B&B Electronics ESP904E manual Installing the Vlinx ESP Software, Software Installation

Page 15

Installing the VLINX ESP Software

Chapter 3: INSTALLING THE VLINX ESP SOFTWARE

The Windows-based ESP Manager and Virtual COM Port software makes configuration fast and easy. If using Windows, installing the ESP Manager software and setting up virtual COM ports to configure the ESP904 is recommended.

Software Installation

The VLINX ESP software includes:

ESP Manager

Install Virtual COM Ports

Uninstall Virtual COM Ports

Automatic Installation

Step 1a: Inserting the VLINX CD in the CD-ROM should automatically launch the Install Shield Wizard.

Manual Installation

Step 1b: To manually start the software installation, select the Start button on the desktop. At the Run command line type D:start.exe. Then select OK. The D: is the drive letter for the CD Rom.

Figure 12. The Run Dialogue Box

The Install Shield Wizard window will be displayed.

Installing the VLINX ESP Software

Figure 13. The Install Shield Wizard Window

Step 2: When the VLINX ESP Setup window appears, click Next.

Figure 14. VLINX ESP Setup Window

Figure 15. The Choose Destination Window

Step 3: When Choose Destination Location appears, Click Next.

The installation progress will be shown until complete.

Manual Documentation Number: ESP904-0504

Chapter 3

19

20

Chapter 3

Manual Documentation Number: ESP904-0504

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.com

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

Image 15
Contents RS-232/422/485 Quad-Port Multi-Interface Ethernet Serial ServerInternational Headquarters Table of Contents Using Console Mode Table of Figures DB-9 Pin-out in RS-485 Mode Wire RS-485 ConnectionIntroduction FeaturesDirect IP Mode Virtual COM ModeESP904 Quick Start Guide Paired ModeHardware Setup Software InstallationWhen the parameters have been set, click on Update ESP904 ConfigurationESP904 Technical Data Install Virtual COM Ports on PCCheck Communications Settings Serial Number Configuration Console ModeOptions Telnet Mode Default Server Server NameEthernet Connector Package ChecklistESP904 Connections, Indicators and Reset Switch Indicator LightsSerial Port Operational Modes RS-232 Mode RS-422 ModeRS-485 Mode ESP904 Serial Port Connector Pin-outs DB-9M RS-232RS-422 RS-485 Manual Installation Installing the Vlinx ESP SoftwareSoftware Installation Automatic InstallationInstall Shield Wizard Complete Window Using ESP Manager Hardware SetupSoftware Setup Serial Server List Server Icons SectionSearching Server Virtual COM ListServer Properties Screen Vcomui Window Configuring the ESP904 Server PropertiesDescription of the Server Properties Baud Rate Connection ModeTimeout Server Serial Port Select 1 toUpdate/Save Virtual COM Port Installation Installing Virtual COM PortsWindows Logo Testing Window Matching the ESP904 and Virtual COM Port SettingsVlinx ESP COM3 Properties Window Removing the Virtual COM Port using Device Manager Removing Virtual COM PortsRemoving the Virtual COM port with ESP904 Manager Control Panel Window Upgrading Via ESP904 Manager Upgrading the ESP904Firmware Downloading the FirmwareUpgrading in Progress Using Console Mode Console Mode SetupNavigating the Configuration Menu Saving and Restarting the Configuration Using a PasswordSetting Server Properties Using the WEB ServerRS-232 Crossover null modem Cable Connections ESP904 DB-9 Pin-outs in RS-232 ModeAppendix a RS-232 Connections RS-232 Straight-through Cable ConnectionsRS-232 DTE Loopback Connections RS-232 Crossover DB-9 to DB-25 Conversion ConnectionsAppendix B RS-422 Connections ESP904 DB-9 Pin-outs in RS-422 ModeLoopback Connections for RS-422 Pin ESP904 DB-9 Pin-out in RS-485 ModeAppendix C RS-485 Connections RS-485 DirectionCrossover Ethernet Cable RJ-45 Pin-out RJ-45 Pin Signal Wire ColorAppendix D Network Connections Standard Ethernet Cable RJ-45 Pin-out

ESP904E, ESP904 specifications

B&B Electronics has established itself as a leader in developing innovative communication and networking solutions, and the ESP904 and ESP904E models are perfect examples of this commitment to excellence. These devices are designed specifically for Serial to Ethernet/IP communication, making them suitable for a wide range of applications in industrial environments.

One of the main features of the ESP904 is its ability to convert serial data from RS-232, RS-422, or RS-485 interfaces into Ethernet data, facilitating communication with remote servers or other devices over an IP network. This serial-to-Ethernet conversion enables the integration of legacy serial devices into modern network infrastructures, ensuring that businesses can take advantage of new technologies while maximizing their existing investments.

The ESP904E model enhances the base ESP904 by adding even more advanced features, including increased processing power and enhanced security protocols. This robustness is crucial for applications where data integrity and security are paramount, such as in industrial automation, transportation, and telecommunications. The device supports a wide range of encryption methods for secure communications, protecting sensitive data from unauthorized access.

In terms of technologies, both models support full TCP/IP networking capabilities, allowing for seamless communication across various network environments. They are equipped with a built-in web server, enabling easy configuration and monitoring via a standard web browser. This eliminates the need for dedicated software and simplifies the deployment process.

Key characteristics of the ESP904 and ESP904E include robust construction designed for harsh industrial conditions, a compact design that allows for easy installation, and the ability to support multiple simultaneous connections. They also feature flexible power options, enabling connections through PoE (Power over Ethernet) or traditional power supplies, enhancing compatibility with different setups.

In addition, both models support various operating modes, including Server, Client, and Proxy modes, giving users flexibility in how they integrate their devices. The modular design of the ESP904 and ESP904E means that they can be easily updated and expanded as technology evolves.

Overall, the B&B Electronics ESP904 and ESP904E are powerful tools for organizations looking to modernize their communication architectures, providing reliability and performance that meet the demands of today’s networking environments. Whether for a small setup or a complex industrial network, these devices offer the versatility and capabilities needed to ensure success.