FieldServer FS-8700-66 Gestatmboxplcstat Gestatmboxprivlvl, Gestatnonodes, Gestatconnectattempt

Page 23

Page 23 of 29FS-8700-66_GE-SNP Manual

Page 23 of 29

No

Message

Description

 

 

 

 

 

 

 

 

 

 

 

 

17

GE_STAT_MBOX_PLC_STAT

 

 

 

 

 

 

18

GE_STAT_MBOX_PRIV_LVL

 

 

 

 

 

 

 

 

If a poll for a SNP Node is received and

19

GE_STAT_NO_NODES

there are no Nodes defined or there is no

 

 

matching Node.

 

 

 

20

GE_STAT_CONNECT_ATTEMPT

Counts

the number

of time

a

connection

attempt is made

 

 

 

 

 

 

 

 

 

 

Counts the number of times the driver

21

GE_STAT_CONNECT_RESPONSE

responds to connection attempts when

 

 

acting as a Server

 

 

 

22

GE_STAT_CONNECT_NO_RESPONSE

Counts the number of connection attempts

that timed out.

 

 

 

 

 

 

Counts the number of connection and poll

23

DRV_DLL_CLIENT_SENDS_MSG

messages sent by the Client (whole

 

 

messages only)

 

 

 

 

 

Counts the number of simple ack/nak’s sent

 

 

by Client.

These

ack/nak’s indicate

24

DRV_DLL_CLIENT_SENDS_ACKNAK

messages if formatted correctly, however

 

 

the device can not necessarily respond to

 

 

the request.

 

 

 

 

25

DRV_DLL_CLIENT_SENDS_BYTES

Byte count includes ack/nak's sent and all

fragments and connection

 

 

 

 

 

 

26

DRV_DLL_SERVER_SENDS_MSG

 

 

 

 

 

 

27

DRV_DLL_SERVER_SENDS_ACKNAK

Same as for Client

 

 

 

28

DRV_DLL_SERVER_SENDS_BYTES

 

 

 

 

 

 

29

DRV_DLL_CLIENT_RCVS_MSG

Counts

ack/nak’s,

and

all

message

fragments excluding attach responses

 

 

30

DRV_DLL_CLIENT_RCVS_BYTES

Byte count from above messages

 

 

Counts message fragments and ack/nak’s

31

DRV_DLL_SERVER_RCVS_MSG

rcvd from Client but excludes Client

 

 

responses to Server fragments

 

32

DRV_DLL_SERVER_RCVS_BYTES

Byte count for above messages

 

33

DRV_DLL_TIMEOUT

Count of timeouts caused by no response

or ic_timeout at the DLL layer

 

 

 

 

 

 

34

DRV_DLL_ERROR

Count of the number of times that the DLL

layer went into an error state.

 

 

 

 

 

 

35

DRV_DLL_ERROR_CODE

The error code from the most recent DLL

error is stored here.

 

 

 

 

 

 

 

 

 

 

Corresponds

to slave driver

actions in

36

GE_STAT_DRV_ACT_NODE_OFFLINE_R

responding to a poll.

The polled Node is

 

 

offline.

 

 

 

 

 

 

 

Corresponds to slave driver actions in

37

GE_STAT_DRV_ACT_NO_MAPDESC_R

responding to a poll. There is no Map

Descriptor that can be used to process the

 

 

poll from the Client.

 

 

 

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 email: support@fieldServer.com

Image 23
Contents Applicability & Effectivity FS-8700-66 GE SNPTable of Contents 3 of 29FS-8700-66GE-SNP Manual Gesnp Description4 of 29FS-8700-66GE-SNP Manual 5 of 29FS-8700-66GE-SNP Manual Hardware ConnectionsFS-8917-01 From FieldServer 6 of 29FS-8700-66GE-SNP ManualGE Logicmaster 7 of 29FS-8700-66GE-SNP Manual8 of 29FS-8700-66GE-SNP Manual Configuring the FieldServer as a Gesnp ClientData Arrays/Descriptors SNP Client Side Connection Descriptors9 of 29FS-8700-66GE-SNP Manual Descriptor Client Side Node Descriptors10 of 29FS-8700-66GE-SNP Manual RDBC, WRBC, Wrbx11 of 29FS-8700-66GE-SNP Manual Driver Related Map Descriptor ParametersTiming Parameters 12 of 29FS-8700-66GE-SNP Manual Map Descriptor Example 1 Simple ReadMap Descriptor Example 2 Simple Write 13 of 29FS-8700-66GE-SNP Manual Map Descriptor Example 3 Handling Bits19200 Odd None Configuring the FieldServer as a Gesnp ServerServer Side Connection Descriptors 14 of 29FS-8700-66GE-SNP Manual15 of 29FS-8700-66GE-SNP Manual Server Side Node Descriptors16 of 29FS-8700-66GE-SNP Manual Driver Specific Map Descriptor Parameters17 of 29FS-8700-66GE-SNP Manual Tabler Map Descriptor Example18 of 29FS-8700-66GE-SNP Manual 19 of 29FS-8700-66GE-SNP Manual Appendix A. Troubleshooting TipsSNP9 Appendix B. Error Messages20 of 29FS-8700-66GE-SNP ManualPage 20 Edit the CSV, correct the problem and reset the FieldServer Appendix B.1. Driver Stats Gestatmboxplcstat Gestatmboxprivlvl DrvdlltimeoutDrvdllerror DrvdllerrorcodeGestatdrvactnakr GestatcdupdictimeoutGestatdrvactnodatar Gestatdrvactnonoder25 of 29FS-8700-66GE-SNP Manual Appendix C. Advanced Topics Appendix C.1. SNP Node Names26 of 29FS-8700-66GE-SNP Manual Minor Error Status CodesAppendix C.2. Scaling 27 of 29FS-8700-66GE-SNP Manual 0BD Minor Error Status Codes Program Load and Store Requests28 of 29FS-8700-66GE-SNP Manual 0BFThis page Intentionally Left Blank 29 of 29FS-8700-66GE-SNP Manual