Dell MD3660I manual

Page 22

22

Image 22
Contents Page Dell Inc Contents Uninstalling MD Storage Manager Appendix Manual Configuration Of iSCSIIncreasing Bandwidth With Multiple iSCSI Sessions Page Introduction To Storage Arrays IntroductionSystem Requirements Management Station RequirementsPage Connecting The Storage Array Hardware InstallationPlanning The Storage Configuration Cabling The Storage ArrayRedundant And Non-Redundant Configurations Direct-Attached ConfigurationsFour Hosts in a Dual-Controller Configuration Two Hosts Connected to Two Controllers Two Cluster Nodes Connected to Two Controllers Network-Attached Configurations Servers Connected to Two Controllers Servers Connected to Two RAID Controllers Cabling PowerVault MD3060e Expansion Enclosures Expanding With New PowerVault MD3060e Expansion Enclosures Select Upgrade → EMM Firmware Installing MD Storage Manager Modular Disk Configuration UtilityConsole Installation Graphical Installation RecommendedSelect Install MD Storage Software Upgrading PowerVault MD Storage Manager Silent InstallationEnabling Premium Features Optional Silent Installation On WindowsPage ISCSI Configuration Terminology Post Installation TasksBefore You Begin ISCSI Configuration Worksheet Configuring iSCSI On Your Storage ArrayStorage Array Configuration Configure The Storage Array Using PowerVault Mdcu Post Connection Establishment StepsUsing a Dhcp server Guidelines For Configuring Your Network For iSCSIMicrosoft Windows Host Setup Using a Static IP AddressUsing a Wins Server Linux Host SetupUsing a DNS Server Using DhcpNETWORKING=yes HOSTNAME=mymachine.mycompany.com Page Uninstalling MD Storage Manager Uninstalling MD Storage Manager From WindowsUninstalling MD Storage Manager From Linux Run the file Uninstall Dell MD Storage Software.exeDefault Management Port Settings Appendix Manual Configuration Of iSCSIDiscover The Storage Array Out-of-band Management Only Manual Storage Array Discovery Setting Up The ArrayAutomatic Storage Array Discovery Launch MD Storage ManagerPerform Target Discovery From The iSCSI Initiator Configure The iSCSI Ports On The Storage ArrayFor Windows Server 2003 Or Windows Server 2008 GUI Version For Windows Server 2008 Core Version What Is Chap Configure Host AccessUnderstanding Chap Authentication Target ChapMutual Chap Configure Chap Authentication On The Storage Array OptionalConfiguring Target Chap Authentication On The Storage Array Chap DefinitionsChap Setting Description Configure Chap Authentication On The Host Server OptionalConfiguring Mutual Chap Authentication On The Storage Array Authentication before allowing accessIscsicli RemoveTargetPortal IPaddress TCPlisteningport For Suse Linux Enterprise Server SP3 Using The GUI Go to Connected TargetsIf you are using Windows Server 2008 Core Version Connect To The Target Storage Array From The Host ServerFor Linux Server TCPPortNumberOfTargetPortal isOptional Set Up In-Band Management Appendix Using Internet Storage Naming Service Page Round Robin With Subset Appendix Load BalancingWindows Load Balance Policy Least Queue Depth With SubsetIncreasing Bandwidth With Multiple iSCSI Sessions Initiator Configuration Page Appendix Stopping And Starting iSCSI Services In Linux Page IPv4 Settings Worksheet Subnet Default gatewayISCSI port 1, Host iSCSI port IPv6 Settings WorksheetISCSI controller 0, ISCSI controller 1,