Dell MD3660I manual Network-Attached Configurations

Page 14

Network-Attached Configurations

You can also cable the host servers to the RAID controller module iSCSI ports through industry-standard 10 Gbps or 1 Gbps Ethernet switches. An iSCSI configuration that uses Ethernet switches is frequently referred to as an IP SAN. By using an IP SAN, the PowerVault MD3660i series storage array can support up to 64 hosts simultaneously. This configuration supports either single or dual path data configurations and either single or dual controller modules.

The following figure shows up to 64 stand-alone servers attached (using multiple sessions) to a dual RAID controller module configuration through a network. Hosts that have a second Ethernet connection to the network allow two separate physical paths for each host, which ensures full redundancy if one of the paths fails. It is recommended you use two switches for more redundancy. However, single switch configuration is also supported.

14

Image 14
Contents Page Dell Inc Contents Uninstalling MD Storage Manager Appendix Manual Configuration Of iSCSIIncreasing Bandwidth With Multiple iSCSI Sessions Page Introduction To Storage Arrays IntroductionSystem Requirements Management Station RequirementsPage Connecting The Storage Array Hardware InstallationPlanning The Storage Configuration Cabling The Storage ArrayRedundant And Non-Redundant Configurations Direct-Attached ConfigurationsFour Hosts in a Dual-Controller Configuration Two Hosts Connected to Two Controllers Two Cluster Nodes Connected to Two Controllers Network-Attached Configurations Servers Connected to Two Controllers Servers Connected to Two RAID Controllers Cabling PowerVault MD3060e Expansion Enclosures Expanding With New PowerVault MD3060e Expansion Enclosures Select Upgrade → EMM FirmwareInstalling MD Storage Manager Modular Disk Configuration UtilitySelect Install MD Storage Software Graphical Installation RecommendedConsole Installation Upgrading PowerVault MD Storage Manager Silent InstallationEnabling Premium Features Optional Silent Installation On WindowsPage Before You Begin Post Installation TasksISCSI Configuration Terminology ISCSI Configuration Worksheet Configuring iSCSI On Your Storage ArrayStorage Array Configuration Configure The Storage Array Using PowerVault Mdcu Post Connection Establishment StepsUsing a Dhcp server Guidelines For Configuring Your Network For iSCSIMicrosoft Windows Host Setup Using a Static IP AddressUsing a Wins Server Linux Host SetupUsing a DNS Server Using DhcpNETWORKING=yes HOSTNAME=mymachine.mycompany.com Page Uninstalling MD Storage Manager Uninstalling MD Storage Manager From WindowsUninstalling MD Storage Manager From Linux Run the file Uninstall Dell MD Storage Software.exeDiscover The Storage Array Out-of-band Management Only Appendix Manual Configuration Of iSCSIDefault Management Port Settings Manual Storage Array Discovery Setting Up The ArrayAutomatic Storage Array Discovery Launch MD Storage ManagerFor Windows Server 2003 Or Windows Server 2008 GUI Version Configure The iSCSI Ports On The Storage ArrayPerform Target Discovery From The iSCSI Initiator For Windows Server 2008 Core Version What Is Chap Configure Host AccessUnderstanding Chap Authentication Target ChapMutual Chap Configure Chap Authentication On The Storage Array OptionalConfiguring Target Chap Authentication On The Storage Array Chap DefinitionsChap Setting Description Configure Chap Authentication On The Host Server OptionalConfiguring Mutual Chap Authentication On The Storage Array Authentication before allowing accessIscsicli RemoveTargetPortal IPaddress TCPlisteningport For Suse Linux Enterprise Server SP3 Using The GUI Go to Connected TargetsIf you are using Windows Server 2008 Core Version Connect To The Target Storage Array From The Host ServerFor Linux Server TCPPortNumberOfTargetPortal isOptional Set Up In-Band Management Appendix Using Internet Storage Naming Service Page Round Robin With Subset Appendix Load BalancingWindows Load Balance Policy Least Queue Depth With SubsetIncreasing Bandwidth With Multiple iSCSI Sessions Initiator Configuration Page Appendix Stopping And Starting iSCSI Services In Linux Page IPv4 Settings Worksheet Subnet Default gatewayISCSI port 1, ISCSI controller 0, IPv6 Settings WorksheetHost iSCSI port ISCSI controller 1,