Multitech MT5634ZBA-SERIES, MT5634ZBA-V-V92 manual Console Port Connections, Remote Configuration

Page 38

Appendix F – Connecting to a Cisco Router

Step 3: Console Port Final Setup

Send the following command string to the modem connected to the console port of the Cisco router:

AT%R1&W0

The %R1 command sets E0, Q1, &D0, &K0, $SB9600, and %S1, and the &W0 command stores the commands to memory. The %R1 command sets the following functions:

E0

Turns command echo off

Q1

Turns result codes off

&D0

Ignores DTR from the DTE

&K0

Selects no flow control

$SB9600

Sets the serial baud rate to 9600 bps.

%S1

Disables command mode at all serial speeds except 115200 bps.

The modem is now configured for use on the Cisco router console port. Note that command echo and result codes have been turned off. If it becomes necessary to send additional AT commands to the modem after it has been so configured, there will be little feedback from the modem that it has received and acted upon the command. Only commands such as ATI0 that request specific data from the modem will send any data to the DTE as an indication that the modem has accepted the command. Temporarily turning on command echo and result codes might ease reconfiguration of the modem. When the modem is connected to the console port, turn the modem off and then on again. This will set the serial baud rate to 9600 bps as the $SB9600 command is implemented.

Console Port Connections

To connect a personal computer to the console port, use the RJ-45-to-RJ-45 roll-over cable and either the RJ-45-to-DB- 25 female DTE adapter or the RJ-45-to-DB-9 female DTE adapter (labeled “TERMINAL”).

Cable Pin-outs and Cabling Guide

Console

 

 

 

 

Modem

(DTE)

Console port

Console cable

Adapter

Adapter

(DCE)

signal

RJ-45 pin

RJ-45 pin

DB-9 pin

DB-25 pin

signal

RTS

1

8

8

4

RTS

DTR

2

7

6

20

DTR

XMT

3

6

2

2

XMT

GND

4

5

5

7

GND

GND

5

4

5

7

GND

RCV

6

3

3

3

RCV

DSR

7

2

4

6

DSR

CTS

8

1

7

5

CTS

Remote Configuration

The configuration of the modem described in Step 3 contains the core settings that allow the modem to function properly on the console port of the Cisco router. Commands in this section may be done remotely by calling into the MT5634ZBA attached to the console port with another modem.

Note: Setting country/region configuration and turning on callback security cannot be done remotely. Nor can all commands be executed remotely if the remote modem is set for callback security; remote configuration of a modem so configured is not recommended.

Establish a data connection with a remote MT5634ZBA modem.

Send three remote configuration escape characters followed by AT and the setup password, and then press ENTER. Example: %%%ATMTSMODEM. You have four tries to enter the correct password before being disconnected. If the password is correct, the remote modem may respond with OK. Note: If the modem has previously been configured with command echo off and result codes off, it may be difficult to determine if the remote modem is responding to commands. The ATI command can be used for this purpose. Even with echo and result codes off, the modem will respond with the requested ID string if it is properly receiving the command.

You can now send AT commands to configure the remote modem.

When you have finished configuring the remote modem, save the new configuration by typing AT&W0<CR>, then type ATO<CR> to exit remote configuration. You can then break the connection in the normal way.

Note: This step is important to ensure that the connection is broken cleanly.

Multi-Tech Systems, Inc. MT5634ZBA-Series User Guide (S000286G)

