Maxon Telecom MM-6864, MM-6854 manual MM6854/64 Dual Band GSM Data Modem

Page 18

MM6854/64 Dual Band GSM Data Modem

ME 820047

Issue 1.0

Page 10

03/00

Image 18
Contents MM-6854 / MM-6864 GSM Dual-Band Data Modem Page MM6854/64 Dual Band GSM Data Modem MM6854/64 Dual Band GSM Data Modem Table of Contents Debugging & Indicator Lights List of Figures MM6854/64 Dual Band GSM Data Modem Introduction Summary Specifications Basic SpecificationsMM6854/64 Dual Band GSM Data Modem System Applications ApplicationsGSM / GPS Application GSM / GPS ApplicationNetwork Connection OperationIntroduction Inserting the SIM cardSet up the appropriate software Turning on the modemV.24 Interface Confirming Operation MM6854/64 Dual Band GSM Data Modem AT Commands 1 +++CR Escape command Re-execute last commandATA Manually answer an incoming call ATD Dial a telephone numberAtdl ATE Command Echo ATH Hang upATIn Identification 11 ATS0=n Auto-answer mode ATQ Result code suppression12 ATS1? Number of rings 15 ATS4 Line Feed character 14 ATS3 Command line termination character13 ATS2- Escape character 16 ATS5 Backspace character20 ATS10 Wait time before disconnection 18 ATS7 Wait time for carrier19 ATS8 Wait time before dialling 21 ATS12 Escape code guard time25 AT&C Data carrier detect options ATX Defines Connect results code formatATZ Load user profile 26 AT&D Data Terminal Ready options27 AT&F Restore default configuration 28 AT&V Display current configuration29 AT&W Save current configuration 30 AT+CBSTs,m,p Select bearer service type 31 AT+CEER Displays why last call was disconnected32 AT+CMGD Delete messages 33 AT+CMGF Message format 34 AT+CMGL List messages35 AT+CMGR Read messages 36 AT+CMGS Send messages37 AT+CMGW Write messages to memory 38 AT+CMSS Send messages from storage39 AT+CNMI New Message AT+CNMI=?40 AT+CPIN Enter PIN and query blocks 41 AT+CR Cellar result code for outgoing calls42 AT+CRC Cellar result code 44 AT+CSCA Service centre address 45 AT+CSDH Show test mode parameters43 AT+CRLP Radio Link Protocol parameters 46 AT+CSMP Set text mode parameters 47 AT+DR Data compression report48 AT+DS Data compression mode 49 AT+FCLASS Select, read or test service class50 AT+FMI Report manufacturer ID 53 AT+FRH Receive Hdlc data with carrier 51 AT+FMM Report module ID52 AT+FMR Report revision 54 AT + FRM Receive data with carrier57 AT+GMI Request manufacturer ID 55 AT+FTH Transmit Hdlc data with carrier56 AT+FTM Transmit data with carrier 58 AT+GMM Request model ID59 AT+GMR Request revision ID 60 AT+ICF Character framing61 AT+IFC Local flow control 62 AT+ILRR Display local report rate63 AT+IPR Set terminal equipment data rate CME ERRORn CMS ERRORnRegister Summary S0 Rings to auto-answerSummary MM6854/64 Dual Band GSM Data Modem Debugging & Indicator Lights MM6854/64 Dual Band GSM Data Modem Fusing InstallationPower Sources AntennasCabling FixingConnections 1 9 pin D-type RS-232 Interface2 25 pin D-type MM6854/64 Dual Band GSM Data Modem Setting up Windows Modem interface AppendicesOpen up the Control Panel Double click on the modem icon MM6854/64 Dual Band GSM Data Modem Select the appropriate COM port Set the location information Finish Installation Select Properties Select Connection Set Data Bits, Parity and Stop bits Select Flow Control and Software XON/XOFF 12 RS-232 Setting up Hyper Terminal Select Hyper Terminal from Programs MenuSelect Hyper Terminal Set Port Port Settings Ascii settings PropertiesSetting up Win Fax Pro Communication SetupWin Fax Pro Setup MM6854/64 Dual Band GSM Data Modem Accessories Description of Accessory Maxon Part NumberMM6854/64 Dual Band GSM Data Modem Glossary Abbreviation Meaning

MM-6854, MM-6864 specifications

Maxon Telecom is renowned for its innovative communication solutions, and two of its standout products are the MM-6864 and MM-6854 models. Both devices are designed to cater to the needs of modern enterprises, offering robust features and cutting-edge technology to enhance communication effectiveness.

The Maxon Telecom MM-6864 is a feature-rich communication device that emphasizes versatility and connectivity. One of its main features is its ability to support multiple communication protocols, making it compatible with a wide range of network systems. This flexibility is essential for businesses that require seamless integration with existing infrastructures. The MM-6864 also boasts advanced encryption technology, ensuring secure communications to protect sensitive information.

Another characteristic that sets the MM-6864 apart is its expansive coverage capabilities. The device utilizes the latest in antenna technology, which not only extends its range but also improves signal strength in challenging environments. This makes it an ideal choice for enterprises operating in remote locations or large facilities where maintaining a reliable connection is paramount.

On the other hand, the Maxon Telecom MM-6854 is tailored more towards compactness and user-friendliness without compromising on features. One of its significant characteristics is its lightweight design, making it easy to carry and suitable for on-the-go professionals. The MM-6854 also offers impressive battery life, allowing users to stay connected throughout their busy day without the constant need for recharging.

Both devices incorporate advanced digital signal processing (DSP) technology, ensuring clear audio quality during communications. This is crucial in fast-paced business environments where understanding every detail is vital. Additionally, they come equipped with customizable user interfaces, enabling users to tailor settings according to their specific needs, whether they are on a conference call or conducting day-to-day operations.

In conclusion, the Maxon Telecom MM-6864 and MM-6854 models stand out in the telecommunications landscape due to their combination of advanced features, reliable connectivity, and user-centric designs. Whether a business requires the extensive capabilities of the MM-6864 or the portability of the MM-6854, Maxon Telecom delivers devices that meet diverse communication needs while ensuring security and efficiency.