Dell R420, E18S001 owner manual Integrated Devices Screen

Page 27

Integrated Devices Screen

Menu Item

Description

Integrated RAID

Allows you to enable or disable the integrated RAID controller. By default, the Integrated RAID

Controller

Controller option is set to Enabled.

User Accessible USB

Allows you enable or disable the user accessible USB ports. Selecting Only Back Ports On

Ports

disables the front USB ports and selecting All Ports Off disables both front and back USB ports.

 

By default, the User Accessible USB Ports option is set to All Ports On.

Internal USB Port

Allows you to enable or disable the internal USB port. By default, the Internal USB Port option

 

is set to On.

Internal SD Card Port

Enables or disables the system’s internal SD card port. By default, Internal SD Card Port option

 

is set to On.

 

NOTE: This option is displayed only if IDSDM is installed on the system board.

Internal SD Card

If set to Mirror mode, data is written on both SD cards. If any one of the SD card fails, data is

Redundancy

written to the active SD card. Data from this card is copied to the replacement SD card at the

 

next boot. By default, Internal SD Card Redundancy option is set to Mirror.

 

NOTE: This option is displayed only if IDSDM is installed on the system board.

Integrated Network

Allows you to enable or disable the integrated network card 1. By default, the Integrated

Card 1

Network Card 1 option is set to Enabled.

OS Watchdog Timer

Allows you to enable or disable the OS watchdog timer. When this field is enabled, the

 

operating system initializes the timer and the OS watchdog timer helps in recovering the

 

operating system. By default, the OS Watchdog Timer option is set to Disabled.

Embedded Video

Allows you to enable or disable the Embedded Video Controller. By default, the embedded

Controller

video controller is Enabled.

SR-IOV Global Enable

Allows you to enable or disable the BIOS configuration of Single Root I/O Virtualization (SR-

 

IOV) devices. By default, the SR-IOV Global Enable option is set to Disabled.

Slot Disablement

Allows you to enable or disable available PCIe slots on your system. The Slot Disablement

 

feature controls the configuration of PCIe cards installed in the specified slot.

 

CAUTION: Slot disablement must be used only when the installed peripheral card is

 

preventing booting into the Operating System or causing delays in system startup. If the

 

slot is disabled, both the Option ROM and UEFI driver are disabled.

Memory Mapped I/O

Allows you to enable support for PCIe devices that require large amounts of memory. By

above 4 GB

default, the option is set to Enabled.

