Promise Technology VTrak external disk array subsystem, m210p manual Enclosures, Identify Enclosure

Page 89

Chapter 4: Management with WebPAM PROe

10GB Truncate – Reduces the useful capacity to the nearest 10,000,000,000 byte boundary.

Group Rounding – Uses an algorithm to determine how much to truncate. Results in the maximum amount of usable drive capacity.

Table Rounding – Applies a predefined table to determine how much to truncate.

10.Enter a time interval (1 to 12 seconds) in the Write Back Cache Flush Interval field.

For more information, see “Cache Policy” on page 192.

11.Select a Cache Line Size (8KB or 64KB) from the Preferred Cache Line Size dropdown menu.

For more information, see “Cache Line Size” on page 193.

12.Click the Submit button.

The changes take effect immediately.

Enclosures

The Enclosures–Information tab provides component information about the VTrak subsystem enclosure, including:

Enclosure ID number

Number of power supply units

Number of fans

Number of blowers – Blowers are scroll fans, one in each cooling unit

Number of physical drive slots – 12 or 8 depending on the VTrak model

Number of temperature sensors – The number of sensors varies among VTrak models

Number of voltage sensors – 3.3V, 5.0V, and 12.0V

Number of batteries – One for each controller in the enclosure

Identify Enclosure

To identify the VTrak subsystem enclosure:

1.Click the Subsystem icon in Tree View.

2.Click on the Enclosures icon.

3.Click on the Locate Enclosure button.

The FRU LEDs on the back of the enclosure will flash for one minute. See the illustration below.

