance Concentration Index Caller IDIndex

MT5634ZBA-GLOBAL, MT5634ZBA-V-V92, MT5634ZBA-SERIES, MT5634ZBA specifications

The Multitech MT5634ZBA series is a line of high-performance 56K modems that have been engineered for reliable data transmission over telephone lines. This series includes models such as the MT5634ZBA, MT5634ZBA-SERIES, MT5634ZBA-V-V92, and MT5634ZBA-GLOBAL, each catering to different communication needs while maintaining a commitment to quality and efficiency.

One of the standout features of the MT5634ZBA series is its support for the V.92 protocol. This technology significantly enhances the modem's performance by allowing faster upload speeds compared to its predecessors. With V.92, users can enjoy uploads at speeds up to 48Kbps, which is particularly beneficial for those who frequently send large files or engage in video conferencing. Furthermore, the V.92 protocol supports features like modem-on-hold, enabling users to receive incoming calls without disconnecting their internet session.

Another notable characteristic of the MT5634ZBA series is its globally compatible design. The MT5634ZBA-GLOBAL version has been adapted to work with various international telecommunications standards, making it an excellent choice for businesses and individuals who require a reliable connection across different countries. This international usability ensures that users can connect seamlessly, regardless of location.

The MT5634ZBA modems also feature advanced error correction and data compression technologies, such as MNP2-4 error control, and V.42 bis compression. These technologies work together to improve data integrity and enhance the overall throughput of the modem, resulting in a more efficient and reliable connection.

In terms of hardware, the MT5634ZBA series modems are built with robust components that ensure longevity and consistent performance. They are equipped with standard serial interface ports that allow easy integration with various devices, such as computers, point-of-sale systems, and other communication equipment.

In summary, the Multitech MT5634ZBA series represents a significant advancement in modem technology, combining speed, reliability, and global adaptability. With its support for V.92, comprehensive error correction, and high-level data handling capabilities, the MT5634ZBA series is an ideal choice for users seeking efficient and effective communication solutions, whether at home or in business environments.