Silex technology PRICOM C-6400W manual TCP/IP parameter

Page 99

Users Manual CX2

- TCP/IP parameter

 

Topic

Explain

Factory Default

 

 

Enable/Disable DHCP/BOOTP protocol operations.

 

 

 

DHCP/BOOTP is a protocol, via which IP address gets

 

 

 

assigned by the BOOTP server or DHCP server. If you

 

DHCP/BOOTP

use

ENABLE

DHCP/BOOTP server, the DHCP/BOOTP server must

 

 

be in the same segment as the print server. This print

 

 

 

server detects DHCP and BOOTP automatically. If

 

 

 

more than 1 address get returned, the IP address

 

 

 

which is returned first will be used.

 

 

 

Enable/Disable RARP protocol operations. RARP is a

 

 

RARP

protocol, via which IP address gets assigned by the

ENABLE

 

RARP server. If you use RARP server, the RARP

 

 

server must be in the same segment as the print

 

 

 

server.

 

IP Address

Setting the Print Server IP address. The IP address

 

must be 4 numbers, each between 0-255 (eg.

0.0.0.0

 

 

192.168.100.10).

 

 

 

Setting the print server subnet mask. The subnet mask

 

SubnetMask

must be 4 numbers, each between 0-255 (eg.

0.0.0.0

255.255.255.0). However, entering 0.0.0.0 would not be

 

 

valid, and the subnet mask corresponding to the IP

 

 

 

address would be used automatically.

 

 

 

Setting the default gateway address. The default

 

Default Gateway

gateway address must be 4 numbers, each between 0-

 

255 (eg. 192.168.100.240). If you use a gateway, the

0.0.0.0

 

 

gateway must be in the same segment as the print

 

 

 

server. However, entering 0.0.0.0 would not be valid.

 

 

 

Setting the WINS server (primary) address. WINS

 

 

 

server will resolve the IP address from the host name.

0.0.0.0

 

Primary Server

Therefore you can use a hostname instead of the IP

 

 

address when printing. The values must be 4 numbers,

 

 

 

each between 0-255 (eg. 192.168.100.10).

 

WINS

 

Setting the WINS server (secondary) address. WINS

 

 

server will resolve the IP address from the host name.

 

 

 

 

 

Secondary Server

Therefore you can use a hostname instead of the IP

0.0.0.0

 

 

address when printing. The values must be 4 numbers,

 

 

 

each between 0-255 (eg. 192.168.100.10).

 

 

Scope ID

The scoop ID defines the computer group that

none

 

recognized the registered host name.

 

 

 

 

 

Setting of IP filter operations. Available options are

 

 

 

"allow" and "deny". If you select "allow", only the data

DENY

 

Filter Mode

from the set IP address range are accepted. If you

 

 

select "deny", the data from the set IP address range

 

 

 

cannot be received.

 

 

Filter #0 Start address

Setting IP filter range. IP addresses to be filtered can be

0.0.0.0

IP Filter Config

Filter #0 end address

set to maximum 4 address ranges. If address range

0.0.0.0

 

Filter #1 Start address

setting is not required, please enter the address range

0.0.0.0

 

Filter #1 end address

from "0.0.0.0" to "0.0.0.0".

0.0.0.0

 

Filter #2 Start address

 

0.0.0.0

 

Filter #2 end address

 

0.0.0.0

 

Filter #3 Start address

 

0.0.0.0

 

Filter #3 end address

 

0.0.0.0

-Communication from a designated range of IP addresses can be blocked when Filter Mode is set to “DENY.” On the other hand, when Filter Mode is set to “ALLOW,” communication from only a designated range of IP addresses can be enabled.