81

Image 89
Contents Vtrak Trademarks CopyrightImportant data protection information RecommendationsContents Management with WebPAM PROe Management with the CLU Technology Background MaintenanceSupport TroubleshootingAppendix a Useful Information IndexVTrak M310p, M210p Product Manual Viii About This Manual IntroductionVTrak M310p front view M210p is similar OverviewArchitectural Description Features and BenefitsFeature Benefit Maximum performance in Multi-Threaded RAID SpecificationsFCC Statement Unpack the VTrak InstallationRackmounted VTrak M310p M210p is similar Mount VTrak in a RackInstallation Install Disk Drives VTrak M310p/M210p drive carrier mounting holes Drive Numbering NIC Connect Network and Data CablesSerial connector for VTrak M310p/M210p Set Up Serial Cable ConnectionsVTrak M310p/M210p front panel LED display Connect the PowerVTrak M310p, M210p Product Manual VTrak Setup with CLI or CLU SetupCLI Administrator@cli net -a mod -t mgmt -s dhcp=enableSystem Date and Time CLUManagement Port Exit the CLU Log-in to WebPAM PROe VTrak Setup with WebPAM PROeRegular Connection Secure ConnectionSetup VTrak M310p, M210p Product Manual Language Selection Automatic Create a Disk ArrayExpress VTrak M310p, M210p Product Manual Advanced VTrak M310p, M210p Product Manual Setup VTrak M310p, M210p Product Manual Setup VTrak M310p, M210p Product Manual Log-out of WebPAM PROe Internet Connection using WebPAM PROeAdditional Logical Drives VTrak M310p, M210p Product Manual Management with WebPAM PROe VTrak Status IndicatorsState LEDs Dark Steady Flashing Amber Red Green Audible Alarm Drive Status IndicatorsLEDs State Steady Flashing Amber Red GreenHttps//192.168.10.148 Log-in/Log-outHttp//192.168.10.148 Management with WebPAM PROe WebPAM PROe Opening Screen Graphic User Interface Function HeaderLanguage Selection ViewContact Us Storage NetworkTree View Event Frame SubsystemsManagement Window Subsystem Information Subsystem SettingsSubsystem View Events Subsystem EventsClear Events Save EventsStart Background Function Change Background SettingsBackground Activities Schedule an Activity SchedulerView Scheduled Activities Delete an Activity View Lock Status LockSet Lock Renew LockRelease Lock Administrative ToolsUser Information User Settings AdministratorUser Management User Event Subscription User Settings UserSmart List of User Notification EventsCreate a User User Password AdministratorUser Password Users List of User Privileges Delete a UserUser Sessions Network Management Scsi Channel Information Scsi Channel SettingsScsi Management View LUN Map Storage ServicesScsi Target Information LUN Mapping Parameters Software ManagementEdit a LUN Map Manual Start, Restart, Stop Change Email SettingSend a Test Message Web Server Click on the Web Server Setting linkTelnet Change Start SettingChange Start Setting Snmp CIM Netsend CIM Service SettingsAdd Recipients Delete Recipients ExportImport Firmware Update Clear Statistics Restore Factory DefaultsShutdown Shutdown and RestartMonitor the Shutdown Restart the SubsystemMonitor the Restart ControllersController Information ControllerController Statistics Clear Statistics Controller SettingsIdentify Enclosure EnclosuresEnclosure Information EnclosureFRU VPD Enclosure SettingsBattery Recondition BatterySilence Buzzer Change Buzzer SettingsBuzzer Identify a Physical Drive Physical Drives SettingsPhysical Drives Advanced Physical Drive Information Physical DrivePhysical Drive Information Identify a Physical Drive Physical Drive StatisticsClear Physical Drive Conditions Physical Drive SettingsForce a Physical Drive Offline/Online Physical Drive Media Patrol Disk ArraysCreate a Disk Array Express Create a Disk Array AutomaticManagement with WebPAM PROe Logical Drive Creation Create a Disk Array AdvancedDisk Array Creation Summary Delete a Disk ArrayDisk Array Information Disk ArrayDisk Array Status Physical Drives in the Disk ArrayLogical Drives in the Disk Array Create a Logical Drive Disk Array SettingsManagement with WebPAM PROe Disk Array Migration Delete a Logical DriveDisk Array Rebuild Manual Rebuild Disk Array Background ActivityView Progress of Background Function TransitionTransport Logical DrivesLogical Drive Status Logical Drive Information Logical DriveLogical Drive Statistics in alphabetical order Logical Drive SettingsLogical Drive Initialization Logical Drive Background ActivityLogical Drive Synchronization Logical Drive Redundancy CheckLogical Drive Check Table Logical Drive PDMLUN Mapping Parameters Logical Drive LUN SettingsSpare Drives Delete Spare Drive Create Spare DriveSpare Drive Information Spare Check All Spare DrivesSpare Drive Locate a Spare Drive Spare Drive SettingsSpare Check Individual Spare Drive Logical Drive Summary VTrak M310p, M210p Product Manual 118 Management with the CLU State LEDs Dark Steady Flashing Amber Red Green Audible Alarm Serial Connection CLU ConnectionTelnet Connection Telnet 192.168.1.56123 Exit the CLU CLU Function Map 126 127 128 129 130 131 Subsystem Management Quick SetupAlias Media PatrolController Management System Date and TimePhysical Drive Coercion Controller SettingsAlias Enclosure Management Power Supply UnitsEnclosure Status Enclosure ManagementTemperature Sensors Enclosure SettingsBlowers Voltage SensorsPolling Interval Temperature ThresholdsBatteries Physical Drive Management Global Physical Drive SettingsLocate Enclosure Write CacheIndividual Physical Drive Settings Locate Physical Drive Force Physical Drive Offline/OnlineDisk Array Management Highlight Save Settings and Continue and press Enter Delete a Disk Array Disk Array Information Disk Array Settings and FunctionsMedia Patrol RebuildPredictive Data Migration MigrationAccept Incomplete Array Locate Disk ArrayCreate a Logical Drive Delete a Logical Drive Logical Drive Management Logical Drive Settings and FunctionsLogical Drive Information Write Cache PolicyRedundancy Check InitializationNetwork Management Management Port SettingsLocate Logical Drive ManualChannel Information Channel SettingsScsi Management Target Information Background ActivityBackground Activities List Background Activity SettingsNvram Events Event ViewerRuntime Events Create New Spare Drive Additional Info and ManagementSpare Drive Management Delete Spare Drive LUN MappingCreate New User User Settings Privilege and Status PasswordUser Settings Display Name and Email Address Delete User Webserver 161 Snmp Trap Sinks Highlight Create New Message Recipient and press Enter Netsend RecipientsFlash through Tftp Restart over Telnet Shutdown over TelnetShutdown over Serial Restart over Serial BuzzerMaintenance Your PC Firmware Update WebPAM PROeTftp Server Restart VTrak Firmware Update CLU VTrak M310p/M210p power supply Replace Power SupplyReplace Cooling Unit Blower Electrical connector 174 Replace Cache Battery Remove this screw Maintenance Replace RAID Controller Introduction to RAID Technology BackgroundRAID 0 Striping interleaves data across multiple drives RAID 0 StripeData Mirror Disk Drives RAID 1 MirrorRAID 1E Enhanced Mirror RAID 5 Stripes all drives with data and parity information RAID 5 Block and Parity StripeRAID 6 Block and Double Parity Stripe RAID 10 Mirror + Stripe RAID 50 Axles RAID 50 Striping of Distributed ParityPer Axle No. of Drives No. of Axles RAIDArray Advantages Disadvantages Choosing a RAID LevelRAID 1E 190 Sector Size Stripe SizeRead Cache Policy Cache PolicyCache Line Size Capacity CoercionWrite Cache Policy Hot Spare Drives InitializationRAID Level Migration Partition and Format the Logical DrivePerformance From Increase Redundancy CapacityAdd Lose Ranges of Disk Array Expansion Create a New Logical Drive Media PatrolCurrent LD Size Maximum LD Sector Size Expansion Size PDM Triggers Predictive Data Migration PDMExample Transition201 Manual Transition Automatic TransitionVTrak is Beeping TroubleshootingFront Panel LEDs Display Amber or RedVTrak M310p/M200p disk carrier LEDs Drive Status IndicatorsBack of Enclosure Dark Green Amber Red Fan LED on a VTrak M310p/M210p cooling unitGreen Amber Flashing CLU Reports a ProblemPDM WebPAM PROe Reports a Problem 211 Event Action BatteryEvent Notification Response Battery reconditioning has Controller BlowersCache Drive Interface Controller Disk ArrayHost Interface Controller EnclosureEvent Log Logical Drive Media Patrol PDM Physical Disk Physical disk negotiation RAID Level Migration PSU FansRebuild Spare Check Redundancy CheckResource Stripe Level Migration Spare DrivesSynchronization SubsystemSystem VTrak TransitionWatermark With a Hot Spare Drive When a Disk Drive FailsCritical & Offline Disk Arrays Rebuild Operation Without a Hot Spare Drive230 Enclosure Problems Overheating Power Supplies Termination Connection ProblemsScsi Connections Network Connections Serial ConnectionsAmber Green Flashing Green Unsaved Data in the Controller CacheHow can I tell when the VTrak has fully booted? Frequently Asked QuestionsWhy does VTrak come with a Command Line Utility? What kind of disk drives can I use with VTrak?Are logical drives on VTrak limited to 2.199 terabytes? Can VTrak run using just one power supply? Technical Support ServicesContact Technical Support How can I be sure everything is working OK on the VTrak?Europe, Africa, Middle East United StatesGermany ItalyChina TaiwanDisclaimer of other warranties Limited WarrantyYour Responsibilities Returning Product For RepairOr retailer Pin Signal Serial Connector PinoutLoad MIB Files Snmp MIB FilesIndex 212 PROe 25 PDM 30, 110, 144 RAID 5 183 Create 113, 155 delete 113 253 VTrak M310p, M210p Product Manual 254
Related manuals
Manual 30 pages 35.94 Kb

