Dell R610 owner manual 177

Page 177

virtualization — The ability via software to share the resources of a single computer across multiple environments. A single physical system may appear to the user as multiple virtual systems able to host multiple operating systems.

W — Watt(s).

WH — Watt-hour(s).

XML — Extensible Markup Language. XML is a way to create common information formats and to share both the format and the data on the World Wide Web, intranets, and elsewhere.

ZIF — Zero insertion force.

Glossary

177

Image 177
Contents Dell PowerEdge R610 Systems September Contents Entering the Uefi Boot Manager Processor Settings ScreenUefi Boot Settings Screen Using the System Password Using the Setup PasswordEntering the iDRAC Configuration Utility Installing a Hard Drive Into aExpansion Card Installation Guidelines Contents Installing the Internal SD Module Installing an Expansion Card Removing an Expansion CardInstalling an Internal SD Flash Card Installing a VFlash Media CardGeneral Memory Module Installation Installing the Integrated StorageReplacing the System Battery 127 Replacing the Plastic Fan Guide 108148 Troubleshooting Your System 141159 Disabling a Forgotten Password 163163 163167 You to select a boot device Accessing System Features During StartupYou to manage your system’s boot options F11Front-Panel Features and Indicators System error messages USB connectorsLCD panel displays an error Operating systems documentationOptional Or DVD+RW drive System identification LCD Panel FeaturesHome Screen Seconds to enter Bios Progress modeButtons Description Left Hold the system ID button for more than fiveView Menu Setup MenuHard-Drive Indicator Patterns for RAID Option Description TemperatureAmber During this time Connects a VGA display to the system Back-Panel Features and IndicatorsIndicator, Button, or Icon Power supply 1 PS1Power supply 2 PS2 Power Indicator Codes Link indicator NIC Indicator CodesLCD Status Messages Viewing Status MessagesRemoving LCD Status Messages Disabled ErrorRange. Power BatteryFault. Power E122C CPU PowerE1216 RegulatorE1311 Fan module ## ConfigurationRPM exceeding E1313 FanParity error Error. PowerPower cycle Check errorPower. Check E161C Power SupplyE1624 Lost power E1626 Power SupplyE1710 Channel Error on BusReview Clear SELE1714 Unknown Error. ReviewE1715 Fatal I/O E1716 Chipset IerrReconfigure Fault. ReviewE171F PCIe fatal E1810 Hard drive ##But unusable Check DIMMs E2013 Bios unable ConfiguredE1A15 SAS cable B Control panelTimer error E2017 Timer refreshE2019 Parity error E2015E201B Keyboard ConfigurE201C InitializatioDisabled on Error on DimmE2110 Multibit ##. ReseatW1228 W1627 PowerCapacity 24hrSystem Messages Power required RebootingSystem boot Alert! iDRAC6 notMemory disabled Alert! PowerFatal error BootIs installed on Bios UpdateCPU x installed Attempt FailedConfiguration on Bootable media isCPUs with Different cachePlease run Setup Correct Connectors Gate A20 failureEmbedded NICx NICyFound Invalid PCIe cardInternalStorage SlotLine failure at Memory addressValue expecting Memory doubleNo timer tick Mirror modeDIMMs must be AvailableTo install PCI Bios failedError Expected PCIe TrainingSeek error Read faultRequested sector Not foundAmount Shutdown failureSystem memory has ChangedDIMMs should Setup programFollowing DIMMs should Following DIMMs should Match in sizeWill now reset Timer chipSystem Services Counter 2 failedUnexpected Protected modeUnsupported CPU CombinationSystem reset Error has causedInstalled Code updateNot optimal. Recommended Memory Configuration Configuration isWrite fault Write fault on selected drive Mismatch. PSUAlert Messages Diagnostics MessagesOther Information You May Need About Your System Choosing the System Boot Mode Using the System Setup Program and Uefi Boot ManagerResponding to Error Messages Entering the System Setup ProgramUsing the System Setup Program Navigation Keys System if any changes were madeSize, and so on. See Processor Settings Screen System Setup OptionsMain Screen See Integrated Devices ScreenErrors On default To 84-key keyboards Report KeyboardReport default This setting does not affect the operation of the keyboardProcessor Settings Screen Memory Settings ScreenExecute Disable Sata Settings ScreenEnabled default Available power states Processor X ID Cache size, and number of cores of each processorBoot Settings Screen Integrated Devices Screen Serial Communication Screen PCI IRQ Assignments ScreenAttempt fails. This rate should not be adjusted Power Management ScreenEnabled default Operating system is loaded You can configure each option independentlyMemory power to Maximum Performance. In this DBPM, the fan power to Minimum Power,If you select Custom, you can configure each option Fan PowerSystem Security Screen Exit Screen Enables or disables the NMI featureUsing the Uefi Boot Manager Navigation Keys Entering the Uefi Boot ManagerDisplays the Uefi Boot Manager help file One or returns to the previous screenUefi Boot Settings Screen Uefi Boot Manager ScreenSystem and Setup Password Features Using the System PasswordSystem Utilities Screen Using the System Setup Program and Uefi Boot Manager Using the Setup Password Using the System Setup Program and Uefi Boot Manager Entering