Appendix

37

Image 99
Contents WA01040XA ENG200501 Contents Scanner Server User Registration Introduction About this Manual Symbols used in this manualExpression Meaning Example of picture Safety InstructionsIntroduction Introduction Introduction Introduction Pricom C-6400W Emission Notice Operating Environment EnvironmentFollowings are objects that connect to the network Supported OSPart name and function Equipment explanationPricom C-6400W is initialized Start in Infrastructure mode How to Connect Connect the Pricom C-6400W to Printer and NetworkPricom C-6400W needs the following to connect to a network Make sure that printer is working and turned on Web Brower functionality Other FunctionsFunction Other functions of the Pricom C-6400W are shown belowIP Filter Scanner serverStorage server 8MByte SpecificationHardware specification V850 CPU 40MHz MemorySoftware Specification Do not use next to the following Using Wireless CommunicationWireless Equipment for 2.4GHz band Ad hoc mode Each wireless product connects directory Access Point 2PRICOM Setup 1Quick Setup GuideOnline manual 3Print Utility Setup4Scan Utility Setup Set up the Pricom USB Utility to use the scanner functionInfrastructure mode How to Communicate to the Pricom C-6400WProcedure for initial communication with the Pricom C-6400W Ad hoc modeSet up using the Pricom Setup Utility PC.Click Pricom SetupSelect Setup Pricom from PC by wireless LAN. Click Next Select the Pricom C-6400W in search list. Then click Next Click Yes if you agree toPage Check PRICOM-Print CX2, and click NextClick Next Select a folder to install to, and then click Next Click Start to start installing the PRICOM-Print CX2Select a Group name and click Next Pricom User Software CX2 Scanner Server Initial set up Connect the Pricom C-6400W and USB scanner6400W Ethernet Hub Canon MFP Install the Pricom USB Utility Use the Scanner ServerClick Next Click Yes, if you agree to Verify the installation folder, click Next Verify the Group name and clickClick Start Scanner Server Click Search Use the Pricom USB UtilityConnect your PC to the C-6400W. Click Connect Scanner Server Pricom USB Utility screen Pricom USB UtilityOption Dialog When changing mode from other users engaged to waiting When changing mode from waiting to connectingWhen changing mode from connecting to waiting When changing mode from waiting to other users engagedStorage Server 6400W Canon MFP Install the Pricom C-6400W and Canon MFPFor Microsoft Networks must be on your PC Select Start Settings Control PanelShare the Memory Card Via the Network Share the memory card in a Windows98/Me EnvironmentMicrosoft TCP/IP Click the memorycard on memory card folder Click the PRICOMs iconVerify that NetBEUI Protocol has been added Share the memory card in a Windows 2000 EnvironmentVerify that Client for Microsoft Networks has been addedVerify that Client for Microsoft Networks has been added Verify that Internet protocol TCP/IP has been installedClick My Network Places Entire Connect a memory card to the Canon MFPs card slotShare the memory card in a Windows XP environment Select start Control Panel Network ConnectionsOpen the properties of Local Area Connection Make sure Client for Microsoft Networks has been added Servers in workgroup Click the PRICOMs icon Main menu does not start after inserting the CD-ROM Pricom C-6400W is not found in the configuration utilityPricom -Print CX2 TCP Port Cannot printCannot print in LPR How can I return to factory default?Cannot configure in the AdHoc mode Occasionally I cannot printCannot use the scanner Cannot use Memory card via networkStart the Pricom User Software CX2 How to use USB memoryConfigure the TCP/IP parameters, click Connect the USB memory to the PC, click NextSelect the USB memory drive, click Appendix Check the LED status. Click Next Click Next Verify the install folder. Click Next Verify the group name, click Next Next Click Finish Write configuration information using an editor Appendix Using a standard OS print client Wizard to add a printer. Then click Settings Click Finish Select the printer driver. Click Next Page Select Yes to print a test print. Click Click Start Settings Control Panel Print using the Windows 2000 LPR portNext Next Appendix Go to start-Control Panel-Printers Print using the Windows XP LPR portAppendix Appendix Add wizard will appear Print Using the Windows 2000, Windows XP IPP portExample Select Connect to a printer onConnect to the Pricom C-6400W Connect to the Pricom C-6400W from a Web browserPrinter status is displayed as well as the printer name Set up parameters for the Pricom 6400W are displayedPricom C-6400W Http screen Printer StatusPrintServer Restart PrintServerIf you are done, select Yes, the Pricom 6400W is restarted Silex technology,Inc Factory DefaultIP filtering Following is an example of Telnet TelnetAn example of Configure General menu1 An example of Configure Wireless LAN menu2An example of Configure TCP/IP3 An example of IP Filter Config5 An example of Configure NetBEUI/NetBIOS6An example of WINS4 An example of executing system96-2 An example of Configure SNMP7An example of Display Status96 An example of executing prn196-1An example of executeing Reset Settings to Defaults97 An example of restarting Print Server Settings98An example of exiting Setting the Pricom C-6400W parameters Check and Verification of the Pricom C-6400WThis section explains the parameters in the Pricom C-6400W TCP/IP parameter Topic Explain Factory Default User Registration