Chapter 7: Technology Background
2.Delete the current logical drive.
See page 137 (WebPAM PROe) or page 188 (CLU).
3.Create a new logical drive with the desired capacity. See page 135 (WebPAM PROe) or page 187 (CLU).
4.Restore the data to the new logical drive.
Media Patrol
Media Patrol is a routine maintenance procedure that checks the magnetic media on each disk drive. Media Patrol checks all physical drives assigned to disk arrays. Media Patrol does not check unconfigured drives.
Media Patrol will also check spare drives, if those drives have Media Patrol enabled. Media Patrol for spare drives is enabled by default. You can disable it in VTrak’s Command Line Interface (CLI).
Unlike Synchronization and Redundancy Check, Media Patrol is concerned with the condition of the media itself, not the data recorded on the media. If Media Patrol encounters a critical error, it triggers PDM if PDM is enabled.
See “Physical Drive Media Patrol” on page 128.
Predictive Data Migration (PDM)
Predictive Data Migration (PDM) is the migration of data from the suspect disk drive to a spare disk drive, similar to Rebuilding a Logical Drive. But unlike Rebuilding, PDM constantly monitors your disk drives and automatically copies your data to a spare disk drive before the disk drive fails and your Logical Drive goes Critical.
After the data is copied from the suspect disk drive, the controller marks it with a Stale configuration and a PFA error.
You can clear the Stale configuration and PFA error and put the disk drive back into service. See “Clear Physical Drive Conditions” on page 126 for WebPAM PROe or see “Clear Stale and PFA Conditions” on page 180 for the CLU. In most cases, however, you will remove the disk drive for repair or replacement.
PDM Triggers
The following actions trigger PDM:
•A disk drive with unhealthy status (see below)
•Media Patrol finds a disk critical error*
•You initiate PDM manually
*PDM also counts the number of media errors reported by Media Patrol.
257