B&B Electronics Comprehensive Guide to VLINX ESP Manager for Server Configuration

Page 18

Using ESP Manager

The following window should appear:

Figure 19. The VLINX ESP Manager Window

The VLINX ESP Manager window is divided into two sections:

The left (Server Icons) section displays icons used to run:

Firmware Upgrade

Virtual COM Configuration

Searching Server

Uninstall Virtual COM

The right section (Configuration Lists) contains two windows (selectable by tabs at the bottom of the window). These windows are the Serial Server List and the Virtual COM List.

The Serial Server List contains the following information:

Server Name

IP Address

Protocol

Port

COM Name

Status

Manual Documentation Number: ESP904-0504

Chapter 4

25

Using ESP Manager

The Virtual COM List contains the following information:

COM Name

IP Address

Protocol

Port

Flow Control

Status

Server Icons Section

Firmware Upgrade

Used when downloading new firmware to the ESP Server.

Note:

See Chapter 8 for more information on upgrading firmware.

Virtual COM Configuration

Selects the Virtual COM List. Double clicking on any COM port in the Virtual COM List brings up a window that allows changing the virtual COM settings such as Flow Control, Protocol, IP address, and Port Number. Virtual COM settings must match ESP904 port settings.

Searching Server

Searches for ESP Servers on the network and brings back configuration information that will be displayed in the Server Properties window.

Uninstall Virtual COM

Allows virtual COM ports to be uninstalled from the ESP Manager window.

Serial Server List

Server Name

Displays the name of the ESP904 Server. The name is listed four times, once for each port.

IP Address

Displays the IP Address for the ESP904 server. All four ports have the same the same IP address.

26

Chapter 4

Manual Documentation Number: ESP904-0504

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.com

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445www.bb-europe.com

Image 18
Contents Quad-Port Multi-Interface Ethernet Serial Server RS-232/422/485International Headquarters Table of Contents Using Console Mode DB-9 Pin-out in RS-485 Mode Wire RS-485 Connection Table of FiguresVirtual COM Mode FeaturesDirect IP Mode IntroductionSoftware Installation Paired ModeHardware Setup ESP904 Quick Start GuideESP904 Configuration When the parameters have been set, click on UpdateESP904 Technical Data Install Virtual COM Ports on PCCheck Communications Default Server Server Name Configuration Console ModeOptions Telnet Mode Settings Serial NumberIndicator Lights Package ChecklistESP904 Connections, Indicators and Reset Switch Ethernet ConnectorSerial Port Operational Modes RS-232 Mode RS-422 ModeRS-485 Mode ESP904 Serial Port Connector Pin-outs DB-9M RS-232RS-422 RS-485 Automatic Installation Installing the Vlinx ESP SoftwareSoftware Installation Manual InstallationInstall Shield Wizard Complete Window Using ESP Manager Hardware SetupSoftware Setup Server Icons Section Serial Server ListSearching Server Virtual COM ListServer Properties Screen Vcomui Window Configuring the ESP904 Server PropertiesDescription of the Server Properties Server Serial Port Select 1 to Connection ModeTimeout Baud RateUpdate/Save Installing Virtual COM Ports Virtual COM Port InstallationMatching the ESP904 and Virtual COM Port Settings Windows Logo Testing WindowVlinx ESP COM3 Properties Window Removing the Virtual COM Port using Device Manager Removing Virtual COM PortsRemoving the Virtual COM port with ESP904 Manager Control Panel Window Downloading the Firmware Upgrading the ESP904Firmware Upgrading Via ESP904 ManagerUpgrading in Progress Using Console Mode Console Mode SetupNavigating the Configuration Menu Using a Password Saving and Restarting the ConfigurationUsing the WEB Server Setting Server PropertiesRS-232 Straight-through Cable Connections ESP904 DB-9 Pin-outs in RS-232 ModeAppendix a RS-232 Connections RS-232 Crossover null modem Cable ConnectionsRS-232 Crossover DB-9 to DB-25 Conversion Connections RS-232 DTE Loopback ConnectionsESP904 DB-9 Pin-outs in RS-422 Mode Appendix B RS-422 ConnectionsLoopback Connections for RS-422 RS-485 Direction ESP904 DB-9 Pin-out in RS-485 ModeAppendix C RS-485 Connections PinStandard Ethernet Cable RJ-45 Pin-out RJ-45 Pin Signal Wire ColorAppendix D Network Connections Crossover Ethernet Cable RJ-45 Pin-out

ESP904E, ESP904 specifications

B&B Electronics has established itself as a leader in developing innovative communication and networking solutions, and the ESP904 and ESP904E models are perfect examples of this commitment to excellence. These devices are designed specifically for Serial to Ethernet/IP communication, making them suitable for a wide range of applications in industrial environments.

One of the main features of the ESP904 is its ability to convert serial data from RS-232, RS-422, or RS-485 interfaces into Ethernet data, facilitating communication with remote servers or other devices over an IP network. This serial-to-Ethernet conversion enables the integration of legacy serial devices into modern network infrastructures, ensuring that businesses can take advantage of new technologies while maximizing their existing investments.

The ESP904E model enhances the base ESP904 by adding even more advanced features, including increased processing power and enhanced security protocols. This robustness is crucial for applications where data integrity and security are paramount, such as in industrial automation, transportation, and telecommunications. The device supports a wide range of encryption methods for secure communications, protecting sensitive data from unauthorized access.

In terms of technologies, both models support full TCP/IP networking capabilities, allowing for seamless communication across various network environments. They are equipped with a built-in web server, enabling easy configuration and monitoring via a standard web browser. This eliminates the need for dedicated software and simplifies the deployment process.

Key characteristics of the ESP904 and ESP904E include robust construction designed for harsh industrial conditions, a compact design that allows for easy installation, and the ability to support multiple simultaneous connections. They also feature flexible power options, enabling connections through PoE (Power over Ethernet) or traditional power supplies, enhancing compatibility with different setups.

In addition, both models support various operating modes, including Server, Client, and Proxy modes, giving users flexibility in how they integrate their devices. The modular design of the ESP904 and ESP904E means that they can be easily updated and expanded as technology evolves.

Overall, the B&B Electronics ESP904 and ESP904E are powerful tools for organizations looking to modernize their communication architectures, providing reliability and performance that meet the demands of today’s networking environments. Whether for a small setup or a complex industrial network, these devices offer the versatility and capabilities needed to ensure success.