the iDRAC Configuration Utility IDRAC Configuration UtilityInstalling System Components Recommended ToolsInside the System Removing and Replacing the Optional Front Bezel Removing the Information Tag Information TagOpening and Closing the System Replacing the Information TagOpening the System Lift up the latch on the cover Closing the SystemRemoving a Drive Blank Hard DrivesInstalling a Hard-Drive Blank Removing a Hot-Swap Hard DriveRemove the front bezel. See Removing the Front Bezel Installing a Hot-Swap Hard Drive Hard drive Drive carrier Installing a Hot-Swap Hard DriveRemoving a Hard Drive From a Hard-Drive Carrier Installing a Hard Drive Into a Hard-Drive CarrierSAS screw hole Removing a Power Supply Power SuppliesRemoving and Replacing a Power Supply Power supply Installing a Power SupplyInstalling the Power Supply Blank Removing the Power Supply BlankExpansion Card Installation Guidelines Expansion CardsInstalling an Expansion Card Close the expansion-card latch. See Figure Expansion-Card Risers Removing an Expansion CardRemoving an Expansion-Card Riser Installing System Components Page Internal SD Module Installing the Internal SD ModuleReplacing an Expansion-Card Riser Opposite side of riserBoard Installing an Internal SD Flash Card Internal SD Flash CardRemoving the Internal SD Module Card Removing an Internal SD Flash Card Internal USB Memory KeyInternal USB Cable Removing the Internal USB CableUSB memory key Remove the USB cable from the connector on the system board Installing the Internal USB CableVFlash Media 100Installing an iDRAC6 Enterprise Card Installing a VFlash Media CardIDRAC6 Enterprise Card Optional Removing a VFlash Media CardRetention standoff posts Socket Removing an iDRAC6 Enterprise Card103 NIC Hardware KeyCooling Fans 13. Installing a NIC Hardware Key NIC hardware keyFan assembly Installing System Components Removing a Cooling Fan105 Replacing a Cooling Fan Removing the Fan AssemblyReplacing the Fan Assembly 107Only Optical Drive Removing the Plastic Fan GuideReplacing the Plastic Fan Guide 109 Removing an Optical Drive16. Removing the Optical Drive Optical drive Installing an Optical DriveIntegrated Storage Controller Card Removing the Integrated Storage Controller Card111 Intstorage Installing the Integrated Storage Controller CardSAS data cable Cable retention clip 113Removing a RAID Battery RAID BatteryInstalling a RAID Battery Removing the Perc 6/I Battery Cable115 Installing the Perc 6/I Battery CableSystem Memory General Memory Module Installation Guidelines117 Mode-Specific Guidelines118 None All Mirroring 119Mirroring None Installing Memory Modules121 18. Installing and Removing a Memory Module Memory moduleRemoving Memory Modules ProcessorsRemoving a Processor 122123 19. Installing and Removing the Heat Sink Heat sinkInstalling System Components 125 Installing a ProcessorInstalling System Components System Battery Replacing the System Battery127 21. Replacing the System Battery Control Panel Assembly Removing the Control Panel Display Module129 Mounting screws 3 Torx Installing the Control Panel Display Module Removing the Control Panel Board131 Installing the Control Panel Board SAS BackplaneRemoving the SAS Backplane 133 134 System Board Installing a SAS BackplaneRemoving the System Board 135Installing System Components 137 24. Removing and Installing the System Board Retention pinInstalling the System Board 139 140 Troubleshooting External Connections Troubleshooting Your System141 Troubleshooting a USB Device Troubleshooting the Video SubsystemTroubleshooting a Serial I/O Device Troubleshooting a NIC143 Troubleshooting a Wet System 145 Troubleshooting a Damaged SystemTroubleshooting Power Supplies Troubleshooting the System BatteryTroubleshooting System Cooling Problems Ensure that none of the following conditions exist147 Troubleshooting System Memory Troubleshooting a Fan149 Troubleshooting an Internal SD Card Troubleshooting an Internal USB Key Troubleshooting an Optical Drive151 Troubleshooting Hard Drives 153 Troubleshooting a SAS ControllerTry using a different tape cartridge 154 Troubleshooting an External Tape Drive155 Troubleshooting Expansion Cards156 157 Troubleshooting the ProcessorsTroubleshooting Your System System Diagnostics Features Using Dell PowerEdge DiagnosticsRunning the System Diagnostics When to Use the System DiagnosticsUsing the Custom Test Options System Diagnostics Testing OptionsSelecting Devices for Testing Selecting Diagnostics OptionsViewing Information and Results System Board Jumper Settings Disabling a Forgotten PasswordJumpers and Connectors System Board JumpersSystem Board Connectors 165 System Board Connectors Jumpers and Connectors166 167 Contacting Dell168 169 Amperes AC Alternating currentGlossary CPU Central processing unit. See processor DC Direct current 170171 172 173 174 System memory See RAM 175176 177 178 Index 179Using Dell PowerEdge Diagnostics Diagnostics Advanced testing options, 161 testing optionsMicroprocessor See processor 181SD card, 98 system board Post183 System Utilities screen, 72 Uefi Boot Settings screen Front-panel connectors USB cable internal
Related manuals
Manual 56 pages 37.07 Kb Manual 210 pages 41.43 Kb Manual 184 pages 22.08 Kb Manual 4 pages 41.72 Kb

