5.1.40 AT+CPIN – Enter PIN and query blocks

This command is used to validate the PIN code, or to validate the PUK code.

Enter

Response

AT+CPIN?

Displays the current status of the PIN code.

AT+CPIN=<puk>,<new_pin>

If PUK code is required. New_pin will be the new pin code for

 

the SIM card.

AT+CPIN=<pin>

Enter the PIN code for the SIM card.

 

Notes:

 

Result codes:

 

OK

 

ERROR

 

+CPIN READY

 

+CPIN SIM PIN “Pin code required”

 

+CPIN SIM PUK “PUK code required”

 

+CPIN SIM PIN2 “Pin 2 code required”

 

Mobile equipment result code

5.1.41 AT+CR – Cellar result code for outgoing calls

AT+CR=?

5.1.42 AT+CRC – Cellar result code

This command controls whether or not the extended format of incoming call indication is used. When enabled the modem will then send an extended string instead of the usual RING.

AT+CRC can have the value 0 or 1. If set to 0 the cellar result code will be disabled, and 1 will enable the result code.

Enter

Response

 

AT+CRC=?

Displays the mode selected:

 

+CRING:ASYNC

For asynchronous transparent

 

+CRING:REL ASYNC

For asynchronous non-transparent

 

+CRING:SYNC

For synchronous transparent

 

+CRING:REL SYNC

For synchronous non-transparent

 

+CRING:VOICE

For normal speech

 

+CRING:FAX

For fax calls

 

Notes:

 

 

Result codes:

 

 

OK

 

 

ERROR

 

Issue 1.0

ME 820047

03/00

Page 25

Image 33
Contents MM-6854 / MM-6864 GSM Dual-Band Data Modem Page MM6854/64 Dual Band GSM Data Modem MM6854/64 Dual Band GSM Data Modem Table of Contents Debugging & Indicator Lights List of Figures MM6854/64 Dual Band GSM Data Modem Introduction Summary Basic Specifications SpecificationsMM6854/64 Dual Band GSM Data Modem Applications System ApplicationsGSM / GPS Application GSM / GPS ApplicationIntroduction OperationNetwork Connection Inserting the SIM cardSet up the appropriate software Turning on the modemV.24 Interface Confirming Operation MM6854/64 Dual Band GSM Data Modem AT Commands Re-execute last command 1 +++CR Escape commandATA Manually answer an incoming call ATD Dial a telephone numberAtdl ATE Command Echo ATH Hang upATIn Identification 11 ATS0=n Auto-answer mode ATQ Result code suppression12 ATS1? Number of rings 13 ATS2- Escape character 14 ATS3 Command line termination character15 ATS4 Line Feed character 16 ATS5 Backspace character19 ATS8 Wait time before dialling 18 ATS7 Wait time for carrier20 ATS10 Wait time before disconnection 21 ATS12 Escape code guard timeATZ Load user profile ATX Defines Connect results code format25 AT&C Data carrier detect options 26 AT&D Data Terminal Ready options27 AT&F Restore default configuration 28 AT&V Display current configuration29 AT&W Save current configuration 30 AT+CBSTs,m,p Select bearer service type 31 AT+CEER Displays why last call was disconnected32 AT+CMGD Delete messages 34 AT+CMGL List messages 33 AT+CMGF Message format36 AT+CMGS Send messages 35 AT+CMGR Read messages38 AT+CMSS Send messages from storage 37 AT+CMGW Write messages to memoryAT+CNMI=? 39 AT+CNMI New Message40 AT+CPIN Enter PIN and query blocks 41 AT+CR Cellar result code for outgoing calls42 AT+CRC Cellar result code 44 AT+CSCA Service centre address 45 AT+CSDH Show test mode parameters43 AT+CRLP Radio Link Protocol parameters 47 AT+DR Data compression report 46 AT+CSMP Set text mode parameters48 AT+DS Data compression mode 49 AT+FCLASS Select, read or test service class50 AT+FMI Report manufacturer ID 52 AT+FMR Report revision 51 AT+FMM Report module ID53 AT+FRH Receive Hdlc data with carrier 54 AT + FRM Receive data with carrier56 AT+FTM Transmit data with carrier 55 AT+FTH Transmit Hdlc data with carrier57 AT+GMI Request manufacturer ID 58 AT+GMM Request model ID60 AT+ICF Character framing 59 AT+GMR Request revision ID61 AT+IFC Local flow control 62 AT+ILRR Display local report rate63 AT+IPR Set terminal equipment data rate CMS ERRORn CME ERRORnS0 Rings to auto-answer Register SummarySummary MM6854/64 Dual Band GSM Data Modem Debugging & Indicator Lights MM6854/64 Dual Band GSM Data Modem Power Sources InstallationFusing AntennasFixing CablingConnections 1 9 pin D-type RS-232 Interface2 25 pin D-type MM6854/64 Dual Band GSM Data Modem Setting up Windows Modem interface AppendicesOpen up the Control Panel Double click on the modem icon MM6854/64 Dual Band GSM Data Modem Select the appropriate COM port Set the location information Finish Installation Select Properties Select Connection Set Data Bits, Parity and Stop bits Select Flow Control and Software XON/XOFF 12 RS-232 Select Hyper Terminal from Programs Menu Setting up Hyper TerminalSelect Hyper Terminal Set Port Port Settings Properties Ascii settingsSetting up Win Fax Pro Communication SetupWin Fax Pro Setup MM6854/64 Dual Band GSM Data Modem Description of Accessory Maxon Part Number AccessoriesMM6854/64 Dual Band GSM Data Modem Abbreviation Meaning Glossary

MM-6854, MM-6864 specifications

Maxon Telecom is renowned for its innovative communication solutions, and two of its standout products are the MM-6864 and MM-6854 models. Both devices are designed to cater to the needs of modern enterprises, offering robust features and cutting-edge technology to enhance communication effectiveness.

The Maxon Telecom MM-6864 is a feature-rich communication device that emphasizes versatility and connectivity. One of its main features is its ability to support multiple communication protocols, making it compatible with a wide range of network systems. This flexibility is essential for businesses that require seamless integration with existing infrastructures. The MM-6864 also boasts advanced encryption technology, ensuring secure communications to protect sensitive information.

Another characteristic that sets the MM-6864 apart is its expansive coverage capabilities. The device utilizes the latest in antenna technology, which not only extends its range but also improves signal strength in challenging environments. This makes it an ideal choice for enterprises operating in remote locations or large facilities where maintaining a reliable connection is paramount.

On the other hand, the Maxon Telecom MM-6854 is tailored more towards compactness and user-friendliness without compromising on features. One of its significant characteristics is its lightweight design, making it easy to carry and suitable for on-the-go professionals. The MM-6854 also offers impressive battery life, allowing users to stay connected throughout their busy day without the constant need for recharging.

Both devices incorporate advanced digital signal processing (DSP) technology, ensuring clear audio quality during communications. This is crucial in fast-paced business environments where understanding every detail is vital. Additionally, they come equipped with customizable user interfaces, enabling users to tailor settings according to their specific needs, whether they are on a conference call or conducting day-to-day operations.

In conclusion, the Maxon Telecom MM-6864 and MM-6854 models stand out in the telecommunications landscape due to their combination of advanced features, reliable connectivity, and user-centric designs. Whether a business requires the extensive capabilities of the MM-6864 or the portability of the MM-6854, Maxon Telecom delivers devices that meet diverse communication needs while ensuring security and efficiency.