38

Image 38
Contents MultiModem ZBA MultiModem ZBA MT5634ZBA-Series User Guide Table of Contents Table of Contents Features Table IntroductionFeatures Specific to Change the Internal Jumpers InstallationSafety Warnings Opening the ModemChanging the Voice Jumper Non-Global Connection Connect the Modem to Your PCGlobal Connections Power-On Test Connect the Two-Wire Leased Line Leased Line OnlyConnect the Modem to the AC Power Outlet Connect the Modem to Your PCInstall the Modem Driver Installing the Modem DriverUsing the Global Wizard to Configure Your Modem Using AT Commands to Configure Your ModemConfigure the modem for best performance Modem Serial Speed GuidelinesOperation About the Front PanelOperation SetupLeased-Line Operation Connecting to the Internet AT Commands, S- Registers, and Result Codes Setup Remote ConfigurationBasic Procedure Changing the Setup PasswordTurning Callback Security On and Off Changing the Setup PasswordCallback Security Calling Procedures Setting Callback Security Message ParityAssigning Callback Passwords and Phone Numbers Password-Only CallbackNumber-Entry Callback Extension-Entry CallbackCallback Security Commands Direct ConnectionCallback Assignments Form Modem Does Not Respond to Commands TroubleshootingNone of the Indicators Light Page Page Modem Doesn’t Work with Caller ID Data Is Being LostThere Are Garbage Characters on the Monitor Fax and Data Software Can’t Run at the Same TimeAppendix a Technical Specifications Fax Data RatesReceiver Sensitivity Identify the Modem Firmware Upgrade OverviewAppendix B Upgrading the Modem’s Firmware Identify the Current Firmware VersionUpgrade the Modem’s Firmware Download the Upgrade FileExtract the Upgrade Files Restore Your ParametersFCC Part 68 Telecom Appendix C Regulatory ComplianceFCC Part 15 Regulation Industry Canada EMC, Safety and R&TTE Directive ComplianceCanadian Limitations Notice International Modem RestrictionsNew Zealand Telecom Warning Notice South African StatementAppendix D Waste Electrical and Electronic Equipment Weee Waste Electrical and Electronic Equipment StatementAppendix E Installing a Modem under Linux SetupAppendix F Connecting to a Cisco Router Connecting to a Cisco Router Console PortRemote Configuration Console Port ConnectionsAppendix G Rohs HT/TS Substance Concentration Index Caller IDIndex

MT5634ZBA-GLOBAL, MT5634ZBA-V-V92, MT5634ZBA-SERIES, MT5634ZBA specifications

The Multitech MT5634ZBA series is a line of high-performance 56K modems that have been engineered for reliable data transmission over telephone lines. This series includes models such as the MT5634ZBA, MT5634ZBA-SERIES, MT5634ZBA-V-V92, and MT5634ZBA-GLOBAL, each catering to different communication needs while maintaining a commitment to quality and efficiency.

One of the standout features of the MT5634ZBA series is its support for the V.92 protocol. This technology significantly enhances the modem's performance by allowing faster upload speeds compared to its predecessors. With V.92, users can enjoy uploads at speeds up to 48Kbps, which is particularly beneficial for those who frequently send large files or engage in video conferencing. Furthermore, the V.92 protocol supports features like modem-on-hold, enabling users to receive incoming calls without disconnecting their internet session.

Another notable characteristic of the MT5634ZBA series is its globally compatible design. The MT5634ZBA-GLOBAL version has been adapted to work with various international telecommunications standards, making it an excellent choice for businesses and individuals who require a reliable connection across different countries. This international usability ensures that users can connect seamlessly, regardless of location.

The MT5634ZBA modems also feature advanced error correction and data compression technologies, such as MNP2-4 error control, and V.42 bis compression. These technologies work together to improve data integrity and enhance the overall throughput of the modem, resulting in a more efficient and reliable connection.

In terms of hardware, the MT5634ZBA series modems are built with robust components that ensure longevity and consistent performance. They are equipped with standard serial interface ports that allow easy integration with various devices, such as computers, point-of-sale systems, and other communication equipment.

In summary, the Multitech MT5634ZBA series represents a significant advancement in modem technology, combining speed, reliability, and global adaptability. With its support for V.92, comprehensive error correction, and high-level data handling capabilities, the MT5634ZBA series is an ideal choice for users seeking efficient and effective communication solutions, whether at home or in business environments.