Chapter 2. Installation and Setup

 

 

Opening the ASM-10/8 Case

To reach the internal jumpers and switches of ASM-10/8, it is necessary to open its case.

To open the ASM-10/8 case:

1.Disconnect all the cables connected to ASM-10/8.

2.Turn the unit over (bottom facing up).

3.Unscrew the four cover screws.

4.Turn the unit over (bottom facing down).

5.After the four screws released, remove the ASM-10/8 top cover by pulling it straight up.

Setting the Internal Jumpers and Switches

The internal jumpers and switches located on the ASM-10/8 printed circuit board (PCB) are identified in Figure 2-1. Their numbers under heading "Item" in Table 2-1correspond to the identification numbers shown in Figure 2-1.

16

 

 

15

 

 

14

13

12

 

11

 

10

 

V.54-DLY

S3

S4

LEN

S2(%)

 

 

 

 

 

 

 

CHAS GND

 

OFF OFF 8 BIT

ON=25%

7 0 1

CTS-DLY

 

RCV IMPD

GND

ON OFF

 

 

DIS CONN

OFF ON

9 BIT

 

 

6

2

0 ms 8 ms

64 ms

 

150 300 600 HIGH

 

 

 

ON

OFF 10 BIT

 

 

5 4 3

 

 

RCV

 

ON

ON

11 BIT OFF=12.5%

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

XMT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S3

 

 

 

 

 

 

XMT IMPD

 

 

 

 

 

 

 

S4

 

 

 

 

XMT LEVEL

 

 

PIN 18

 

 

 

 

 

 

XMT TIMING

600 300 150 LOW

 

 

 

 

 

 

 

 

0 dbm -3 dbm -6 dbm -9 dbm

 

 

EN DIS

 

 

 

 

 

 

INT EX RCV ASY

 

 

 

 

 

 

 

 

 

 

 

 

 

DTE

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN 21

 

 

 

 

 

 

 

 

 

 

 

RPF

 

 

EN DIS

 

 

SWITCH

 

2W/4W

 

CARRIER

 

 

 

 

 

 

 

 

 

 

 

ON OFF

 

 

 

 

 

EN DIS

 

2W 4W

 

CTRL ON

 

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AGC

 

 

 

 

 

 

 

Fuse

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CTRL ON

 

 

 

 

 

 

 

 

 

1

 

 

2

3

 

4

5

6

7

 

8

9

 

 

 

 

 

Figure 2-1

ASM-10/8 PCB Layout

 

 

 

 

 