27

Image 27
Contents Regulatory Model E18S Series Regulatory Type E18S001 Dell Inc. All Rights Reserved Contents Installing Memory Modules Installing System ComponentsInstalling The Optical Drive In Cabled Hard-Drive Systems 105 Troubleshooting Your SystemSystem Messages Using System DiagnosticsJumpers And Connectors Technical SpecificationsPage Indicator, Button, or Icon Description Connector Front-Panel Features And IndicatorsFollowed by descriptive text System ButtonPressed again LCD Panel FeaturesButton Description Setup MenuSet error Home ScreenView Menu Diagnostic IndicatorsHard-drive indicator Condition Electrical indicator ConditionMemory indicator Corrective Action Drive-Status Condition Indicator Pattern RAID Only Hard-Drive Indicator PatternsPCIe indicator Condition ErrorSeconds Back-Panel Features And IndicatorsNIC Indicator Codes Power Indicator CodesGreen Link indicator is Other Information You May Need Page F11 F12 Choosing The System Boot ModeKeystroke Description F10Entering System Setup Responding To Error MessagesUsing The System Setup Navigation Keys System Information Screen System Setup OptionsSystem Setup Main Screen System Bios ScreenProcessor Settings Screen Memory Settings ScreenExecute Disable option is set to Enabled Option is set to EnabledPrefetcher option is set to Enabled Execute DisableBoot Settings Screen Sata Settings ScreenIntegrated Devices Screen Serial Communications Screen System Profile Settings ScreenSystem Security Screen Miscellaneous Settings System And Setup Password FeaturesAssigning a System And/Or Setup Password Deleting Or Changing An Existing Setup Password Using Your System Password To Secure Your SystemOperating With a Setup Password Enabled Displays the System Setup help file Entering The Uefi Boot ManagerUsing The Boot Manager Navigation Keys Exits the Boot Manager and proceeds with system bootIDRAC Settings Utility Boot Manager ScreenEmbedded System Management Changing The Thermal Settings Entering The iDRAC Settings UtilityPage Installing The Front Bezel Recommended ToolsFront Bezel Optional Opening And Closing The System Removing The Front BezelOpening The System Closing The System Inside The SystemHeat sink for processor Inside the System-With Redundant Power Supplies Removing The Cooling Shroud Cooling ShroudSystem Memory Installing The Cooling ShroudMemory Socket Locations ProcessorMode-Specific Guidelines General Memory Module Installation GuidelinesMemory Optimized Independent Channel Mode Sample Memory Configurations2R x4, 1600 MT/s 2R x4, 1333 MT/s Ejecting The Memory Module Removing Memory ModulesRemoving The Memory Module Installing Memory ModulesHard Drives Four hard-driveSystems Installing a 2.5 Inch Hard-Drive Blank Removing a 2.5 Inch Hard-Drive BlankSystemsdrives Installing a 3.5 Inch Hard-Drive Blank Removing a 3.5 Inch Hard-Drive BlankRemoving a Hot-Swap Hard Drive Removing and Installing a Hot-Swap Hard Drive Installing a Hot-Swap Hard DriveRemoving a Cabled Hard Drive Removing and Installing a Cabled Hard DriveInstalling a Cabled Hard Drive Screws Inch hard-drive adapter Inch hard drive Hard-drive carrier Screws Hard drive Screw holes Page Screws Hard drive Screw holes Hard-drive carrier Optical Drive Optional Removing The Optical Drive In Cabled Hard-Drive Systems Installing The Optical Drive In Cabled Hard-Drive Systems Removing a Cooling Fan Cooling FansRemoving and Installing a Cooling Fan Installing a Cooling FanInternal USB Memory Key Optional Expansion Cards And Expansion-Card RisersReplacing The Internal USB Key Height Expansion Card Installation GuidelinesExpansion Card Connector RiserRemoving An Expansion Card Installing An Expansion Card Removing Expansion-Card Risers 1 Removing and Installing the Expansion-Card RiserIDRAC Ports Card Optional Installing Expansion-Card Risers 1Removing The iDRAC Ports Card Removing and Installing the iDRAC Ports CardInstalling The iDRAC Ports Card SD vFlash CardReplacing An SD vFlash Card Removing The Internal Dual SD Module Internal Dual SD ModuleRemoving and Installing the Internal Dual SD Module Installing The Internal Dual SD ModuleRemoving An Internal SD Card Installing An Internal SD CardInternal SD Card Integrated Storage Controller CardRemoving The Integrated Storage Controller Card Installing The Integrated Storage Controller Card ProcessorsRemoving a Processor Removing and Installing the Processor Heat Sink Removing and Installing a Processor Installing a ProcessorPower Supplies Removing a Redundant Power Supply Hot Spare FeatureRemoving a Non-Redundant Power Supply Installing a Redundant Power SupplyRemoving and Installing a Non-Redundant Power Supply Installing a Non-Redundant Power SupplyReplacing The System Battery System BatteryRemoving The Power Supply Blank Installing The Power Supply BlankHard-Drive Backplane Replacing the System BatteryFront View of the Four Hard-Drive Backplane Removing The Hard-Drive BackplaneRelease tabs Hard-drive backplane Guide pins Chassis hooks System board Hard-drive backplane Release tabs Chassis hooks Installing The Hard-Drive Backplane Control Panel AssemblyRemoving The Control Panel Installing The Control Panel Removing The Control-Panel Module LED-panel screws Control-panel module Installing The Control-Panel Module Removing The VGA Module VGA ModulePower Distribution Board Shroud Installing The VGA ModuleRemoving The Power Distribution Board Shroud Removing and Installing the PDB Shroud Installing The Power Distribution Board ShroudRemoving The Power Distribution Board Power Distribution BoardInstalling The Power Distribution Board System BoardRemoving The System Board Removing and Installing the System Board Installing The System BoardPage 104 Troubleshooting External Connections Troubleshooting The Video SubsystemTroubleshooting a USB Device Troubleshooting a NIC Troubleshooting a Serial I/O DeviceTroubleshooting a Damaged System Troubleshooting a Wet SystemTroubleshooting The System Battery Troubleshooting Power SuppliesTroubleshooting Cooling Problems Troubleshooting System Memory Troubleshooting Cooling FansTroubleshooting An SD Card Troubleshooting An Internal USB KeyTroubleshooting a Tape Backup Unit Troubleshooting An Optical DriveTroubleshooting a Storage Controller Troubleshooting a Hard DriveTroubleshooting Expansion Cards Troubleshooting Processors Dell Online Diagnostics Dell Embedded System Diagnostics When To Use The Embedded System DiagnosticsRunning The Embedded System Diagnostics Least one event description is recorded System Diagnostic ControlsJumper Setting Description System Board Jumper SettingsConnector Description System Board ConnectorsDisabling a Forgotten Password 120 Drives Expansion slots using riser cardExpansion Bus MemoryVideo Connectors BackFront InternalRelative Humidity Expanded Operating TemperatureEnvironmental Temperature Temperature Continuous OperationMaximum Altitude EnvironmentalMaximum Vibration Maximum ShockGaseous Contamination 126 Removing LCD Messages System Error MessagesLCD Messages Viewing LCD MessagesAction Error CodeAMP0302 Message DetailsCPU0000 Message ASR0003 MessageBAT0002 Message BAT0017 MessageCPU0700 Message CPU0010 MessageCPU0023 Message CPU0204 MessageCPU0702 Message CPU0703 MessageCPU0704 Message Details Fan operating speed is out of range Action If the issue persists, see Getting HelpAction Reinstall or reconnect the hardware HWC2003 Message FAN0000 MessageMEM0701 Message MEM0000 MessageMEM0001 Message MEM0007 MessagePCI1304 Message MEM1208 MessageMEM8000 Message PCI1302 MessagePCI1360 Message PCI1320 MessagePCI1342 Message PCI1348 MessagePSU0002 Message PST0128 MessagePST0129 Message PSU0001 MessagePSU0032 Message PSU0006 MessagePSU0016 Message PSU0031 MessagePSU0037 Message PSU0034 MessagePSU0035 Message PSU0036 MessageSystem power consumption PSU1201 Message Power supply redundancy is lost DetailsSystem power inventory change Configuration and power consumptionRFM2002 Message RFM1014 MessageRFM1201 Message RFM2001 MessageSecurity may be compromised SEL0006 Message All event logging is disabled DetailsAppear if the user disabled event logging Power. If problem persists call supportTMP0121 Message Issues persists, contact supportFailed FailuresAlert Messages Diagnostic Messages144 Contacting Dell Getting Help
Related manuals
Manual 8 pages 28.21 Kb Manual 3 pages 53.88 Kb