R610 specifications

The Dell PowerEdge R610 is a 1U rack server that combines outstanding performance with advanced management features, making it ideal for enterprises and small to medium-sized businesses. Introduced as part of Dell’s 11th generation of servers, the R610 is designed to meet demanding workloads while optimizing energy consumption.

One of the main features of the R610 is its dual-socket capability, supporting up to two Intel Xeon 5500 or 5600 series processors. This allows significant scaling of compute power, enabling users to run multiple applications concurrently without a hitch. The server supports up to 192 GB of DDR3 memory with 18 DIMM slots, providing ample bandwidth for memory-intensive workloads.

Storage flexibility is another hallmark of the R610. It offers a choice of up to six 2.5-inch SAS, SATA, or solid-state drives, which allows for impressive storage capacities and the option for RAID configurations. This ensures data integrity and high availability, catering to the needs of various applications from databases to virtual environments.

The Dell R610 introduces advanced virtualization technologies, with support for VMware and Microsoft Hyper-V, making it an excellent choice for virtualized environments. With the option to deploy multiple virtual machines on a single physical server, organizations can maximize resource allocation and reduce costs.

In terms of management, the R610 is equipped with the Integrated Dell Remote Access Controller (iDRAC) which provides out-of-band management capabilities. This feature allows administrators to monitor system health, perform firmware updates, and manage hardware without the need for physical access to the server.

Energy efficiency is a notable characteristic of the R610, complying with Energy Star requirements. It utilizes lower power consumption components and features such as dynamic power management, which adjusts the power usage based on real-time workload demand. This characteristic contributes to lower operational costs and a reduced environmental footprint.

The Dell PowerEdge R610 excels in providing an optimal balance of performance, manageability, and energy efficiency, making it a powerful tool for IT environments that demand reliability and scalability. Its robust feature set and support for virtualization technologies position it as a favorable choice for businesses looking to enhance their IT infrastructure efficiently.