Dell MD3660I manual For Suse Linux Enterprise Server SP3 Using The GUI, Go to Connected Targets

Page 41

3.If you are using Mutual CHAP authentication, you can set the user name and password for CHAP authentication of the target(s) by the initiator by editing the following lines:

node.session.auth.username_in=<iscsi_target_username> node.session.auth.password_in =<CHAP_target_password>

4.To set up discovery session CHAP authentication, first uncomment the following line: discovery.sendtargets.auth.authmethod = CHAP

5.Set a user name and password for a discovery session CHAP authentication of the initiator by the target(s) by editing the following lines:

discovery.sendtargets.auth.username =<iscsi_initiator_username> discovery.sendtargets.auth.password =<CHAP_initiator_password>

6.To set the user name and password for discovery session CHAP authentication of the target(s) by the initiator for Mutual CHAP, edit the following lines:

discovery.sendtargets.auth.username = <iscsi_target_username> discovery.sendtargets.auth.password_in = <CHAP_target_password>

7.The final configuration contained in the /etc/iscsi/iscsid.conf file may look like this:

node.session.auth.authmethod = CHAP

node.session.auth.username = iqn.2005- 03.com.redhat01.78b1b8cad821 node.session.auth.password = password_1 node.session.auth.username_in= iqn.1984- 05.com.dell:powervault.123456 node.session.auth.password_in = test1234567890 discovery.sendtargets.auth.authmethod = CHAP discovery.sendtargets.auth.username = iqn.2005- 03.com.redhat01.78b1b8cad821 discovery.sendtargets.auth.password = password_1

discovery.sendtargets.auth.username = iqn.1984- 05.com.dell:powervault. 123456discovery.sendtargets.auth.password_in = test1234567890

For SUSE Linux Enterprise Server SP3 Using The GUI

1.Click DesktopYaSTiSCSI Initiator.

2.Click Service Start, then select When Booting.

3.Select Discovered Targets, then select Discovery.

4.Enter the IP address of the port.

5.Click Next.

6.Select any target that is not logged in and click Log in.

7.Select one of the following:

If you are not using CHAP authentication, select No Authentication. Go to step 8. or

If you are using CHAP authentication, enter the CHAP user name and password. To enable Mutual CHAP, select and enter the Mutual CHAP user name and password.

8.Repeat step 7 for each target until at least one connection is logged in for each controller.

9.Go to Connected Targets.

10.Verify that the targets are connected and the status is true.

41

Image 41
Contents Page Dell Inc Contents Appendix Manual Configuration Of iSCSI Uninstalling MD Storage ManagerIncreasing Bandwidth With Multiple iSCSI Sessions Page System Requirements IntroductionIntroduction To Storage Arrays Management Station RequirementsPage Planning The Storage Configuration Hardware InstallationConnecting The Storage Array Cabling The Storage ArrayDirect-Attached Configurations Redundant And Non-Redundant ConfigurationsFour Hosts in a Dual-Controller Configuration Two Hosts Connected to Two Controllers Two Cluster Nodes Connected to Two Controllers Network-Attached Configurations Servers Connected to Two Controllers Servers Connected to Two RAID Controllers Cabling PowerVault MD3060e Expansion Enclosures Select Upgrade → EMM Firmware Expanding With New PowerVault MD3060e Expansion EnclosuresModular Disk Configuration Utility Installing MD Storage ManagerSelect Install MD Storage Software Graphical Installation RecommendedConsole Installation Enabling Premium Features Optional Silent InstallationUpgrading PowerVault MD Storage Manager Silent Installation On WindowsPage Before You Begin Post Installation TasksISCSI Configuration Terminology Configuring iSCSI On Your Storage Array ISCSI Configuration WorksheetStorage Array Configuration Post Connection Establishment Steps Configure The Storage Array Using PowerVault MdcuMicrosoft Windows Host Setup Guidelines For Configuring Your Network For iSCSIUsing a Dhcp server Using a Static IP AddressUsing a DNS Server Linux Host SetupUsing a Wins Server Using DhcpNETWORKING=yes HOSTNAME=mymachine.mycompany.com Page Uninstalling MD Storage Manager From Windows Uninstalling MD Storage ManagerRun the file Uninstall Dell MD Storage Software.exe Uninstalling MD Storage Manager From LinuxDiscover The Storage Array Out-of-band Management Only Appendix Manual Configuration Of iSCSIDefault Management Port Settings Automatic Storage Array Discovery Setting Up The ArrayManual Storage Array Discovery Launch MD Storage ManagerFor Windows Server 2003 Or Windows Server 2008 GUI Version Configure The iSCSI Ports On The Storage ArrayPerform Target Discovery From The iSCSI Initiator For Windows Server 2008 Core Version Understanding Chap Authentication Configure Host AccessWhat Is Chap Target ChapConfiguring Target Chap Authentication On The Storage Array Configure Chap Authentication On The Storage Array OptionalMutual Chap Chap DefinitionsConfiguring Mutual Chap Authentication On The Storage Array Configure Chap Authentication On The Host Server OptionalChap Setting Description Authentication before allowing accessIscsicli RemoveTargetPortal IPaddress TCPlisteningport Go to Connected Targets For Suse Linux Enterprise Server SP3 Using The GUIConnect To The Target Storage Array From The Host Server If you are using Windows Server 2008 Core VersionTCPPortNumberOfTargetPortal is For Linux ServerOptional Set Up In-Band Management Appendix Using Internet Storage Naming Service Page Windows Load Balance Policy Appendix Load BalancingRound Robin With Subset Least Queue Depth With SubsetIncreasing Bandwidth With Multiple iSCSI Sessions Initiator Configuration Page Appendix Stopping And Starting iSCSI Services In Linux Page Subnet Default gateway IPv4 Settings WorksheetISCSI port 1, ISCSI controller 0, IPv6 Settings WorksheetHost iSCSI port ISCSI controller 1,