Installation and Setup

2-3

Image 27
Contents International Headquarters RAD Data Communications Inc ASM-10/8Page Warranty Safety Status Ports Safety WarningsSupplementary Information SafetyPage Jumper Possible Settings Default Setting QS.1 Installing ASM-10/8Switch Jumper SettingsRPF OFF QS.2 Operating ASM-10/8 Quick Start Guide Operating ASM-10/8 Rqwhqwv +$3757528%/6+227,1*$1,$*1267,&6 Lvwriljxuhv LVWRI7DEOHV Versions Power Supply VersionsOverview GeneralASM-10/8 Point-to-Point Application ApplicationsFeatures Speed 19 AWG 24 AWG 26 AWG Transmission RangeASM-10/8 Standalone Unit Physical DescriptionFunctional Description Receiver Remote Power Failure RPF Indication Diagnostics 6shows the ASM-10/8 internal circuitry ASM-10/8 Block DiagramLine Technical SpecificationsEnvironment Site Requirements and Prerequisites Package ContentsInternal Jumpers Installation and SetupSetting To complete the installation of ASM 10/8Setting the Internal Jumpers and Switches Opening the ASM-10/8 CaseTo open the ASM-10/8 case Jumper Description Values Default Setting Dbm600 300 150 Msec Msec8 msec Data Rate Selects the data rate 14.4 300 HighConfiguration Considerations Setting AGC and CTS DelayNo of bits Setting the Async Character Length Setting the V.54 DelayStart Bit Data Bits Parity Stop Bit No of Bits Connecting the Power Connecting the DTE$60IURQWSDQHOLQGLFDWRUVDQGFRQWUROV Kdswhu 2SHUDWLRQVrxufh 2SHUDWLQJ,QVWUXFWLRQVKdswhu Lqwhuidfh LJXUH5HPRWHLJLWDO/RRSEDFN ³ 7RDFWLYDWHWKH5HPRWHLJLWDO/RRSEDFNLJXUH/RFDOLJLWDO/RRSEDFN ³ 7RSHUIRUPWKH/RFDOLJLWDO/RRSEDFN 6HFWLRQGHVFULEHVKRZWRLQVWDOO$605 Kdswhu DUG&DJH9HUVLRQ$605&DUG9HUVLRQ 3RZHU6XSSO\ Vkrxogerwkoljkwzkhqpdlqvsrzhulvsurylghg RU9$ 6XSSO\Rxwohw DQG7DEOHLQ&KDSWHUKDSWHU&DUG&DJH9HUVLRQ 7DEOH$7,QWHUIDFH3LQ$VVLJQPHQWV $SSHQGL$ Rqqhfwrululqj7HVW&RPPDQG 7DEOH$7,QWHUIDFH3LQ$VVLJQPHQWV&RQWDuqlqj Udfn LVFRQQHFW$&SRZHUEHIRUHRSHQLQJWKHXQLW³ 7RLQVWDOODVLQJOHXQLW UDFNVHHLJXUH% LJXUH%,QVWDOODWLRQRID6LQJOH8QLWVfuhzvvxssolhg LJXUH%,QVWDOODWLRQRI7ZR8QLWV ³ 7RLQVWDOOWZRXQLWVLJXUH%DVWHQLQJ7ZR8QLWV7RJHWKHU

ASM-10/8 specifications

The RAD DataComm ASM-10/8 is a versatile and robust network access and service management solution designed for telecom operators and service providers. It serves as an essential tool for enhancing the efficiency and performance of data communication networks, particularly in environments that require high reliability and real-time service delivery.

One of the key features of the ASM-10/8 is its ability to seamlessly integrate with various existing network infrastructures. This flexibility allows operators to bolster their services without the need for a complete overhaul of their systems. The ASM-10/8 supports multiple protocols, making it compatible with a wide range of technologies, including Ethernet, T1/E1, and more, ensuring that it can be used effectively in diverse scenarios.

The ASM-10/8 is characterized by its advanced management capabilities. It comes equipped with a powerful network management system that enables real-time monitoring and configuration of network elements. This functionality provides operators with significant insights into network performance, enabling them to address issues proactively and maintain consistent service quality.

In terms of scalability, the ASM-10/8 is designed to accommodate growing network demands. Its modular architecture allows for easy upgrades and expansions, enabling service providers to quickly adapt to changing requirements. This scalability is particularly important in today’s fast-paced digital landscape, where the ability to provide additional bandwidth or services can be a competitive advantage.

Security is another critical aspect of the ASM-10/8. The device integrates robust security features, including encryption and access controls, ensuring that sensitive data is protected. This focus on security not only safeguards customer information but also helps maintain compliance with regulatory standards.

Moreover, the ASM-10/8 supports a range of advanced technologies such as Quality of Service (QoS) mechanisms, which prioritize traffic to ensure that critical applications receive the necessary bandwidth. This capability is essential for delivering high-quality services, especially in environments with heavy data traffic.

In conclusion, the RAD DataComm ASM-10/8 represents a powerful solution for modern telecom operators and service providers. Its combination of flexibility, scalability, robust management capabilities, and security features make it an ideal choice for organizations looking to enhance their data communication services. With the ability to adapt to evolving technologies and customer needs, the ASM-10/8 is poised to support the growth and success of network operators in an increasingly digital world.