B&B Electronics Multi-Interface Ethernet Serial Servers Console Mode, Upgrade Mode, RS-232 Mode

Page 11
Console Mode

Making Hardware Connections

Default Mode

When Default Mode is selected and the server properties are Updated (Saved) all the configuration settings return to their default values.

Note:

Refer to Chapter 5 for details on Serial Server Configuration settings.

See Chapter 12 for Serial Server default parameters.

Console Mode

In Console Mode the Configuration Menu can be accessed from a PC by connecting its RS-232 serial port to the ESP901 serial port or ESP902 Serial Port 1. Since the computer is a DTE device, and the serial ports are configured as DTEs (with DB-9M connectors), a null modem crossover cable must be used.

In Console Mode the default serial port settings are: 9600 baud, 8 data bits, No parity, and 1 stop bit. From Windows, HyperTerminal with VT100 terminal emulation can be used for

configuration.

Note:

Refer to Chapter 9 for details on Console Mode

Upgrade Mode

In Upgrade Mode firmware can be uploaded from a PC via its serial port to the ESP901 serial port or ESP902 Serial Port 1. Upgrading also can be accomplished via the network connection, using the ESP Manager software and a virtual COM port.

Note:

Refer to Chapter 8 for details on Upgrade Mode

RS-232 Mode

In RS-232 Mode the currently selected serial port is configured as an RS-232 interface supporting eight RS-232 signal lines plus Signal Ground and is configured as a DTE, like a computer. Signals are single ended and referenced to Ground. To use handshaking, Flow Control must be set to RTS/CTS during Configuration.

Note:

Refer to Appendix A for RS-232 connection pin-outs.

Manual Documentation Number: ESP901-902_4105m

Chapter 2

13

Making Hardware Connections

RS-422 Mode

In RS-422 Mode the currently selected serial port is configured as an RS-422 interface supporting four RS-422 signal channels with full duplex operation for Receive, Transmit, RTS (Request To Send) and CTS (Clear To Send). The data lines are differential pairs (A & B) in which the B line is positive relative to the A line in the idle (mark) state. Ground provides a common mode reference. To use handshaking, Flow Control must be set to RTS/CTS during configuration.

Note:

Refer to Appendix B RS-422 connection pin-outs.

RS-485 Mode

In RS-485 Mode the currently selected port is configured as an RS-485 interface supporting transmit (TX) and receive (RX) signal channels using 2-wire, half-duplex operation. The data lines are differential with the Data B line positive relative to Data A in the idle (mark) state. Ground provides a common mode reference.

Note:

Refer to Appendix C for RS-485 connection pin-outs.

RS-485 Receiver Biasing

RS-485 Receiver Biasing can be implemented from the Serial Server if the network does not supply it. Remove the two side-cover screws of the Serial Server, slide the cover off and re-position the bias jumpers (shown open in the figure below) to enable biasing (shorting).

Figure 10. Internal Setting to Select RS-485 Bias

Note:

(For more information on RS-485 Receiver Biasing, see B&B Electronics RS-422/485 Application Note available at www.bb- elec.com)

14

Chapter 2

Manual Documentation Number: ESP901-902_4105m

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

www.bb-elec.com

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104

www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

www.bb-europe.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445

www.bb-europe.com

Image 11 Contents
Multi-Interface Ethernet Serial Servers Manual Documentation Number ESP901-9024105m Table of Contents Using Console Mode Introduction FeaturesCommunication Modes Direct IP ModeVirtual COM Mode Paired ModeSerial Server Quick Start Guide Hardware SetupSoftware Installation Serial Server ConfigurationCheck Communications Install Virtual COM Ports on PCMaking the Hardware Connections Package ChecklistESP901/ESP902 Connections, Indicators and Reset Switch Serial Ports DIP SwitchesSerial Server/Port Operational Modes RS-422 Mode Console ModeUpgrade Mode RS-232 ModeDTE Serial Server Serial Port Connector Pin-outsManual Installation Installing the Vlinx ESP SoftwareSoftware Installation Automatic InstallationOpening the ESP Manager Updating an Existing InstallationSoftware Setup Using ESP ManagerHardware Setup Menus Software OverviewStatus Bar Search for ServersServer Icons Pane Serial Server / Virtual COM ListsSearch Vlinx ESP Dialogue Box Configure Server PropertiesRestarting Dialogue Box Server Name Configuring the Serial Server PropertiesPassword Description of the Server PropertiesMAC Address IP AddressNetmask GatewayFlow Control Serial TimeoutTCP Alive Timeout Connection ModeTCP/UDP Port Serial Port ModeUpdate/Save Port StatusFollowing dialogue box will appear Web Server Virtual COM Port Installation Installing Virtual COM PortsWindows Logo Testing Window Matching the Serial Server and Virtual COM Port SettingsVlinx ESP COM3 Properties Window Removing the Virtual COM port with ESP Manager Removing the Virtual COM Port using Device ManagerRemoving Virtual COM Ports Control Panel Window Preparing the Software Upgrading the Serial Server FirmwareDownloading the Firmware Upgrading Via ESP ManagerNavigating the Configuration Menus Using Console ModeConsole Mode Setup Saving and Restarting the Configuration Using a PasswordSetting Server Properties Using the WEB ServerWeb Server Operation Navigating the Configuration Menu Using TelnetConfiguration Using Telnet Telnet Configuration Screens ESP901 and ESP902 Technical DataDhcp RS-232 Crossover null modem Cable Connections Serial Server DB-9 Pin-outs in RS-232 ModeRS-232 Straight-through Cable Connections RS-232 DTE Loopback Connections RS-232 Crossover DB-9 to DB-25 Conversion ConnectionsAppendix B RS-422 Connections Serial Server DB-9 Pin-outs in RS-422 ModeLoopback Connections for RS-422 Appendix C RS-485 Connections Serial Server DB-9 Pin-out in RS-485 ModeCrossover Ethernet Cable RJ-45 Pin-out Standard Ethernet Cable RJ-45 Pin-outElectronics October
Related manuals
Manual 61 pages 14.7 Kb Manual 46 pages 1.37 Kb Manual 39 pages 36.61 Kb