MP215 Mobile Modem | Installation, Configuration, and User’s Guide |
Syntax:AT+WS250=<autocheck>
Mode:AUTO
Default: | 300 seconds (5 min) |
Max value: 3600 seconds (1 hour)
Maxcdpdscan Timer
The Maxcdpdscan Timer defines how long to allow the modem to search for CDPD channels during an AUTO mode check. If CDPD service is not found within this time interval, the driver switches back to CS CDPD mode.
Syntax: | AT+WS251=<maxcdpdscan> |
Mode: | AUTO |
Default: | 90 seconds |
Max value: | 600 seconds (10 minutes) |
Maxcdpdlost Timer
The Maxcdpdlost Timer defines the tolerance to temporary losses of CDPD coverage. If CDPD service is lost continuously for this amount of time, the driver automatically switches to CS CDPD mode.
Syntax: | AT+WS252=<maxcdpdlost> |
Mode: | AUTO |
Default: | 90 seconds |
Max value: | 3600 seconds (1 hour) |
CDPDPresence Timer
The CDPDPresence timer defines the period for which CDPD must be present to prevent a switch from CDPD to
Syntax: | AT+WS254=<cdpdPresence> |
Mode: | AUTO |
Default: | 15 seconds |
Max value: | 60 seconds |
PN 2110036 Revision 1.0 | 05/11/99 |