FieldServer Appendix B. Error Messages, 20 of 29FS-8700-66GE-SNP ManualPage 20, SNP9

Page 20

Page 20 of 29FS-8700-66_GE-SNP ManualPage 20 of 29

Appendix B. Error Messages

Message

 

 

 

Explanation

SNP:#1 FYI. The MapDesc called

The length of the Map Descriptor defined to expose driver

<%s> is too short.

 

 

 

statistics must be at least 660.5

SNP:#2 FYI. You could have

You may safely ignore this message. Read Appendix B.1

used a MapDesc called <%s> to

for information on how to expose the driver’s

expose diagnostic info.

 

 

communication statistics using a Data Array.

 

 

 

 

 

The driver is required to use the larger of its own or the

SNP:#3 FYI. SNP device requires

PLC’s T1 (Inter message) timer. This message is

produced when the PLC returns a T1 timer that is larger

inter msg timer < timeout.

than the driver’s timeout. Using this timer will mean that

Nid=<%s>.

 

 

 

every message will timeout. Increase the timeout for the

 

 

 

 

 

 

 

 

 

 

Node, connection or Map Descriptor as appropriate.5

 

 

 

 

 

A connection request has been received for the Node

SNP:#4

Error.

Cant

emulate

named in the error message but this Node has not been

Node=<%s>

 

 

 

defined in the CSV file. The connection has not been

 

 

 

 

 

established.5

 

 

 

 

 

This could result from a corrupted message or it may

SNP:#5

Err.

Total

bytes

indicate an unexpected/unsupported aspect of the SNP

expected/rcvd=%d/%d

 

 

protocol. If the message occurs frequently, take a log and

 

 

 

 

 

report the error to FieldServer.

 

 

 

 

 

This message requires no action. It reports the T1 timer

SNP:#6 FYI. T1 timer set to

value selected by the slave in milliseconds. If the value is

<%ld> mSec.

 

 

 

large then this will slow the communications rate and you

 

 

 

 

 

may wish to reconfigure the slave.

SNP:#7 FYI. T1 timer reset to

This is the FieldServer slave reporting its T1 timer after a

<%ld> mSec.

 

 

 

Client has established a connection No action is required.

SNP:8 FYI. Subsequent connect

No action is required. A Client has attempted to re-

response ignored. NName=<%s>

establish a connection that is already open.

 

 

 

 

 

This message uses two lines of the error log. It is printed

 

 

 

 

 

when a slave declines a request. The major and minor

 

 

 

 

 

faults are reported. These numbers are printed in

SNP:9

Err. Device

declined

hexadecimal. See Appendix C.3 for further details. The

request.

Mjr=%x(h)

Min=%x(h)

message reports the Map Descriptor which generated the

Possible

Offending Poll

=<%s>

rejected poll, the data type, the address and the number of

addr=%d length=%d

 

 

elements being requested. Often this message will be the

 

 

 

 

 

result of a poll that requests data past the end of a PLC

 

 

 

 

 

data table or when the length is based on a bit count but

 

 

 

 

 

the poll actually requests bytes.5

SNP:10

Err.

Wrong

msg

This message is reported when the driver receives an

type=%d(h) mbox=%x(h)

 

unexpected SNP message. Record this information, take

 

a log and report the error to FieldServer.

 

 

 

 

 

5Edit the CSV, correct the problem and reset the FieldServer

FieldServer Technologies 1991 Tarob Court Milpitas, California 95035 USA Web:www.fieldServer.com Tel: (408) 262-2299 Fax: (408) 262-2296 Toll_Free: 888-509-1970 email: support@fieldServer.com

Image 20
Contents FS-8700-66 GE SNP Applicability & EffectivityTable of Contents Gesnp Description 3 of 29FS-8700-66GE-SNP Manual4 of 29FS-8700-66GE-SNP Manual Hardware Connections 5 of 29FS-8700-66GE-SNP Manual6 of 29FS-8700-66GE-SNP Manual FS-8917-01 From FieldServer7 of 29FS-8700-66GE-SNP Manual GE Logicmaster8 of 29FS-8700-66GE-SNP Manual Configuring the FieldServer as a Gesnp ClientData Arrays/Descriptors SNP Client Side Connection Descriptors9 of 29FS-8700-66GE-SNP Manual Client Side Node Descriptors 10 of 29FS-8700-66GE-SNP ManualRDBC, WRBC, Wrbx Descriptor11 of 29FS-8700-66GE-SNP Manual Driver Related Map Descriptor ParametersTiming Parameters 12 of 29FS-8700-66GE-SNP Manual Map Descriptor Example 1 Simple ReadMap Descriptor Example 2 Simple Write Map Descriptor Example 3 Handling Bits 13 of 29FS-8700-66GE-SNP ManualConfiguring the FieldServer as a Gesnp Server Server Side Connection Descriptors14 of 29FS-8700-66GE-SNP Manual 19200 Odd NoneServer Side Node Descriptors 15 of 29FS-8700-66GE-SNP ManualDriver Specific Map Descriptor Parameters 16 of 29FS-8700-66GE-SNP Manual17 of 29FS-8700-66GE-SNP Manual Tabler Map Descriptor Example18 of 29FS-8700-66GE-SNP Manual Appendix A. Troubleshooting Tips 19 of 29FS-8700-66GE-SNP ManualSNP9 Appendix B. Error Messages20 of 29FS-8700-66GE-SNP ManualPage 20 Edit the CSV, correct the problem and reset the FieldServer Appendix B.1. Driver Stats Drvdlltimeout DrvdllerrorDrvdllerrorcode Gestatmboxplcstat GestatmboxprivlvlGestatcdupdictimeout GestatdrvactnodatarGestatdrvactnonoder GestatdrvactnakrAppendix C. Advanced Topics Appendix C.1. SNP Node Names 25 of 29FS-8700-66GE-SNP Manual26 of 29FS-8700-66GE-SNP Manual Minor Error Status CodesAppendix C.2. Scaling 27 of 29FS-8700-66GE-SNP Manual Minor Error Status Codes Program Load and Store Requests 28 of 29FS-8700-66GE-SNP Manual0BF 0BD29 of 29FS-8700-66GE-SNP Manual This page Intentionally Left Blank