m210p, VTrak external disk array subsystem, m310p specifications

Promise Technology has established itself as a strong player in the storage solutions market, particularly with its VTrak series of storage systems. Among the notable products in this lineup are the VTrak M310P and M210P models, designed to deliver efficiency, scalability, and high performance for businesses of all sizes.

The Promise VTrak M310P is a high-performance storage solution that emphasizes speed and versatility. This model supports both SAS and SATA drives, enabling enterprises to tailor their storage needs based on workload requirements. It is built with an advanced RAID engine that provides multiple RAID levels, including RAID 0, 1, 5, 6, 10, 50, and 60, ensuring data redundancy and protection against drive failures. The M310P can accommodate up to 96TB of raw storage when fully populated, catering to environments that require large amounts of data retention and quick access times.

Key features of the VTrak M310P include the intuitive management interface, which simplifies storage provisioning and monitoring. This model also incorporates Promise's innovative "HyperRAID" technology, which enhances performance by optimizing I/O operations and providing real-time analytics and reporting. Additionally, the M310P supports a variety of host connection interfaces, including iSCSI, Fibre Channel, and InfiniBand, allowing seamless integration into existing infrastructure.

On the other hand, the VTrak M210P is tailored for a slightly different audience, focusing on small to medium-sized businesses that require reliable and cost-effective storage solutions. The M210P retains several high-end features found in its bigger counterpart while offering a more budget-friendly option. This model also supports a mix of SAS and SATA drives and includes RAID capabilities similar to the M310P for data protection.

The M210P provides a robust set of management tools designed for ease of use, including automated alerts and comprehensive reporting capabilities. Its compact design and reliable performance make it ideal for remote office locations or data centers where space is a premium. Furthermore, the model incorporates advanced power management features to reduce energy consumption without compromising performance.

Both the M310P and M210P are built with scalability in mind, allowing businesses to easily expand their storage capacity as data needs grow. With a focus on durability, performance, and advanced technology, Promise Technology’s VTrak systems are well-positioned to meet the evolving demands of modern data storage. Whether for large enterprises or smaller organizations, these products offer solutions that enhance productivity and ensure data integrity.