Dell SC1425 System and Setup Password Features, Console Redirection Screen, Exit Screen

Page 21

Password

Setting the Setup Password option to Enabled prevents the system password from being changed or disabled at system start-up.

Status

 

 

To lock the system password, assign a setup password in the Setup Password option and then change the Password Status option to

 

Locked. In this state, you cannot change the system password using the System Password option and cannot disable at system start up by

 

pressing <Ctrl><Enter>.

 

To unlock the system password, enter the setup password in the Setup Password field and then change the Password Status option to

 

Unlocked. In this state, you can disable the system password at system start up by pressing <Ctrl><Enter> and then change the password

 

using the System Password option.

 

 

Power Button

Turns the system's power off and on.

(Enabled

 

default)

If you turn off the system using the power button and the system is running an ACPI-compliant operating system, the system can

 

 

perform an orderly shutdown before power is turned off.

 

If the system is not running an ACPI-compliant operating system, power is turned off immediately after the power button is pressed.

 

The button is enabled in the System Setup program. When disabled, the button can only turn on system power.

 

 

NMI Button

 

(Disabled

 

default)

NOTICE: Use the NMI button only if directed to do so by qualified support personnel or by the operating system's documentation. Pressing

 

 

this button halts the operating system and displays a diagnostic screen.

 

Sets the NMI feature to Enabled or Disabled.

 

 

AC Power

Determines how the system reacts when power is restored to the system. If the option is set to Last, the system returns to the last power

Recovery

state. On turns on the system after power is restored. When set to Off, the system remains off after power is restored.

(Last default)

 

 

 

Console Redirection Screen

Table 3-6 lists the options and descriptions for the information fields that appear on the Console Redirection screen. For more information about using console redirection, see "Using Console Redirection."

Table 3-6. Console Redirection Screen Options

Option

Description

 

 

Console Redirection

Sets the console redirection feature to Serial Port 1 or Off.

(Off default)

 

 

 

Failsafe Baud Rate

Displays if the failsafe baud rate is used for console redirection.

(11520 default)

 

 

 

Remote Terminal Type

Select either VT 100/VT 220 or ANSI.

(VT 100/VT 220 default)

 

Redirection After Boot

Enables or disables console redirection after your system restarts.

(Enabled default)

 

Exit Screen

After you press <Esc> to exit the System Setup program, the Exit screen displays the following options:

Save Changes and Exit

Discard Changes and Exit

Return to Setup

System and Setup Password Features

NOTICE: The password features provide a basic level of security for the data on your system. If your data requires more security, use additional forms of protection, such as data encryption programs.

NOTICE: Anyone can access the data stored on your system if you leave the system running and unattended without having a system password assigned or if you leave your system unlocked so that someone can disable the password by changing a jumper setting.

Your system is shipped to you without the system password feature enabled. If system security is a concern, operate your system only with system password protection.

To change or delete an existing password, you must know the password (see "Deleting or Changing an Existing System Password"). If you forget your password, you cannot operate your system or change settings in the System Setup program until a trained service technician changes the password jumper setting to disable the passwords, and erases the existing passwords. This procedure is described in the Installation and Troubleshooting Guide.

Using the System Password

After a system password is assigned, only those who know the password have full use of the system. When the System Password option is set to Enabled, the system prompts you for the system password after the system starts.

Image 21
Contents Abbreviations and Acronyms Dell PowerEdge SC1425 Systems Users GuideTechnical Specifications Environmental Temperature Power AC power supply per power supplyBatteries PhysicalConfiguring the Host System Using Console RedirectionConfiguring the Client System Hardware RequirementsConfiguring the Terminal Settings Configuring Special Key FunctionsClick Terminal Setup Managing the Host System RemotelyTable B-2. Additional Escape Sequences Table B-1. Supported Escape SequencesKeys Supported Sequence Terminal Emulation Keys Supported SequenceBack to Contents Dell PowerEdge SC1425 Systems Users Guide RAID Page Warranty Front-Panel Features and Indicators Indicator, Button Icon Description Or ConnectorSystem Overview Back-Panel Features and Indicators System FeaturesConnecting External Devices Power Protection Devices Supported Operating SystemsOther Documents You May Need Obtaining Technical Assistance Using the Server Setup Program Using the Dell OpenManage Server AssistantStarting the Server Assistant CD Updating Drivers and UtilitiesUsing the Utility Partition Utility Partition Main Menu OptionsOption Description Using the System Setup Program Entering the System Setup ProgramSystem Setup Options CPU Information Screen System Setup Program OptionsSystem Security Screen Integrated Devices ScreenCPU Information Screen Integrated Devices Screen OptionsUsing the System Password System and Setup Password FeaturesConsole Redirection Screen Exit ScreenAssigning a System Password Using the Setup Password Disabling a Forgotten PasswordEntering the BMC Setup Module Baseboard Management Controller ConfigurationAsset Tag Utility Creating the Asset Tag Utility DisketteBMC Setup Module BMC Setup Module OptionsDIN Deutsche Industrie Norm GlossaryPage Page System memory See RAM ZIF Zero insertion force Dell PowerEdge SC1425 Systems Users Guide