Dell CX4 manual Troubleshooting

Page 55
• Each zone contains the correct initiator and the correct storage port(s).
Troubleshooting

Troubleshooting

This appendix provides troubleshooting information for your cluster configuration. Table A-1 describes general cluster problems you may encounter and the probable causes and solutions for each problem.

Table A-1. General Cluster Troubleshooting

Problem

Probable Cause

Corrective Action

 

 

 

The nodes cannot

The storage system is

Ensure that the cables are connected

access the storage

not cabled properly to

properly from the node to the storage

system, or the

the nodes or the

system. See "Cabling Your Cluster for

cluster software is

cabling between the

Public and Private Networks" on

not functioning

storage components is

page 17 for more information.

with the storage

incorrect.

 

system.

 

 

 

The length of the

Ensure that the fibre optic cables do

 

interface cables

not exceed 300 m (multimode) or 10

 

exceeds the maximum

km (single mode switch-to-switch

 

allowable length.

connections only).

 

One of the cables is

Replace the faulty cable.

 

faulty.

 

 

Access Control is not

Verify the following:

 

enabled correctly.

• All switched zones are configured

 

 

 

 

correctly.

 

 

• The Access Control software is

 

 

enabled on the storage system.

 

 

• All LUNs and hosts are assigned to

 

 

the proper storage groups.

 

The cluster is in a

Verify the following:

 

SAN, and one or more

• Each zone contains only one initiator

 

zones are not

(Fibre Channel daughter card).

 

configured correctly.

 

 

55

Image 55
Contents Hardware Installation Troubleshooting Guide October Contents Installing the Fibre Channel HBAs Cluster Configuration OverviewImplementing Zoning on a Fibre Channel Zoning Configuration Form Contents Introduction IntroductionCluster Hardware Requirements Cluster SolutionCluster nodes Cluster storage For the internal drives Cluster NodesCluster Node Requirements Component Minimum Requirement IdenticalEnclosure Expansion Cluster StorageCluster Storage Requirements RequirementNavisphere Manager Storage Views Description EMC PowerPath Limitations in a Direct-Attached Cluster Supported Cluster ConfigurationsDirect-Attached Cluster SAN-Attached Cluster Other Documents You May NeedPage Cabling Your Cluster Hardware Cabling the Power SuppliesCabling Your Cluster Hardware Cabling the Mouse, Keyboard, and MonitorCabling Your Cluster Hardware Cabling Your Cluster for Public and Private Networks Network Connections Description Cabling the Public NetworkPrivate network Cluster node NIC Teaming Using Dual-Port Network AdaptersCabling the Storage Systems Cabling the Private NetworkFibre Channel Connections Cabling Storage for Your Direct-Attached ClusterCabling a Two-Node Cluster to a Dell/EMC Storage System Cabling a Cluster to a Dell/EMC Storage SystemCX4-120 or CX4-240 storage system Cluster node HBA portsCabling a Two-Node Cluster to a CX4-960 Storage System Cabling Your Cluster Hardware Cabling Two Two-Node Clusters to a Dell/EMC Storage System Cabling Storage for Your SAN-Attached ClusterStorage system Cabling Your Cluster Hardware Cluster node Private networkStorage system Cabling Your Cluster Hardware Cabling a SAN-Attached Cluster to a Dell/EMC Storage System Connect cluster node 1 to the SAN Sw0 CX4-480 storage system Sw1 Cabling Your Cluster Hardware 12. Cabling a SAN-Attached Cluster to the Dell\EMC CX4-960 CX4-960 storage systemFirst cluster, connect cluster node 1 to the SAN There is a maximum of four storage systems per cluster Connecting a PowerEdge Cluster to Multiple Storage SystemsStorage systems Connecting a PowerEdge Cluster to a Tape LibraryObtaining More Information Configuring Your Cluster With SAN BackupTape library Tape library Storage systems Cabling Your Cluster Hardware 15. Cluster Configuration Using SAN-Based BackupCabling Your Cluster Hardware Preparing Your Systems for Clustering Cluster Configuration OverviewPreparing Your Systems for Clustering Preparing Your Systems for Clustering Installation Overview Implementing Zoning on a Fibre Channel Switched Fabric Installing the Fibre Channel HBAsInstalling the Fibre Channel HBA Drivers Port Worldwide Names in a SAN Environment Using Worldwide Port Name ZoningPort Worldwide Names in a SAN Environment Identifier Single Initiator ZoningAccess Control Installing and Configuring the Shared Storage SystemStorage Groups IP address IP address of the host system Displays whether the path is enabled or disabledStorage Group Properties Property Description Name Name of the host systemNavisphere Agent Navisphere ManagerEMC PowerPath Preparing Your Systems for Clustering Configuring and Managing LUNs Configuring the Hard Drives on the Shared Storage SystemsConfiguring the RAID Level for the Shared Storage Subsystem SAN Copy Optional Storage FeaturesMirrorView SnapViewUpdating a Dell/EMC Storage System for Clustering Installing and Configuring a Failover ClusterPreparing Your Systems for Clustering Troubleshooting Troubleshooting Been booted Troubleshooting Use the Advanced with Check all zone configurationsCheck all cable connections Attached storage systemsMy Computer and click Manage Window, double-click ServicesCluster Services Recovery tabNode HBA WWPNs Storage Or Alias WWPNs or Names Zoning Configuration FormZoning Configuration Form Public IP Address Private IP Address Cluster Data Form Cluster Data FormName Seed Cluster Data Form DAEsIndex IndexInstalling SAN Index