RAD Data comm ASM-10/8 operation manual Installation and Setup, Setting, Internal Jumpers

Page 26

Chapter 2. Installation and Setup

ASM-10/8Installation and Operation Manual

 

 

 

 

 

 

 

 

 

2.3 Installation and Setup

ASM-10/8 is a standalone device intended for tabletop or bench installation.

It is delivered completely assembled. No provisions are made for bolting the

ASM-10/8 to the tabletop. For installation of the unit in a 19" rack, refer to

Appendix B.

To complete the installation of ASM 10/8:

1.Determine the required configuration of the modem according to your application, and set the internal jumpers and switches accordingly (see Figure 2-1and Table 2-1.

2.Connect the line (see Connecting the Line below).

3.Connect the DTE interface (see Connecting the DTE below).

4.Connect power to the unit (see Connecting the Power below).

Setting the

This section provides information on the functions of the internal jumpers

Internal Jumpers

and switches, to help you in the selection of the correct settings for

 

particular application, and gives you step-by-step instructions for

 

performing the internal settings. The default settings are also listed.

To set the ASM-10/8 internal jumpers:

Warning

Caution

1.Open the ASM-10/8 case.

2.Set the ASM-10/8 internal jumpers and switches, referring to Figure 2-1.

3.Reinstall the ASM-10/8 cover.

Access to the inside of the equipment is permitted only to the authorized and qualified personnel.

To avoid accidental electric shock, always disconnect the interface cables and the power cord before removing the unit from its casing.

Line voltages are present inside ASM-10/8 when it is connected to power and/or the lines. Moreover, under certain fault conditions, dangerous voltages may appear on the lines connected to the unit.

Any adjustment, maintenance and repair of the opened instrument under voltage must be avoided as much as possible and, when inevitable, should be carried out only by a skilled technician who is aware of the hazard involved. Capacitors inside the unit may still be charged even after the unit has been disconnected from its source of power.

ASM-10/8 contains components sensitive to electrostatic discharge (ESD). To prevent ESD damage, avoid touching the internal components, and before moving jumpers, touch the ASM-10/8 frame.

2-2 Installation and Setup

Image 26 Contents
ASM-10/8 International Headquarters RAD Data Communications IncPage Warranty Safety Warnings Safety Status PortsSafety Supplementary InformationPage Jumper Settings QS.1 Installing ASM-10/8Switch Jumper Possible Settings Default SettingRPF OFF QS.2 Operating ASM-10/8 Quick Start Guide Operating ASM-10/8 Rqwhqwv +$3757528%/6+227,1*$1,$*1267,&6 Lvwriljxuhv LVWRI7DEOHV General Power Supply VersionsOverview VersionsApplications ASM-10/8 Point-to-Point ApplicationFeatures Transmission Range Speed 19 AWG 24 AWG 26 AWGPhysical Description ASM-10/8 Standalone UnitFunctional Description Receiver Remote Power Failure RPF Indication Diagnostics ASM-10/8 Block Diagram 6shows the ASM-10/8 internal circuitryTechnical Specifications LineEnvironment Package Contents Site Requirements and PrerequisitesTo complete the installation of ASM 10/8 Installation and SetupSetting Internal JumpersTo open the ASM-10/8 case Setting the Internal Jumpers and SwitchesOpening the ASM-10/8 Case 600 300 150 Jumper Description Values Default SettingDbm 300 High Msec Msec8 msec Data Rate Selects the data rate 14.4No of bits Configuration ConsiderationsSetting AGC and CTS Delay Start Bit Data Bits Parity Stop Bit No of Bits Setting the Async Character LengthSetting the V.54 Delay Connecting the DTE Connecting the PowerKdswhu 2SHUDWLRQ $60IURQWSDQHOLQGLFDWRUVDQGFRQWUROV2SHUDWLQJ,QVWUXFWLRQV VrxufhKdswhu Lqwhuidfh LJXUH/RFDOLJLWDO/RRSEDFN LJXUH5HPRWHLJLWDO/RRSEDFN³ 7RDFWLYDWHWKH5HPRWHLJLWDO/RRSEDFN ³ 7RSHUIRUPWKH/RFDOLJLWDO/RRSEDFN Kdswhu DUG&DJH9HUVLRQ 6HFWLRQGHVFULEHVKRZWRLQVWDOO$605$605&DUG9HUVLRQ 3RZHU6XSSO\ RU9$ 6XSSO\ VkrxogerwkoljkwzkhqpdlqvsrzhulvsurylghgDQG7DEOHLQ&KDSWHU RxwohwKDSWHU&DUG&DJH9HUVLRQ $SSHQGL$ Rqqhfwrululqj 7DEOH$7,QWHUIDFH3LQ$VVLJQPHQWV7DEOH$7,QWHUIDFH3LQ$VVLJQPHQWV&RQW 7HVW&RPPDQG³ 7RLQVWDOODVLQJOHXQLW DuqlqjUdfn LVFRQQHFW$&SRZHUEHIRUHRSHQLQJWKHXQLW LJXUH%,QVWDOODWLRQRID6LQJOH8QLW UDFNVHHLJXUH%LJXUH%,QVWDOODWLRQRI7ZR8QLWV ³ 7RLQVWDOOWZRXQLWV VfuhzvvxssolhgLJXUH%DVWHQLQJ7ZR8QLWV7RJHWKHU
Related manuals
Manual 50 pages 45.96 Kb