E18S, E18S001, R420 specifications

The Dell E18S001, E18S, and R420 are notable products within Dell's extensive portfolio, catering to diverse computing needs, ranging from high-performance business applications to gaming and creative workloads.

The Dell E18S001 is designed with portability in mind, making it an ideal choice for professionals who need to work on-the-go. It boasts a sleek design with a lightweight frame, making it easy to transport. Powered by the latest Intel processors, the E18S001 offers exceptional performance for multitasking and running resource-intensive applications. With a vibrant display, users enjoy sharp graphics and vivid colors, perfect for graphic design or media consumption. Furthermore, it supports ample RAM and storage options, ensuring users can store important files and run multiple applications smoothly.

The E18S model focuses on delivering a balanced performance, supporting both business and everyday tasks. It features a durable build that can withstand daily wear and tear, making it suitable for office environments. This model is equipped with advanced connectivity options, including USB-C and HDMI ports, enabling seamless integration with various peripherals. Enhanced security features, such as a fingerprint reader, ensure that sensitive information remains protected, making it an attractive choice for corporate users.

On the other hand, the Dell R420 is a powerful server designed for enterprise-level performance. It is compatible with the Intel Xeon processor family, which is known for its reliability and efficiency. The R420 supports a high capacity of memory and offers flexible storage configurations to meet the demands of virtualized workloads and data-intensive applications. It also incorporates advanced management tools, allowing IT administrators to monitor and manage the system effectively. With its energy-efficient design, the R420 helps reduce operational costs while maintaining powerful performance.

Across these products, Dell emphasizes reliability, innovation, and user-friendly features. Each model comes equipped with state-of-the-art thermal management systems to ensure optimal performance and longevity. Additionally, Dell’s commitment to customer service and extensive warranty options further enhance the value of their products. From dynamic workstation needs to robust server requirements, the Dell E18S001, E18S, and R420 stand out as versatile solutions for a range of users.